Tear Film Characteristics During Wear of Daily Disposable Contact Lenses

被引:16
作者
Montani, Giancarlo [1 ]
Martino, Maurizio [1 ]
机构
[1] CERCA Univ Salento, Dipartimento Matemat & Fis Ennio De Giorgi, Via Arnesano, I-73100 Lecce, Italy
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
nesofilcon A; delefilcon A; stenfilcon A; quality of vision; pre-lens tear film stability; tear osmolarity; tear meniscus height; MENISCUS HEIGHT; RISK-FACTORS; HYDROGEL; DISCOMFORT; SURFACE; DEHYDRATION; PERFORMANCE; QUALITY;
D O I
10.2147/OPTH.S242422
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate changes induced over time by three daily disposable (DD) contact lenses on tear meniscus height (TMH), pre-lens non-invasive break-up time (pre-lens NIBUT), tear film osmolarity (TO) and objective quality of vision (OQV). Patients and Methods: Forty-six subjects enrolled in this prospective open-label unmasked non-randomized simultaneous comparative cross-over study. For the first week of the study, subjects wore a nesofilcon A lens in the right eye and a delefilcon A lens in the left eye. After 3 days of washout, for the second week, subjects wore a nesofilcon A lens in the left eye and a stenfilcon A lens in the right eye. TMH, pre-lens NIBUT, TO and OQV were measured before contact lens fitting and for each contact lens combination on day 1 at 20 minutes and on day 7 after >= 8 hours of wear. OQV measurement included the changes of objective scatter index (OSI), the stability index (SI) and the fluctuation index (FI) calculated in a range of time of 20 s from a blink. Results: TMH was unchanged at 20 minutes wear of all lenses but was significantly reduced after 8 or more hours wear (on day 7) of delefilcon A and stenfilcon A, respectively. Pre-lens NIBUT was significantly reduced with all lenses, while no significant change in TO was observed with any lens. SI and FI increased significantly for all lenses at both wear times. Conclusion: While the presence of any contact lens on the eye challenges the tear film, nesofilcon A contact lenses, despite their high water content, compared to delefilcon A and stenfilcon A contact lenses, showed a lower overall effect. We speculate that superior tear film behavior while wearing nesofilcon A lenses may translate to improved subjective comfort, but this remains to be evaluated.
引用
收藏
页码:1521 / 1531
页数:11
相关论文
共 52 条
[11]   Assessment of corneal thickness and tear meniscus during contact-lens wear [J].
Del Aguila-Carrasco, Antonio J. ;
Ferrer-Blasco, Teresa ;
Garcia-Lazaro, Santiago ;
Esteve-Taboada, Jose J. ;
Montes-Mico, Robert .
CONTACT LENS & ANTERIOR EYE, 2015, 38 (03) :185-193
[12]   Tear film evaluation and management in soft contact lens wear: a systematic approach [J].
Downie, Laura E. ;
Craig, Jennifer P. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (05) :438-458
[13]   The Impact of Contemporary Contact Lenses on Contact Lens Discontinuation [J].
Dumbleton, Kathy ;
Woods, Craig A. ;
Jones, Lyndon W. ;
Fonn, Desmond .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01) :93-99
[14]   The TFOS International Workshop on Contact Lens Discomfort: Report of the Contact Lens Interactions With the Ocular Surface and Adnexa Subcommittee [J].
Efron, Nathan ;
Jones, Lyndon ;
Bron, Anthony J. ;
Knop, Erich ;
Arita, Reiko ;
Barabino, Stefano ;
McDermott, Alison M. ;
Villani, Edoardo ;
Willcox, Mark D. P. ;
Markoulli, Maria .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (11) :98-122
[15]   EFFECT OF HYDROGEL LENS WEAR ON TEAR FILM STABILITY [J].
FABER, E ;
GOLDING, TR ;
LOWE, R ;
BRENNAN, NA .
OPTOMETRY AND VISION SCIENCE, 1991, 68 (05) :380-384
[16]   Agreement and repeatability of objective systems for assessment of the tear film [J].
Fernandez, Joaquin ;
Rodriguez-Vallejo, Manuel ;
Martinez, Javier ;
Tauste, Ana ;
Garcia-Montesinos, Javier ;
Pinero, David P. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 256 (08) :1535-1541
[17]   Targeting contact lens induced dryness and discomfort: What properties will make lenses more comfortable [J].
Fonn, Desmond .
OPTOMETRY AND VISION SCIENCE, 2007, 84 (04) :279-285
[18]   Qualitative and quantitative characterization of the In Vitro dehydration process of hydrogel contact lenses [J].
Gonzalez-Meijome, Jose M. ;
Lopez-Alemany, Antonio ;
Almeida, Jose B. ;
Parafita, Manuel A. ;
Refojo, Miguel F. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 83B (02) :512-526
[19]   Clinical performance and "ex vivo" dehydration of silicone hydrogel contact lenses with two new multipurpose solutions [J].
Gonzalez-Meijome, Jose Manuel ;
da Silva, Ana Carla ;
Neves, Helena ;
Lopes-Ferreira, Daniela ;
Queiros, Antonio ;
Jorge, Jorge .
CONTACT LENS & ANTERIOR EYE, 2013, 36 (02) :86-92
[20]   Dry Eye Symptomatology of Soft Contact Lens Wearers and Nonwearers [J].
Guillon, Michel ;
Maissa, Cecile .
OPTOMETRY AND VISION SCIENCE, 2005, 82 (09) :829-834