Global DIC approach guided by a cross-correlation based initial guess for HR-EBSD and on-axis HR-TKD

被引:23
作者
Ernould, Clement [1 ,2 ]
Beausir, Benoit [1 ,2 ]
Fundenberger, Jean-Jacques [1 ,2 ]
Taupin, Vincent [1 ,2 ]
Bouzy, Emmanuel [1 ,2 ]
机构
[1] Univ Lorraine, LEM3, CNRS, F-57000 Metz, France
[2] Univ Lorraine, Lab Excellence Design Alloy Met Low Mass Struct D, 7 Rue Felix Savart, Metz 57073, France
关键词
HR-EBSD; HR-TKD; On-axis TKD; Digital Image Correlation; Geometrically necessary dislocations; DIGITAL IMAGE CORRELATION; ELECTRON BACKSCATTER DIFFRACTION; TRANSMISSION KIKUCHI DIFFRACTION; ELASTIC STRAIN-MEASUREMENT; LATTICE ROTATIONS; ORIENTATION; DISLOCATION; DEFORMATION; ACCURACY; MISORIENTATIONS;
D O I
10.1016/j.actamat.2020.03.026
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Digital image correlation (DIC) techniques usually performed on deforming speckle patterns are applied here on electron diffraction patterns (EDP) in order to map disorientations with high angular resolution, as well as geometrically necessary dislocation densities and elastic strains. The proposed approach relies on a DIC analysis which is conducted independently from the microscope calibration. It registers EDP as a whole through a single and large region of interest whose relative deformation with respect to a reference EDP is described by a first-order homography. Subpixel registration is performed iteratively in the spatial domain using an inverse-compositional Gauss-Newton (IC-GN) algorithm which integrates the correction of the optical distortions. Its robustness against large orientation changes as well as its computational efficiency are improved by mean of an automated and path-independent initial guess which fairly captures the effects of large rotations on the EDP. Using successive Fourier-Mellin and Fourier transforms based cross-correlation techniques, the initial guess measures the in-plane rotation and translation between the reference and the target EDP, respectively. The performances of the technique are illustrated in markedly plastically deformed steels using two electron diffraction techniques in the scanning electron microscope. A 15% deformed interstitial free steel is investigated by means of electron backscattered diffraction (EBSD) while a quenched and tempered oxide dispersed strengthened steel subjected to martensitic transformation is characterized using a recently developed on-axis Transmission Kikuchi Diffraction (TKD) configuration. (C) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:131 / 148
页数:18
相关论文
共 70 条
[1]   ORIENTATION IMAGING - THE EMERGENCE OF A NEW MICROSCOPY [J].
ADAMS, BL ;
WRIGHT, SI ;
KUNZE, K .
METALLURGICAL TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1993, 24 (04) :819-831
[2]   A unified framework for polycrystal plasticity with grain boundary evolution [J].
Admal, Nikhil Chandra ;
Po, Giacomo ;
Marian, Jaime .
INTERNATIONAL JOURNAL OF PLASTICITY, 2018, 106 :1-30
[3]   Lucas-Kanade 20 years on: A unifying framework [J].
Baker, S ;
Matthews, I .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2004, 56 (03) :221-255
[4]  
Beausir B., 2017, Analysis Tools for Electron and X- Ray Diffraction
[5]   Space rocks and optimising scanning electron channelling contrast [J].
Ben Britton, T. ;
Goran, Daniel ;
Tong, Vivian S. .
MATERIALS CHARACTERIZATION, 2018, 142 :422-431
[6]   Ncorr: Open-Source 2D Digital Image Correlation Matlab Software [J].
Blaber, J. ;
Adair, B. ;
Antoniou, A. .
EXPERIMENTAL MECHANICS, 2015, 55 (06) :1105-1122
[7]   High resolution electron backscatter diffraction measurements of elastic strain variations in the presence of larger lattice rotations [J].
Britton, T. B. ;
Wilkinson, A. J. .
ULTRAMICROSCOPY, 2012, 114 :82-95
[8]   Measurement of residual elastic strain and lattice rotations with high resolution electron backscatter diffraction [J].
Britton, T. B. ;
Wilkinson, A. J. .
ULTRAMICROSCOPY, 2011, 111 (08) :1395-1404
[9]   Factors affecting the accuracy of high resolution electron backscatter diffraction when using simulated patterns [J].
Britton, T. B. ;
Maurice, C. ;
Fortunier, R. ;
Driver, J. H. ;
Day, A. P. ;
Meaden, G. ;
Dingley, D. J. ;
Mingard, K. ;
Wilkinson, A. J. .
ULTRAMICROSCOPY, 2010, 110 (12) :1443-1453
[10]   Diffraction contrast dependence on sample thickness and incident energy in on-axis Transmission Kikuchi Diffraction in SEM [J].
Brodu, E. ;
Bouzy, E. ;
Fundenberger, J. -J. .
ULTRAMICROSCOPY, 2017, 181 :123-133