SVC control retrofit - Example Clapham

被引:0
|
作者
Tyll, HK
Unterlass, FJ
机构
来源
2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS | 2003年
关键词
control systems; life extension; retrofit; Static Var compensators;
D O I
10.1109/PES.2003.1267199
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
More than 50000 MVars of controlled reactive power are installed worldwide in transmission systems since the early 70's. Many of them are faced to reach the expected end of their designed life-time and need refurbishment of various components. Some of them have already been up-graded and renewed in various aspects which are discussed briefly below. The paper describes the control retrofit of the Clapham SVC which was necessary mainly due to future lack of control system components. The new digital control should be based on the state of the art technology on one side and should also include a new control feature on the other side. Test and procedures necessary for the exchange and implementation are described.
引用
收藏
页码:366 / 369
页数:4
相关论文
共 50 条
  • [1] Clapham static VAr compensator control retrofit
    Stanley, E
    Hedin, R
    Renz, K
    Unterlass, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (03) : 889 - 894
  • [2] Hopf bifurcations induced by SVC controllers: A didactic example
    Gu, Wei
    Milano, Federico
    Jiang, Ping
    Tang, Guoqing
    ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (3-4) : 234 - 240
  • [3] SVC Adaptive Control Investigation
    Djagarov, Nikolay
    Grozdev, Zhivko
    Djagarova, Julia
    2017 IEEE 58TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2017,
  • [4] Influence of SVC location on subsynchronous oscillation and SVC control strategy research
    Zhao, Xin
    Gao, Shan
    Zhang, Ningyu
    Zhao, X. (fzhjct1@163.com), 1600, Chinese Society for Electrical Engineering (33): : 107 - 114
  • [5] Voltage control method by SVC in consideration of cooperative control with LRT and determination method for rated capacity and control parameters of SVC
    Kawasaki S.
    Hayashi Y.
    Matsuki J.
    Yamaguchi M.
    IEEJ Transactions on Power and Energy, 2010, 130 (11) : 963 - 971
  • [6] THE RETROFIT CHALLENGE IN NOX CONTROL
    MOORE, T
    EPRI JOURNAL, 1984, 9 (09): : 26 - 33
  • [7] AS/RS retrofit takes control
    Anon
    Modern Materials Handling, 2001, 56 (03)
  • [8] MOISTURE CONTROL IN RETROFIT INSULATION
    SHERWOOD, GE
    TRANSACTIONS OF THE ASAE, 1981, 24 (05): : 1296 - 1298
  • [9] Boiler control retrofit at convent
    Taillie, William P.
    ASHRAE Journal, 1998, 40 (11): : 56 - 58
  • [10] Retrofit for control and repairability of damage
    Dutta, Anindya
    Mander, John B.
    Kokorina, Tatiana
    Earthquake Spectra, 1999, 15 (04): : 657 - 679