The Evolution of Lateral Dose Distributions of Helium Ion Beams in Air: From Measurement and Modeling to Their Impact on Treatment Planning

被引:4
作者
Besuglow, Judith [1 ,2 ,3 ,4 ,5 ,6 ]
Tessonnier, Thomas [7 ]
Kopp, Benedikt [1 ,2 ,3 ,4 ,5 ]
Mein, Stewart [1 ,2 ,3 ,4 ,5 ]
Mairani, Andrea [1 ,2 ,7 ,8 ]
机构
[1] Heidelberg Univ Hosp UKHD, Natl Ctr Tumor Dis NCT, CoreCtr Heidelberg, Clin Cooperat Unit Translat Radiat Oncol,German C, Heidelberg, Germany
[2] German Canc Res Ctr, Heidelberg, Germany
[3] Heidelberg Univ Hosp, Div Mol & Translat Radiat Oncol, Heidelberg Fac Med MFHD, Heidelberg, Germany
[4] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
[5] Heidelberg Univ Hosp, Heidelberg Fac Med MFHD, Heidelberg Inst Radiat Oncol HIRO, Natl Ctr Radiat Oncol NCRO,Heidelberg Ion Beam Th, Heidelberg, Germany
[6] Heidelberg Univ, Dept Phys & Astron, Heidelberg, Germany
[7] Heidelberg Univ Hosp UKHD, Dept Radiat Oncol, Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
[8] Natl Ctr Oncol Hadrontherapy CNAO, Med Phys, Pavia, Italy
关键词
particle therapy; Monte Carlo simulation; Helium; treatment planning system; ion beam; lateral profiles; dosimetry; SCANNED PROTON; MULTIPLE-SCATTERING; CARBON-IONS; THERAPY; RADIOTHERAPY; SYSTEM; HE-4;
D O I
10.3389/fphy.2021.797354
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
To start clinical trials with the first clinical treatment planning system supporting raster-scanned helium ion therapy, a comprehensive database of beam characteristics and parameters was required for treatment room-specific beam physics modeling at the Heidelberg Ion-Beam Therapy Center (HIT). At six different positions in the air gap along the beam axis, lateral beam profiles were systematically measured for 14 initial beam energies covering the full range of available energies at HIT. The 2D-array of liquid-filled ionization chambers OCTAVIUS from PTW was irradiated by a pencil beam focused at the central axis. With a full geometric representation of HIT's monitoring chambers and beamline elements in FLUKA, our Monte Carlo beam model matches the measured lateral beam profiles. A second set of measurements with the detector placed in a water tank was used to validate the adjustments of the initial beam parameters assumed in the FLUKA simulation. With a deviation between simulated and measured profiles below +/- 0.8 mm for all investigated beam energies, the simulated profiles build part of the database for the first clinical treatment planning system for helium ions. The evolution of beamwidth was also compared to similar simulations of the clinically available proton and carbon beam. This allows a choice of treatment modality based on quantitative estimates of the physical beam properties. Finally, we investigated the influence of beamwidth variation on patient treatment plans in order to estimate the relevance and necessary precision limits for lateral beam width models.
引用
收藏
页数:14
相关论文
共 36 条
  • [11] An analytical model for light ion pencil beam dose distributions: multiple scattering of primary and secondary ions
    Hollmark, M.
    Gudowska, I.
    Belkic, Dz
    Brahme, A.
    Sobolevsky, N.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13) : 3477 - 3491
  • [12] Measurement of 4He charge- and mass-changing cross sections on H, C, O, and Si targets in the energy range 70-220 MeV/u for radiation transport calculations in ion-beam therapy
    Horst, Felix
    Arico, Giulia
    Brinkmann, Kai-Thomas
    Brons, Stephan
    Ferrari, Alfredo
    Haberer, Thomas
    Mairani, Andrea
    Parodi, Katia
    Reidel, Claire-Anne
    Weber, Uli
    Zink, Klemens
    Schuy, Christoph
    [J]. PHYSICAL REVIEW C, 2019, 99 (01)
  • [13] Rapid effective dose calculation for raster-scanning 4He ion therapy with the modified microdosimetric kinetic model (mMKM)
    Kopp, B.
    Mein, S.
    Tessonnier, T.
    Besuglow, J.
    Harrabi, S.
    Heim, E.
    Abdollahi, A.
    Haberer, T.
    Debus, J.
    Mairani, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 273 - 284
  • [14] Treatment planning for heavy-ion radiotherapy:: calculation and optimization of biologically effective dose
    Krämer, M
    Scholz, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) : 3319 - 3330
  • [15] Treatment planning for heavy-ion radiotherapy:: physical beam model and dose optimization
    Krämer, M
    Jäkel, O
    Haberer, T
    Kraft, G
    Schardt, D
    Weber, U
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) : 3299 - 3317
  • [16] DOSIMETRY AND INSTRUMENTATION FOR HELIUM AND HEAVY-IONS
    LYMAN, JT
    HOWARD, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 3 : 81 - 85
  • [17] MOLIERE G, 1955, Z NATURFORSCH PT A, V10, P177
  • [18] Are Further Cross Section Measurements Necessary for Space Radiation Protection or Ion Therapy Applications? Helium Projectiles
    Norbury, John W.
    Battistoni, Giuseppe
    Besuglow, Judith
    Bocchini, Luca
    Boscolo, Daria
    Botvina, Alexander
    Clowdsley, Martha
    de Wet, Wouter
    Durante, Marco
    Giraudo, Martina
    Haberer, Thomas
    Heilbronn, Lawrence
    Horst, Felix
    Kraemer, Michael
    La Tessa, Chiara
    Luoni, Francesca
    Mairani, Andrea
    Muraro, Silvia
    Norman, Ryan B.
    Patera, Vincenzo
    Santin, Giovanni
    Schuy, Christoph
    Sihver, Lembit
    Slaba, Tony C.
    Sobolevsky, Nikolai
    Topi, Albana
    Weber, Uli
    Werneth, Charles M.
    Zeitlin, Cary
    [J]. FRONTIERS IN PHYSICS, 2020, 8
  • [19] Ondreka D., 2008, C P C
  • [20] Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility
    Parodi, K.
    Mairani, A.
    Brons, S.
    Hasch, B. G.
    Sommerer, F.
    Naumann, J.
    Jaekel, O.
    Haberer, T.
    Debus, J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12) : 3759 - 3784