Initial patient imaging with an optimised radiotherapy beam for portal imaging

被引:12
作者
Flampouri, S
McNair, HA
Donovan, EM
Evans, PM
Partridge, M
Verhaegen, F
Nutting, CM
机构
[1] Inst Canc Res, Joint Phys Dept, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Joint Phys Dept, Sutton SM2 5PT, Surrey, England
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
[5] Royal Marsden NHS Trust, Dept Radiotherapy, Sutton, Surrey, England
[6] McGill Univ, Dept Med Phys, Montreal, PQ, Canada
[7] Royal Marsden NHS Trust, Head & Neck Unit, London, England
[8] Inst Canc Res, London SW3 6JB, England
关键词
portal imaging; low-Z target;
D O I
10.1016/j.radonc.2005.04.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To investigate the feasibility and the advantages of a portal-imaging mode on a medical accelerator, consisting of a thin low-Z bremsstrahlung target and a thin Gd2O2S/film detector, for patient imaging. Patients and methods: The international code of practice for high-energy photon dosimetry was used to calibrate dosimetry instruments for the imaging beam produced by 4.75 MeV electrons hitting a 6 mm thick aluminium target. Images of the head and neck of a humanoid phantom were taken with a mammography film system and the dose in the phantom was measured with TLDs calibrated for this beam. The first head and neck patient images are compared with conventional images (taken with the treatment beam on a film radiotherapy verification detector). Visibility of structures for six patients was evaluated. Results: Images of the head and neck of a humanoid phantom, taken with both imaging systems showed that the contrast increased dramatically for the new system while the dose required to form an image was less than 10(-2) Gy. The patient images taken with the new and the conventional systems showed that air-tissue interfaces were better defined in the new system image. Anatomical structures, visible on both films, are clearer with the new system. Additionally, bony structures, such as vertebrae, were clearly visible only with the new system. The system under evaluation was significantly better for all features in lateral images and most features in anterior images. Conclusions: This pilot study of the new portal imaging system showed the image quality is significantly improved. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 20 条
  • [1] Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors
    Berbeco, RI
    Jiang, SB
    Sharp, GC
    Chen, GTY
    Mostafavi, H
    Shirato, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02) : 243 - 255
  • [2] Optimal phosphor thickness for portal imaging
    Bissonnette, JP
    Cunningham, IA
    Munro, P
    [J]. MEDICAL PHYSICS, 1997, 24 (06) : 803 - 814
  • [3] Kilovision: Thermal modeling of a kilovoltage x-ray source integrated into a medical linear accelerator
    Cho, YB
    Munro, P
    [J]. MEDICAL PHYSICS, 2002, 29 (09) : 2101 - 2108
  • [4] Optimization of accelerator target and detector for portal imaging using Monte Carlo simulation and experiment
    Flampouri, S
    Evans, PM
    Verhaegen, F
    Nahum, AE
    Spezi, E
    Partridge, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (18) : 3331 - 3349
  • [5] LOW-ENERGY IMAGING WITH HIGH-ENERGY BREMSSTRAHLUNG BEAMS
    GALBRAITH, DM
    [J]. MEDICAL PHYSICS, 1989, 16 (05) : 734 - 746
  • [6] IAEA (International Atomic Energy Agency), 2000, TECHNICAL REPORT SER, V398
  • [7] Flat-panel cone-beam computed tomography for image-guided radiation therapy
    Jaffray, DA
    Siewerdsen, JH
    Wong, JW
    Martinez, AA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1337 - 1349
  • [8] Electronic and film portal images: A comparison of landmark visibility and review accuracy
    Kruse, JJ
    Herman, MG
    Hagness, CR
    Davis, BJ
    Garces, YI
    Haddock, MG
    Olivier, KR
    Stafford, SL
    Pisansky, TM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (02): : 584 - 591
  • [9] Krutman Y, 2002, PHYS MEDICA, V18, P55
  • [10] A MEGAVOLTAGE CT SCANNER FOR RADIOTHERAPY VERIFICATION
    LEWIS, DG
    SWINDELL, W
    MORTON, EJ
    EVANS, PM
    XIAO, ZR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) : 1985 - 1999