Determination of carbon dioxide and acid components in exhaust gas by suppressed ion chromatography

被引:7
|
作者
Nonomura, M [1 ]
机构
[1] Tokyo Metropolitan Ind Technol Res Inst, Kita Ku, Tokyo 1158586, Japan
关键词
D O I
10.2116/analsci.20.219
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although anions are usually determined by suppressed ion chromatography (IC), carbonate and bicarbonate ions can not be determined, because a mixed solution of sodium carbonate and sodium hydrogencarbonate is used as the eluent. This paper describes an IC method for the determination of carbonate ion and common anions using an IonPac AG17/AS17 column, an EG 40 eluent generator and a conductivity detector. The proposed IC method could determine carbonate ion and anions within 6 min. The relative standard deviations (n = 5) for chloride (0.4 mg L-1), nitrite (0.8 mg L-1), carbonate (100 mg L-1), nitrate (1.0 mg L-1) and sulfate (2.0 mg L-1) ions were 5.1%, 1.1%, 4.2%, 5.1% and 1.1%, respectively. In addition, the absorbing solution of carbon dioxide was examined, and 2-amino-2-methyl-1-propanol was found to be a good absorbing solution. The proposed IC method was applied to the determination of carbon dioxide and acid components in flue gas and automobile exhaust gas.
引用
收藏
页码:219 / 222
页数:4
相关论文
共 50 条
  • [41] Determination of paracetamol in dosage forms by non-suppressed ion chromatography
    Pérez, JL
    Bello, MA
    TALANTA, 1999, 48 (05) : 1199 - 1202
  • [42] Determination of Tetrafluoroborate and Chloride Anions by Capillary Isotachophoresis and Suppressed Ion Chromatography
    Kosobucki, Przemyslaw
    Buszewski, Boguslaw
    CHEMIA ANALITYCZNA, 2008, 53 (06): : 895 - 903
  • [43] Determination of Phosphite in a Eutrophic Freshwater Lake by Suppressed Conductivity Ion Chromatography
    Han, Chao
    Geng, Jinju
    Xie, Xianchuan
    Wang, Xiaorong
    Ren, Hongqiang
    Gao, Shixiang
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (19) : 10667 - 10674
  • [44] Determination of Phytate and Phosphate in Plant Samples by Suppressed Conductivity Ion Chromatography
    Liu Qiaoru
    Dong Wenju
    Shi Qizeng
    Yang Guangrui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (03) : 302 - 304
  • [45] Simultaneous determination of inorganic anions, calcium and magnesium by suppressed ion chromatography
    García-Fernández, R
    García-Alonso, JI
    Sanz-Medel, A
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (01) : 127 - 133
  • [46] Effects of common metal ions on the determination of anions by suppressed ion chromatography
    Ding, YS
    Mou, S
    JOURNAL OF CHROMATOGRAPHY A, 2002, 956 (1-2) : 65 - 70
  • [47] Simultaneous determination of inorganic anions and metal ions by suppressed ion chromatography
    Bruzzoniti, MC
    Mentasti, E
    Sarzanini, C
    ANALYTICA CHIMICA ACTA, 1999, 382 (03) : 291 - 299
  • [48] SIMULTANEOUS DETERMINATION OF ARSENITE, ARSENATE, SELENITE, AND SELENATE BY SUPPRESSED ION CHROMATOGRAPHY
    MCGEEHAN, SL
    NAYLOR, DV
    JOURNAL OF ENVIRONMENTAL QUALITY, 1992, 21 (01) : 68 - 73
  • [49] The direct determination of urinary oxalate by non-suppressed ion chromatography
    Pfeiffer, K
    Berg, W
    Bongartz, D
    Hesse, A
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1997, 35 (04): : 305 - 308
  • [50] Determination of Inorganic Anions in Eucheuma cottonii and Carrageenan by Suppressed Ion Chromatography
    Suhaili, Refilda
    Munaf, Edison
    Zein, Rahmiana
    Sedyohutomo, Anang
    Lim, Lee Wah
    Takeuchi, Toyohide
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (06) : 2597 - 2599