摘要
PURPOSE: To compare wavefront-guided and wavefront-optimized LASIK in patients with myopic astigmatism up to -7.00 diopters (D) sphere and 3.00 D cylinder. METHODS: In this prospective, comparative study, 41 patients had wavefront-guided LASIK in one eye and wavefront-optimized LASIK in the fellow eye. The LASIK flap was created with a Hansatome XP microkeratome (Bausch & Lomb). The ALLEGRETTO Concerto excimer laser (WaveLight Laser Technologie AG) was used for photoablation. Pupil centroid shift and cyclotorsion were not compensated in the wavefront-guided treatments. The ALLEGRETTO Wave analyzer was used to measure ocular wavefront aberrations, and the CSV-1000 instrument (VectorVision) was used to measure contrast sensitivity before and 1 and 3 months after LASIK. RESULTS: Preoperative mean spherical equivalent refraction was -4.25 +/- 1.19 D (range: -7.50 to -2.50 D) and -4.15 +/- 1.21 D (range: -7.13 to -1.75 D) in the wavefront-guided and wavefront-optimized groups, respectively. Three months postoperatively, 33 (89.2%) eyes in the wavefront-guided group and 31 (83.8%) eyes in the wavefront-optimized group had uncorrected distance visual acuity of 20/20. Higher order aberrations increased from 0.28 +/- 0.08 mu m (range: 0.13 to 0.48 mu m) and 0.26 +/- 0.08 mu m (range: 0.13 to 0.55 mu m) to 0.45 +/- 0.17 mu m (range: 0.18 to 0.71 mu m) and 0.45 +/- 0.16 mu m (range: 0.21 to 0.84 mu m) in the wavefront-guided and wavefront-optimized groups, respectively. Except for C6 trefoil (P=.006), all Zernike polynomials increased in both groups postoperatively with no statistical difference between groups in spherical aberration (P=.41), C7 coma (P=.67), C8 coma (P=.79), and trefoil (P=.82). Contrast sensitivity did not decrease in either group and no statistically significant differences between groups were noted. CONCLUSIONS: Higher order aberrations, especially spherical aberration, increasd approximately the same amount in both groups. [J Refract Surg. 2011; 27(4):245-250.] doi:10.3928/1081597X-20100812-02
引用
收藏
页码:245 / 250
页数:6
相关论文
共 50 条
  • [31] Comparison of short-term refractive surgery outcomes after wavefront-guided versus non-wavefront-guided LASIK
    Moussa, Sarah
    Dexl, Alois
    Krall, Eva Maria
    Dietrich, Marie
    Arlt, Eva-Maria
    Grabner, Guenther
    Ruckhofer, Josef
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (06) : 529 - 535
  • [32] A Randomized Comparative Study of Topography-Guided Versus Wavefront-Optimized FS-LASIK for Correcting Myopia and Myopic Astigmatism
    Zhang, Yu
    Chen, Yueguo
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (09) : 575 - 582
  • [33] SMILE, Topography-Guided LASIK, and Wavefront-Guided LASIK: Review of Clinical Outcomes in Premarket Approval FDA Studies
    Schallhorn, Julie M.
    Seifert, Stefanie
    Schallhorn, Steven C.
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (11) : 690 - 698
  • [34] Topography-Guided Versus Wavefront-Optimized LASIK for Myopia With and Without Astigmatism: A Meta-analysis
    Cheng, Shi-Ming
    Tu, Rui-Xue
    Li, Xi
    Zhang, Jia-Sheng
    Tian, Zhen
    Zha, Zhi-Wei
    Ruan, Kun-Wei
    Yu, A-Yong
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (10) : 707 - +
  • [35] Clinical outcomes of topography-guided versus wavefront-optimized LASIK for correction of myopia and compound myopic astigmatism
    Rani, Deeksha
    Khokhar, Sudarshan
    Rathod, Aishwarya
    Nathiya, Venkatesh
    Pujari, Amar
    Gupta, Tavish
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (11) : 1598 - 1604
  • [36] Wavefront-Guided Lasik for low to moderate myopia - CustomCornea® versus Zyoptix®
    Barreiro, Telma Pereira
    Forseto, Adriana dos Santos
    Leite Pinto, Lucila Ferreira
    Francesconi, Claudia Maria
    Nose, Walton
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (04) : 519 - 525
  • [37] Visual Outcomes After LASIK Using Topography-Guided vs Wavefront-Guided Customized Ablation Systems
    Toda, Ikuko
    Ide, Takeshi
    Fukumoto, Teruki
    Tsubota, Kazuo
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (11) : 727 - +
  • [38] Aspheric wavefront-guided versus wavefront-guided LASIK for myopic astigmatism with the Technolas 217z100 excimer laser
    Taneri, Suphi
    Oehler, Saskia
    MacRae, Scott M.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (02) : 609 - 616
  • [39] Comparison of Night Driving Performance after Wavefront-Guided and Conventional LASIK for Moderate Myopia
    Schallhorn, Steve C.
    Tanzer, David J.
    Kaupp, Sandor E.
    Brown, Mitch
    Malady, Stephanie E.
    OPHTHALMOLOGY, 2009, 116 (04) : 702 - 709
  • [40] Iris registration in wavefront-guided LASIK to correct mixed astigmatism
    Khalifa, Mounir
    El-Kateb, Mohamed
    Shaheen, Mohamed Shafik
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (03) : 433 - 437