The Evolution of Lateral Dose Distributions of Helium Ion Beams in Air: From Measurement and Modeling to Their Impact on Treatment Planning

被引:4
作者
Besuglow, Judith [1 ,2 ,3 ,4 ,5 ,6 ]
Tessonnier, Thomas [7 ]
Kopp, Benedikt [1 ,2 ,3 ,4 ,5 ]
Mein, Stewart [1 ,2 ,3 ,4 ,5 ]
Mairani, Andrea [1 ,2 ,7 ,8 ]
机构
[1] Heidelberg Univ Hosp UKHD, Natl Ctr Tumor Dis NCT, CoreCtr Heidelberg, Clin Cooperat Unit Translat Radiat Oncol,German C, Heidelberg, Germany
[2] German Canc Res Ctr, Heidelberg, Germany
[3] Heidelberg Univ Hosp, Div Mol & Translat Radiat Oncol, Heidelberg Fac Med MFHD, Heidelberg, Germany
[4] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
[5] Heidelberg Univ Hosp, Heidelberg Fac Med MFHD, Heidelberg Inst Radiat Oncol HIRO, Natl Ctr Radiat Oncol NCRO,Heidelberg Ion Beam Th, Heidelberg, Germany
[6] Heidelberg Univ, Dept Phys & Astron, Heidelberg, Germany
[7] Heidelberg Univ Hosp UKHD, Dept Radiat Oncol, Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
[8] Natl Ctr Oncol Hadrontherapy CNAO, Med Phys, Pavia, Italy
关键词
particle therapy; Monte Carlo simulation; Helium; treatment planning system; ion beam; lateral profiles; dosimetry; SCANNED PROTON; MULTIPLE-SCATTERING; CARBON-IONS; THERAPY; RADIOTHERAPY; SYSTEM; HE-4;
D O I
10.3389/fphy.2021.797354
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
To start clinical trials with the first clinical treatment planning system supporting raster-scanned helium ion therapy, a comprehensive database of beam characteristics and parameters was required for treatment room-specific beam physics modeling at the Heidelberg Ion-Beam Therapy Center (HIT). At six different positions in the air gap along the beam axis, lateral beam profiles were systematically measured for 14 initial beam energies covering the full range of available energies at HIT. The 2D-array of liquid-filled ionization chambers OCTAVIUS from PTW was irradiated by a pencil beam focused at the central axis. With a full geometric representation of HIT's monitoring chambers and beamline elements in FLUKA, our Monte Carlo beam model matches the measured lateral beam profiles. A second set of measurements with the detector placed in a water tank was used to validate the adjustments of the initial beam parameters assumed in the FLUKA simulation. With a deviation between simulated and measured profiles below +/- 0.8 mm for all investigated beam energies, the simulated profiles build part of the database for the first clinical treatment planning system for helium ions. The evolution of beamwidth was also compared to similar simulations of the clinically available proton and carbon beam. This allows a choice of treatment modality based on quantitative estimates of the physical beam properties. Finally, we investigated the influence of beamwidth variation on patient treatment plans in order to estimate the relevance and necessary precision limits for lateral beam width models.
引用
收藏
页数:14
相关论文
共 36 条
  • [1] [Anonymous], 2015, Int J Particle Ther
  • [2] The FLUKA Code: Developments and Challenges for High Energy and Medical Applications
    Boehlen, T. T.
    Cerutti, F.
    Chin, M. P. W.
    Fosso, A.
    Ferrari, A.
    Ortega, P. G.
    Mairani, A.
    Sala, P. R.
    Smirnov, G.
    Vlachoudisl, V.
    [J]. NUCLEAR DATA SHEETS, 2014, 120 : 211 - 214
  • [3] Commissioning of pencil beam and Monte Carlo dose engines for non-isocentric treatments in scanned proton beam therapy
    Carlino, A.
    Boehlen, T.
    Vatnitsky, S.
    Grevillot, L.
    Osorio, J.
    Dreindl, R.
    Palmans, H.
    Stock, M.
    Kragl, G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (17)
  • [4] 15 years experience with helium ion radiotherapy for uveal melanoma
    Castro, JR
    Char, DH
    Petti, PL
    Daftari, IK
    Quivey, JM
    Singh, RP
    Blakely, EA
    Phillips, TL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (05): : 989 - 996
  • [5] RESULTS OF HEAVY-ION RADIOTHERAPY
    CASTRO, JR
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1995, 34 (01) : 45 - 48
  • [6] A GATE/Geant4 beam model for the MedAustron non-isocentric proton treatment plans quality assurance
    Elia, Alessio
    Resch, Andreas Franz
    Carlino, Antonio
    Boehlen, Till Tobias
    Fuchs, Hermann
    Palmans, Hugo
    Letellier, Virgile
    Dreindl, Ralf
    Osorio, Jhonnatan
    Stock, Markus
    Sarrut, David
    Grevillot, Loic
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 71 : 115 - 123
  • [7] A novel method for assessment of fragmentation and beam-material interactions in helium ion radiotherapy with a miniaturized setup
    Gallas, Raya R.
    Arico, Giulia
    Burigo, Lucas N.
    Gehrke, Tim
    Jakubek, Jan
    Granja, Carlos
    Turecek, Daniel
    Martisikova, Maria
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 116 - 126
  • [8] MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY
    HABERER, T
    BECHER, W
    SCHARDT, D
    KRAFT, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) : 296 - 305
  • [9] HIGHLAND VL, 1979, NUCL INSTRUM METHODS, V161, P171
  • [10] SOME PRACTICAL REMARKS ON MULTIPLE-SCATTERING
    HIGHLAND, VL
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1975, 129 (02): : 497 - 499