CFD simulation of wet cooling towers

被引:108
|
作者
Al-Waked, R
Behnia, M
机构
[1] Bassett Appl Res, Sydney, NSW 2060, Australia
[2] Univ Sydney, Sydney, NSW 2006, Australia
基金
澳大利亚研究理事会;
关键词
cooling tower; crosswind effect; two-phase flow; thermal performance; CFD;
D O I
10.1016/j.applthermaleng.2005.06.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat and mass transfer inside a natural draft wet cooling tower (NDWCT) have been investigated numerically under different operating and crosswind conditions. The three-dimensional CFD model has utilized the standard k-epsilon turbulence model as the turbulence closure. The current simulation has adopted both the Eulerian approach for the air phase and the Lagrangian approach for the water phase. The film nature of the water flow in the fill zone has been approximated by droplets flow with a given velocity. The required heat and mass transfer have been achieved by controlling the droplet velocity. At that specific droplet velocity, effects of the following operating parameters on the thermal performance of the NDWCT have been investigated: droplet diameter, inlet water temperature, number of nozzles, water flow rate and number of tracks per nozzle. As a result, the effect of crosswind velocity on the thermal performance has been found to be significant. Crosswinds with velocity magnitude higher than 7.5 m/s have enhanced the thermal performance of the NDWCT. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:382 / 395
页数:14
相关论文
共 50 条
  • [41] DETERMINATION OF INDUSTRIAL DIMENSIONS AND EMISSION OF WET COOLING-TOWERS
    BAER, E
    DITTRICH, H
    ERNST, G
    ROLLER, W
    WURZ, W
    BRENNSTOFF-WARME-KRAFT, 1980, 32 (02): : 69 - 70
  • [42] Numerical Modelling of Natural Draft Wet-Cooling Towers
    Adam Klimanek
    Archives of Computational Methods in Engineering, 2013, 20 : 61 - 109
  • [44] Energy and exergy analysis of counter flow wet cooling towers
    Saravanan, M.
    Saravanan, R.
    Renganarayanan, S.
    THERMAL SCIENCE, 2008, 12 (02): : 69 - 78
  • [45] Energy Balance and Energy Transfer in Wet Cooling Towers.
    Klenke, W.
    Brennstoff-Waerme-Kraft, 1977, 29 (05): : 198 - 206
  • [46] Numerical Modelling of Natural Draft Wet-Cooling Towers
    Klimanek, Adam
    ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING, 2013, 20 (01) : 61 - 109
  • [47] Mathematical simulation of the evaporational cooling of water films in cooling towers
    Inst Teplo i Massoobmena im. A.V., Lykova AN Belarusii, Minsk, Belarus
    Jiqiren, 6 (43-49):
  • [48] Development and validation of a CFD model for numerical simulation of a large natural draft wet cooling tower
    Blain, Nicolas
    Belaud, Antoine
    Miolane, Matthieu
    APPLIED THERMAL ENGINEERING, 2016, 105 : 953 - 960
  • [49] MICROBIAL EMISSION, IMMISSION AND CHANGES IN THE GERM COUNT IN THE COOLING WATER DURING OPERATION OF WET COOLING-TOWERS .4. MICROBIAL IMMISSION IN THE VICINITY OF WET COOLING-TOWERS
    BOTZENHART, K
    EGLER, W
    ATTAR, Y
    ERNST, G
    FISCHER, P
    KRIZEK, L
    WURZ, D
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1979, 169 (1-2): : 164 - 205
  • [50] A simulation software for cooling towers optimal operation
    Damian, M
    Motoiu, I
    Caracasian, L
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL. 60, PTS I & II, 1998, : 287 - +