Long-term Arrhythmia Variability after Monomorphic Ventricular Tachycardia in Patients with an Implantable Cardioverter Defibrillator

被引:3
作者
Clemens, Marcell [1 ]
Nagy-Balo, Edina [1 ]
Herczku, Csaba [1 ]
Kun, Csaba [1 ]
Edes, Istvan [1 ]
Csanadi, Zoltan [1 ]
机构
[1] Univ Debrecen, Dept Cardiol, H-4032 Debrecen, Hungary
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2011年 / 34卷 / 10期
关键词
implantable cardioverter defibrillator; ventricular tachycardia; cycle length; intracardiac electrogram; index arrhythmia; CORONARY-ARTERY DISEASE; CATHETER ABLATION; SHOCKS; TRIAL; CONFIGURATIONS; ELECTROGRAMS;
D O I
10.1111/j.1540-8159.2011.03139.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Arrhythmia burden in patients receiving an implantable cardioverter defibrillator (ICD) after monomorphic ventricular tachycardia (mVT) is higher than in patients with other indications. We investigated the long-term arrhythmia profile in this subset of patients. Methods: Fifty-two patients with an ICD implanted after mVT were followed up for at least 3 months. The cycle lengths (CLs) of the tachycardias recovered from the device memory were compared with the CL of the index arrhythmia. Morphological analysis of the intracardiac electrograms was performed and the response to antitachycardia pacing (ATP) was also assessed. Results: A total of 833 mVT episodes with intracardiac electrograms occurred during the follow-up (3-58 months; mean: 30.3 months) in 41 of the 52 patients analyzed. mVTs with different CLs as compared with the index mVT were found in 26 (50.0%), and at least two different mVT morphologies were observed in 28 (53.8%) patients. Multiple mVT morphologies were predictive of lower ATP efficacy (95.6%, 85.0%, and 70.3% in the patients with 1, 2, and 3 or more mVT morphologies, respectively; P < 0.0001) and a higher shock burden (4.2%, 19.3%, and 24.7% in the patients with 1, 2, and 3 or more mVT morphologies, respectively; P < 0.0001). Conclusion: A high mVT burden was demonstrated with marked variability of the arrhythmias as concerns both CL and morphology in patients with an ICD implanted for mVT. Multiple mVT morphologies during the follow-up were predictive of lower ATP efficacy and a higher shock burden. (PACE 2011; 34:1185-1191)
引用
收藏
页码:1185 / 1191
页数:7
相关论文
共 19 条
  • [1] Effect of first ventricular tachycardia cycle length on rate of ventricular arrhythmia recurrence in patients with implantable cardioverter-defibrillator
    Arya, Arash
    Haghjoo, Majid
    Nikoo, Mohammad Hosein
    Dehghani, Mohammad Reza
    Fazelifar, Amir Farjam
    Sadr-Ameli, Mohammad Ali
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2006, 39 (04) : 404 - 408
  • [2] Ventricular tachycardias above the initially programmed tachycardia detection interval in patients with implantable cardioverter-defibrillators -: Incidence, prediction and significance
    Bänsch, D
    Castrucci, M
    Böcker, D
    Breithardt, G
    Block, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (02) : 557 - 565
  • [3] Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.hrthm.2008.04.014, 10.1016/j.jacc.2008.05.007]
  • [4] LONG-TERM REPRODUCIBILITY OF VENTRICULAR-TACHYCARDIA INDUCTION IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - SERIAL NONINVASIVE STUDIES
    GILLIS, AM
    SHELDON, RS
    WYSE, G
    LEITCH, JW
    YEE, R
    KLEIN, GJ
    DUFF, HJ
    MITCHELL, LB
    [J]. CIRCULATION, 1995, 91 (10) : 2605 - 2613
  • [5] Long-term outcome of patients who received implantable cardioverter defibrillators for stable ventricular tachycardia
    Glikson, M
    Lipchenca, I
    Viskin, S
    Ballman, KV
    Trusty, JM
    Gurevitz, OT
    Luria, DM
    Eldar, M
    Hammill, SC
    Friedman, PA
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (06) : 658 - 664
  • [6] RADIOFREQUENCY CATHETER ABLATION OF SUSTAINED VENTRICULAR-TACHYCARDIA IN IDIOPATHIC DILATED CARDIOMYOPATHY
    KOTTKAMP, H
    HINDRICKS, G
    CHEN, X
    BRUNN, J
    WILLEMS, S
    HAVERKAMP, W
    BLOCK, M
    BREITHARDT, G
    BORGGREFE, M
    [J]. CIRCULATION, 1995, 92 (05) : 1159 - 1168
  • [7] Catheter ablation of stable ventricular tachycardia before defibrillator implantation in patients with coronary heart disease (VTACH): a multicentre randomised controlled trial
    Kuck, Karl-Heinz
    Schaumann, Anselm
    Eckardt, Lars
    Willems, Stephan
    Ventura, Rodolfo
    Delacretaz, Etienne
    Pitschner, Heinz-Friedrich
    Kautzner, Josef
    Schumacher, Burghard
    Hansen, Peter S.
    [J]. LANCET, 2010, 375 (9708) : 31 - 40
  • [8] MORPHOLOGICALLY DISTINCT SUSTAINED VENTRICULAR TACHYCARDIAS IN CORONARY-ARTERY DISEASE - SIGNIFICANCE AND SURGICAL RESULTS
    MILLER, JM
    KIENZLE, MG
    HARKEN, AH
    JOSEPHSON, ME
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (06) : 1073 - 1079
  • [9] MULTIPLE MONOMORPHIC VENTRICULAR-TACHYCARDIA CONFIGURATIONS PREDICT FAILURE OF ANTIARRHYTHMIC DRUG-THERAPY GUIDED BY ELECTROPHYSIOLOGIC STUDY
    MITRANI, RD
    BIBLO, LA
    CARLSON, MD
    GATZOYLIS, KA
    HENTHORN, RW
    WALDO, AL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) : 1117 - 1122
  • [10] Relation of induced to spontaneous ventricular tachycardia from analysis of stored far-field implantable defibrillator electrograms
    Monahan, KM
    Hadjis, T
    Hallett, N
    Casavant, D
    Josephson, ME
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (03) : 349 - 353