Excimer laser photorefractive keratectomy for hyperopia: 7.5-year follow-up

被引:34
作者
O'Brart, DPS [1 ]
Patsoura, E [1 ]
Jaycock, P [1 ]
Rajan, M [1 ]
Marshall, J [1 ]
机构
[1] St Thomas Hosp, Dept Ophthalmol, London SE1 7EH, England
关键词
D O I
10.1016/j.jcrs.2004.10.051
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report the results of a long-term prospective study to evaluate refractive stability and safety of hyperopic photorefractive keratectomy (H-PRK). Setting: Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom. Methods: Twenty-one patients (49%) (40 eyes) of cohort of 43 patients who participated in 1 of the first clinical trials of H-PRK were assessed at a mean follow-up of 90.7 months (range 62 to 106 months). The H-PRK was performed using a Summit Technology Apex Plus Excimer laser (Summit Technology, Inc.). The mean preoperative spherical equivalent refraction (SEQ) was +4.70 diopters (D) (range +2.00 to +7.50 D). Patients were allocated to 1 of 4 treatment groups based on their preoperative refraction and received 1 of the following spherical corrections: +1.50 D, +3.00 D, +4.50 D, or +6.00 D. Results: At 7.5 years, the refractive correction remained stable with a mean difference in SEQ between 1 year and 7.5 years of +0.28 D. The mean manifest SEQ was +0.83 D (range +5.00 to -3.00 D). Sixty-seven percent of eyes having corrections of +1.50 D and +3.00 D were within +/- 1.00 D of the predicted correction. Predictability was poorer with +4.50 D and +6.00 D corrections, with 40% of eyes within +/- 1.00 D of that expected. An improvement in uncorrected near acuity was achieved in 35 eyes (87.5%), and 35 eyes (87.5%) showed an improvement in uncorrected distance acuity from preoperative levels. Best spectacle-corrected visual acuity (BSCVA) was unchanged or improved from preoperative values in 25 eyes (62.5%). Three eyes (8%) lost 2 lines of Snellen BSCVA, which in 2 cases was attributable to cataract formation. A peripheral ring of haze, 6.5 mm in diameter, appeared in most eyes. Its intensity was greatest at 6 months and then diminished with time. In 10 eyes (25%), remnants of the haze ring were evident at 7.5 years and subepithelial iron rings, 6.5 mm in diameter were evident in 26 eyes (70%). No patient complained of night-vision problems and no eye developed ectasia. Conclusions: In H-PRK, refractive stability achieved at 1 year was maintained up to 7.5 years with no evidence of hyperopic shift, diurnal fluctuation, or late regression. Peripheral corneal haze decreased with time but was still evident in a number of eyes at the last follow-up visit.
引用
收藏
页码:1104 / 1113
页数:10
相关论文
共 35 条
[1]  
American Academy of Ophthalmology, 1992, OPHTHALMOLOGY, V99, P1332
[2]   LASER CORRECTION OF HYPEROPIA AND PRESBYOPIA [J].
ANSCHUTZ, T .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 1994, 34 (04) :107-137
[3]   COMPLICATIONS OF HEXAGONAL KERATOTOMY [J].
BASUK, WL ;
ZISMAN, M ;
WARING, GO ;
WILSON, LA ;
BINDER, PS ;
THOMPSON, KP ;
GROSSNIKLAUS, HE ;
STULTING, RD .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 117 (01) :37-49
[4]   Refractive changes in the elderly [J].
Bengtsson, B ;
Grodum, K .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1999, 77 (01) :37-39
[5]  
Carones F, 2003, J REFRACT SURG, V19, P548
[6]  
DAUSCH D, 1993, REFRACT CORNEAL SURG, V9, P419
[7]  
DURRIE DS, 1994, J REFRACT CORNEAL S, V10, pS277
[8]  
Esquenazi S, 1999, J REFRACT SURG, V15, P648
[9]   Laser in situ keratomileusis: Literature review of a developing technique [J].
Farah, SG ;
Azar, DT ;
Gurdal, C ;
Wong, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (07) :989-1006
[10]  
Feldman S T, 1989, Refract Corneal Surg, V5, P288