Review on the design modifications of a solar air heater for improvement in the thermal performance

被引:97
作者
Arunkumar, H. S. [1 ]
Karanth, K. Vasudeva [1 ]
Kumar, Shiva [1 ]
机构
[1] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Mech & Mfg Engn, Manipal 576104, India
关键词
Turbulator; Solar air heater; Reynold's number; Nusselt number; Friction factor; FRICTION FACTOR CORRELATIONS; TRANSFER ENHANCEMENT; NATURAL-GAS; ENTROPY GENERATION; THERMOHYDRAULIC PERFORMANCE; SUSTAINABLE DEVELOPMENT; ARTIFICIAL ROUGHNESS; RECTANGULAR DUCT; ENERGY STORAGE; RIB ROUGHNESS;
D O I
10.1016/j.seta.2020.100685
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar air heaters are widely used in various household and industrial applications. Reduced thermal efficiency of solar air heaters has necessitated the researchers to focus on the improvement of the thermal performance by providing artificial flow modification techniques in the flow field. As a result of this, laminar sublayer beneath the absorber plate will get disturbed and this helps to increase the turbulence level of the air. This results in increased heat transfer rate from the absorber plate. Paper discusses the influence of different shaped turbulators used by the various researchers in improving the thermal performance of air heaters. Design considerations, geometries used, flow conditions and their influence on turbulence, heat transfer rate, absorber temperature and thermo-hydraulic enhancement factor have been thoroughly discussed. Finally concluding remarks and the future scope for additional enhancement in the performance of solar air heater is proposed.
引用
收藏
页数:18
相关论文
共 76 条
[1]   Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater [J].
Aharwal, K. R. ;
Gandhi, B. K. ;
Saini, J. S. .
RENEWABLE ENERGY, 2008, 33 (04) :585-596
[2]  
[Anonymous], ASME 2013 INT MECH E
[3]  
[Anonymous], INT J NUMER METH HEA
[4]  
[Anonymous], INT J ENG TRENDS TEC
[5]  
[Anonymous], J SOLAR ENERGY ENG
[6]  
[Anonymous], J APPL COMPUT MECH
[7]  
Baissi MT, 2020, APPL THERM ENG, V165, DOI [10.1016/j.appithermaleng.2019.03.134, 10.1016/j.applthermaleng.2019.03.134]
[8]   Thermal analysis of three sides artificially roughened solar air heaters [J].
Behura, Arun Kumar ;
Rout, Sachindra Kumar ;
Pandya, Himanshu ;
Kumar, Ashiwini .
INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 :279-285
[9]   Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate [J].
Bhagoria, JL ;
Saini, JS ;
Solanki, SC .
RENEWABLE ENERGY, 2002, 25 (03) :341-369
[10]   Experimental investigations on heat transfer and frictional characteristics of a turbulator roughened solar air heater duct [J].
Bopche, Santosh B. ;
Tandale, Madhukar S. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (11-12) :2834-2848