Inter-laboratory Variability of Current Immunoassay Methods for Tacrolimus among Japanese Hospitals

被引:18
作者
Miura, Masatomo [1 ]
Masuda, Satohiro [2 ]
Egawa, Hiroto [3 ]
Yuzawa, Kenji [4 ]
Matsubara, Kazuo [5 ]
机构
[1] Akita Univ Hosp, Dept Pharm, 1-1-1 Hondo, Akita 0108543, Japan
[2] Kyushu Univ Hosp, Dept Pharm, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
[3] Tokyo Womens Med Univ, Dept Surg, Shinjuku Ku, 8-1 Kawada Cho, Tokyo 1628666, Japan
[4] Natl Hosp Org, Mito Med Ctr, Dept Transplantat Surg, 280 Sakuranosato, Ibaraki, Ibaraki 3119193, Japan
[5] Kyoto Univ Hosp, Dept Clin Pharmacol & Therapeut, Sakyo Ku, Kyoto 6068501, Japan
关键词
tacrolimus; immunoassay; coefficient of variation; quality control; SOLID-ORGAN TRANSPLANTATION; COLUMN-MEDIATED IMMUNOASSAY; TANDEM MASS-SPECTROMETRY; ASSAY; BLOOD; LIVER; RECIPIENTS; ANALYZER; KIDNEY;
D O I
10.1248/bpb.b16-00249
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The aim of this study was to assess inter-hospital laboratory variability (coefficient of variation; CV) of immunoassay methods for tacrolimus and the comparability of control samples and results obtained by immunoassay measurements. One hundred seven hospital laboratories routinely performing therapeutic drug monitoring (TDM) of tacrolimus participated in the study. Thirteen spiked samples with known tacrolimus concentrations in the range of 0-26.0 ng/mL were prepared. Each spiked sample was analyzed according to the manufacturer's instructions using an affinity column-mediated immunoassay (ACMIA) on a Dimension analyzer, the enzyme multiplied immunoassay technique (EMIT) on a Viva-E (R) analyzer, a chemiluminescent enzyme immunoassay (CLIA) on the Architect (R) system, and the electro-chemiluminescence immunoassay (ECLIA) on a cobas (R) analyzer. The 20% coefficient of variation values for the CLIA, ACMIA, EMIT, and ECLIA assays in the hospital laboratories were 1.82, 5.36, 4.59, and 0.89 ng/mL, respectively. CLIA and ECLIA had positive biases at concentrations of tacrolimus above 12 ng/mL relative to the spiked concentration, whereas the assay bias for ACMIA tended to be more negative at concentrations of tacrolimus above 6ng/mL. EMIT had positive biases over the wide concentration range of 0.0-26.0 ng/mL (mean of mean errors 1.224). CLIA and ECLIA provided adequate precision at the target tacrolimus concentration of 3.0 ng/mL, whereas ACMIA and EMIT were unable to respond to target concentrations between 3.0 and 5.0ng/mL for renal transplant recipients. Appropriate assessment of tacrolimus concentration by an assay having higher sensitivity, precision, and accuracy is necessary to ensure long-term survival of transplant recipients receiving tacrolimus.
引用
收藏
页码:1331 / 1337
页数:7
相关论文
共 20 条
[1]   Evaluation of 2 Immunoassays for Monitoring Low Blood Levels of Tacrolimus [J].
Amann, Shawn ;
Parker, Thomas S. ;
Levine, Daniel M. .
THERAPEUTIC DRUG MONITORING, 2009, 31 (02) :273-276
[2]   Quantification of cyclosporine and tacrolimus in whole blood. Comparison of liquid chromatography-electrospray mass spectrometry with the enzyme multiplied immunoassay technique [J].
Ansermot, Nicolas ;
Fathi, Marc ;
Veuthey, Jean-Luc ;
Desmeules, Jules ;
Rudaz, Serge ;
Hochstrasser, Denis .
CLINICAL BIOCHEMISTRY, 2008, 41 (10-11) :910-913
[3]   Evaluation of the Architect® tacrolimus assay in kidney, liver, and heart transplant recipients [J].
Bazin, Christophe ;
Guinedor, Amelie ;
Barau, Caroline ;
Gozalo, Claire ;
Grimbert, Philippe ;
Duvoux, Christophe ;
Furlan, Valerie ;
Massias, Laurent ;
Hulin, Anne .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 53 (04) :997-1002
[4]   Application of the EMIT 2000 Tacrolimus assay on the Abbott Architect c8000 high volume clinical chemistry analyzer [J].
Boer, Klas ;
Deufel, Thomas ;
Schmidt, Dirk ;
Streck, Sibylle ;
Kiehntopf, Michael .
CLINICAL BIOCHEMISTRY, 2006, 39 (10) :1041-1043
[5]   Analytical performance characteristics of the Abbott Architect i2000 Tacrolimus assay; comparisons with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and Abbott IMx methods [J].
De, Barun K. ;
Jimenez, E. ;
De, S. ;
Sawyer, J. C. ;
McMillin, G. A. .
CLINICA CHIMICA ACTA, 2009, 410 (1-2) :25-30
[6]  
Gonschior AK, 1996, CLIN CHEM, V42, P1426
[7]   Assessment of Four Methodologies (Microparticle Enzyme Immunoassay, Chemiluminescent Enzyme Immunoassay, Affinity Column-Mediated Immunoassay, and Flow Injection Assay-Tandem Mass Spectrometry) for Measuring Tacrolimus Blood Concentration in Japanese Liver Transplant Recipients [J].
Hashi, S. ;
Masuda, S. ;
Kikuchi, M. ;
Uesugi, M. ;
Yano, I. ;
Omura, T. ;
Yonezawa, A. ;
Fujimoto, Y. ;
Ogawa, K. ;
Kaido, T. ;
Uemoto, S. ;
Matsubara, K. .
TRANSPLANTATION PROCEEDINGS, 2014, 46 (03) :758-760
[8]   Association between CYP3A5 Genotypes in Graft Liver and Increase in Tacrolimus Biotransformation from Steroid Treatment in Living-donor Liver Transplant Patients [J].
Hosohata, Keiko ;
Uesugi, Miwa ;
Hashi, Sachiyo ;
Hosokawa, Mio ;
Inui, Ken-ichi ;
Matsubara, Kazuo ;
Ogawa, Kohei ;
Fujimoto, Yasuhiro ;
Kaido, Toshimi ;
Uemoto, Shinji ;
Masuda, Satohiro .
DRUG METABOLISM AND PHARMACOKINETICS, 2014, 29 (01) :83-89
[9]   CONSENSUS DOCUMENT - THERAPEUTIC MONITORING OF TACROLIMUS (FK-506) [J].
JUSKO, WJ ;
THOMSON, AW ;
FUNG, J ;
MCMASTER, P ;
WONG, SH ;
ZYLBERKATZ, E ;
CHRISTIANS, U ;
WINKLER, M ;
FITZSIMONS, WE ;
LIEBERMAN, R ;
MCBRIDE, J ;
KOBAYASHI, M ;
WARTY, V ;
SOLDIN, SJ .
THERAPEUTIC DRUG MONITORING, 1995, 17 (06) :606-614
[10]   The EMIT 2000 tacrolimus assay: an application protocol for the Beckman Synchron LX20 PRO analyzer [J].
LeGatt, DF ;
Shalapay, CE ;
Cheng, SB .
CLINICAL BIOCHEMISTRY, 2004, 37 (11) :1022-1030