被引:3
作者
Koehler, Klemens W. [1 ]
Losert, Heidrun [1 ]
Myklebust, Helge [2 ]
Nysaether, Jon [2 ]
Fleischhackl, Roman [1 ]
Sodeck, Gottfried [1 ]
Sterz, Fritz [1 ]
Herkner, Harald [1 ]
机构
[1] Med Univ Vienna, Gen Hosp Vienna, Dept Emergency Med, Vienna, Austria
[2] Laerdal Med, Stavanger, Norway
关键词
airway management; cardiopulmonary resuscitation (CPR); intubation; orotracheal intubation; respiration; artificial; transthoracic impedance;
D O I
10.1016/j.resuscitation.2007.12.016
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aim of the study: Endotracheal intubation is the preferred method to ensure proper artificial ventilation. Early detection of esophageal intubation is important for an individual patient's outcome. The aim of the study was to see if impedance measurements can be used to detect esophageal intubation, using the impedance measurement system of an experimental defibrillator. Materials and methods: Patients who died at the emergency department of a tertiary care hospital were eligible to be studied. After death was declared, patients were ventilated with a predefined tidal volume alternately via the conventional tracheal tube and via an additionally tube placed into the esophagus. The lowest and respectively highest median impedance amplitude for the first three ventilations was used as cut-off to calculate predictive values. Results: We enrolled 10 patients (mean age 65 years (S.D. 14), 7 mate) of whom 9 underwent CPR prior to death, 30% of the patients had a BMI > 30. Severe tung-edema was present in 2 cases. The lowest tracheal. impedance value was 0.736 Omega and the highest esophageal was 0.496 Omega. A ROC curve for this individualised approach gave an area under the curve of 1 (95% CI 0.001, 0.249). Conclusion: There is a large and significant reduction in transthoracic impedance when the tube is malpositioned in the esophagus. It may therefore be feasible to detect malintubation via thoracic impedance changes as an aid to improve the survival of critical ill patients. Further investigations on a larger population are needed. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:339 / 344
页数:6
相关论文
共 21 条
[1]   Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest [J].
Abella, BS ;
Alvarado, JP ;
Myklebust, H ;
Edelson, DP ;
Barry, A ;
O'Hearn, N ;
Vanden Hoek, TL ;
Becker, LB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (03) :305-310
[2]  
ATZLER E., 1932, ARBEITSPHYSIOLOGIE, V5, P636
[3]   USE OF ELECTRICAL IMPEDANCE TECHNIQUES FOR MONITORING OF RESPIRATORY PATTERN DURING ANAESTHESIA [J].
BAKER, LE ;
HILL, DW .
BRITISH JOURNAL OF ANAESTHESIA, 1969, 41 (01) :2-&
[4]   Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation [J].
Bozeman, WP ;
Hexter, D ;
Liang, HK ;
Kelen, GD .
ANNALS OF EMERGENCY MEDICINE, 1996, 27 (05) :595-599
[5]   Portable devices used to detect endotracheal intubation during emergency situations: A review [J].
Cardoso, MMSC ;
Banner, MJ ;
Melker, RJ ;
Bjoraker, DG .
CRITICAL CARE MEDICINE, 1998, 26 (05) :957-964
[6]   Measurement of tidal volume by using transthoracic impedance variations in rats [J].
Davidson, KG ;
Bersten, AD ;
Nicholas, TE ;
Ravenscroft, PR ;
Doyle, IR .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) :759-766
[7]  
Frakes Michael A, 2002, Air Med J, V21, P29, DOI 10.1016/S1067-991X(02)70022-9
[8]   Comparison of three different methods to confirm tracheal tube placement in emergency intubation [J].
Grmec, S .
INTENSIVE CARE MEDICINE, 2002, 28 (06) :701-704
[9]   Misplaced endotracheal tubes by paramedics in an urban emergency medical services system [J].
Katz, SH ;
Falk, JL .
ANNALS OF EMERGENCY MEDICINE, 2001, 37 (01) :32-37
[10]   Uniform reporting of measured quality of cardiopulmonary resuscitation (CPR) [J].
Kramer-Johansen, Jo ;
Edelson, Dana P. ;
Losert, Heidrun ;
Koehler, Klemens ;
Abella, Benjamin S. .
RESUSCITATION, 2007, 74 (03) :406-417