Real-time geometric lens distortion correction using a graphics processing unit

被引:26
作者
Van der Jeught, Sam [1 ]
Buytaert, Jan A. N. [1 ]
Dirckx, Joris J. J. [1 ]
机构
[1] Univ Antwerp, Lab Biomed Phys, B-2020 Antwerp, Belgium
关键词
graphics processing unit; distortion correction; MODELS;
D O I
10.1117/1.OE.51.2.027002
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical imaging systems often suffer from distortion artifacts which impose important limitations on the direct interpretation of the images. It is possible to correct for these aberrations through image processing, but due to their calculation-intensive nature, the required corrections are typically performed offline. However, with image-based applications that operate interactively, real-time correction of geometric distortion artifacts can be vital. We propose a new method to generate undistorted images by implementing the required distortion correction algorithm on a commercial graphics processing unit (GPU), distributing the necessary calculations to many stream processors that operate in parallel. The proposed technique is not limited to affine lens distortions but allows for the correction of arbitrary geometric image distortion artifacts through individual pixel resampling at display rates of more than 30 frames per second for fully processed images (1024 x 768 pixels). Our method enables real-time GPU-based geometric lens distortion correction without the need for additional digital image processing hardware. (c) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.OE.51.2.027002]
引用
收藏
页数:5
相关论文
共 10 条
[1]  
[Anonymous], 2006, CUDA ZONE
[2]  
[Anonymous], 2005, CAM CAL TOOLB MATL
[3]  
Bax M., 2002, REAL TIME LENS DISTO, P9
[4]  
DeBry D, 2002, ACM T GRAPHIC, V21, P763, DOI 10.1145/566570.566649
[5]  
Gribbon K., 2003, IMAGE VISION COMPUT, P408
[6]   Videoendoscopic distortion correction and its application to virtual guidance of endoscopy [J].
Helferty, JP ;
Zhang, C ;
McLennan, G ;
Higgins, WE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (07) :605-617
[7]   Closed-loop phase stepping in a calibrated fiber-optic fringe projector for shape measurement [J].
Moore, AJ ;
McBride, R ;
Barton, JS ;
Jones, JDC .
APPLIED OPTICS, 2002, 41 (16) :3348-3354
[8]  
Ruijters Daniel, 2008, Proceedings of the Tenth IASTED International Conference on Computer Graphics and Imaging, P117
[9]   CORRECTION OF DISTORTION IN ENDOSCOPE IMAGES [J].
SMITH, WE ;
VAKIL, N ;
MAISLIN, SA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :117-122
[10]   CAMERA CALIBRATION WITH DISTORTION MODELS AND ACCURACY EVALUATION [J].
WENG, JY ;
COHEN, P ;
HERNIOU, M .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (10) :965-980