Biomechanical Comparison of Tibial Nail Stability in a Proximal Third Fracture: Do Screw Quantity and Locked, Interlocking Screws Make a Difference?

被引:19
作者
Freeman, Andrew L. [1 ]
Craig, Matthew R. [2 ]
Schmidt, Andrew H. [3 ]
机构
[1] Excelen Ctr Bone & Joint Res & Educ, Minneapolis, MN 55415 USA
[2] Abington Mem Hosp, Abington, PA 19001 USA
[3] Hennepin Cty Med Ctr, Minneapolis, MN 55415 USA
关键词
proximal tibia fracture; intramedullary nail; locked screws; biomechanics; cyclic loading; SHAFT FRACTURES; LOCKING SCREWS; INTRAMEDULLARY; FIXATION; PLATE;
D O I
10.1097/BOT.0b013e3181f982e5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study compared the fatigue life of nailed proximal third tibial fractures stabilized with either three or four proximal screws using commercially available nails with both locked (through threaded holes or end caps) and nonlocked proximal interlocking screw configurations. Methods: Eight paired and two independent tibiae of known bone mineral density were acquired, divided into three groups, and implanted with three different commercially available nails (n = 6/group). Nails were all 10 mm in diameter and individually sized for length. Individual tibiae from a given pair received different nails. Based on nail design, Nail A received four proximal screws (three that lock into the nail), whereas Nails B and C each received three proximal nonlocking screws. Standard end caps were used with all nails. As a result of its design, in Nail B, the most proximal interlocking screw was "locked" by the nail end cap. All nails used two distal screws. After implantation, an unstable proximal third fracture was created and specimens were tested with combined axial and torsional loads of 40 to 400 N and 0.11 to 1.1 Nm for 500,000 cycles or until failure. Results: The fatigue life of Group A was significantly greater than either Groups B or C (P < 0.001 in both cases) with a mean cycle to failure of 392,977 versus 86,476 and 64,595 cycles for Nails B and C, respectively. Fatigue life of Group A was greater or equivalent to all contralateral tibiae; Group B outlasted all contralateral Group C limbs and the Group C constructs did not outlast any contralateral limbs. Bone mineral density correlated positively and significantly with fatigue life across all three groups (P < 0.001). Conclusions: In this study, proximal segment stability was improved with a greater quantity of screws and with locked interlocking screws.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 34 条
[21]   Proximal tibial fracture stability with intramedullary nail fixation using oblique interlocking screws [J].
Laflamme, GY ;
Heimlich, D ;
Stephen, D ;
Kreder, HJ ;
Whyne, CM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (07) :496-502
[22]  
LANG GJ, 1995, CLIN ORTHOP RELAT R, P64
[23]   Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: A biomechanical study [J].
Minihane, Keith P. ;
Lee, Chris ;
Ahn, Chulhyun ;
Zhang, Li-Qun ;
Merk, Bradley R. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (08) :562-566
[24]   Locking plate technology and its role in osteoporotic fractures [J].
Miranda, Michael A. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 :35-39
[25]  
Mueller CA, 2005, J BONE JOINT SURG BR, V87B, P426, DOI 10.1302/0301-620X.87B3
[26]   Intramedullary nailing of proximal quarter tibial fractures [J].
Nork, Sean E. ;
Barei, David P. ;
Schildhauer, Thomas A. ;
Agel, Julie ;
Holt, Sarah K. ;
Schrick, Jason L. ;
Sangeorzan, Bruce J. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (08) :523-528
[27]   Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws [J].
Ricci, WM ;
O'Boyle, M ;
Borrelli, J ;
Bellabarba, C ;
Sanders, R .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (04) :264-270
[28]   Biomechanical stability of intramedullary nailed high proximal third tibial fractures with cement augmented proximal screws [J].
Roth, SE ;
Kreder, H ;
Stephen, D ;
Whyne, CM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (07) :457-461
[29]   Implant failure in tibial nailing [J].
Ruiz, AL ;
Kealey, WDC ;
MCCoy, GF .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (05) :359-362
[30]   Fracture strain and stability with additional locking screws in intramedullary nailing: A biomechanical study [J].
Sayana, Murali K. ;
Davis, Benjamin J. ;
Kajoor, Birender ;
Rahmatalla, Aziz ;
Maffulli, Nicola .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (05) :1053-1057