Experimental Study and Calculation Methods of Shear Capacity for High-Strength Reinforced Concrete Full-Scale Deep Beams

被引:5
作者
Li, Shushan [1 ]
Wu, Ziwen [1 ]
Zhang, Junhong [1 ]
Xie, Wei [1 ]
机构
[1] North China Univ Water Resources & Elect Power, Sch Civil Engn & Commun, Zhengzhou 450046, Peoples R China
基金
中国国家自然科学基金;
关键词
deep beam; high-strength reinforcement; shear strength; shear span-to-depth ratio; strut-and-tie model; TIE MODEL; STRUT; PREDICTION; BEHAVIOR; REGIONS; DESIGN;
D O I
10.3390/ma15176017
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The shear behavior of 8 high-strength concrete full-scale deep beams with high-strength steel bars was studied. The depth beam size was 100 mm x 900 mm x 2200 mm, the test parameters included the shear span-to-depth ratio (lambda = 0.9, 0.6, 0.3), longitudinal reinforcement ratio (rho(s )= 0.66%, 1.06%, 1.26%) and stirrup reinforcement ratio (rho(sv) = 0, 0.26%, 0.34%, 0.5%). The ratio of the cracking load of the inclined section to the ultimate load is between 30% and 50%, and the bending deformation of the deep beam is small, showing the characteristics of brittle failure for deep beams. Under the action of a concentrated load, the failure mode of deep beams with a small shear span ratio is the failure of the diagonal compression struts, which is very different from that of shallow beams with a large shear span ratio. With the increase of shear span ratio from 0.3 to 0.9, the ultimate shear capacity of deep beams decreases by 19.33%. With the increase of longitudinal reinforcement ratio from 0.67% to 1.27%, the ultimate shear capacity of deep beams increased by 45.02%. With the increase of vertical stirrup reinforcement ratio from 0% to 0.5%, the ultimate shear capacity of deep beams increased by 8.93%. Increasing the area of longitudinal bars or stirrups limited the transverse tensile strain of the compression struts, which is conducive to improving the compressive strength of the compression struts of deep beams and then improving the bearing capacity of deep beams. The strut-and-tie model (STM) is more suitable for analyzing the shear capacity of deep beams. The calculation methods for calculating the shear capacity of deep beams were compared with ACI 318-19, CSA A23 3-19, EN 1992-1-1:2004, Tan-Tan model, Tan-Cheng model, softened STM (SSTM) and simplified SSTM (SSSTM). The results showed that the shear capacity of deep beams could be well predicted by reasonably determining the STM parameters.
引用
收藏
页数:22
相关论文
共 41 条
[1]  
[Anonymous], 2014, ACI 318--14, DOI DOI 10.14359/51716937
[2]  
[Anonymous], 2019, BUILDING CODE REQUIR
[3]   Shear Strength of Reinforced Concrete Simple and Continuous Deep Beams [J].
Chen, Hui ;
Yi, Wei-Jian ;
Ma, Zhongguo John ;
Hwang, Hyeon-Jong .
ACI STRUCTURAL JOURNAL, 2019, 116 (06) :31-40
[4]   Cracking strut-and-tie model for shear strength evaluation of reinforced concrete deep beams [J].
Chen, Hui ;
Yi, Wei-Jian ;
Hwang, Hyeon-Jong .
ENGINEERING STRUCTURES, 2018, 163 :396-408
[5]  
COOK WD, 1988, ACI STRUCT J, V85, P206
[6]  
CSA A23.3-19, 2019, DESIGN CONCRETE STRU
[7]   Parameters affecting diagonal cracking behavior of reinforced concrete deep beams [J].
Demir, Aydin ;
Caglar, Naci ;
Ozturk, Hakan .
ENGINEERING STRUCTURES, 2019, 184 :217-231
[8]  
Ding X., 2010, J. 872-2000
[9]  
Foster SJ, 1998, ACI STRUCT J, V95, P382
[10]  
GB/T50081-2002, 2002, STANDARD TEST METHOD