Influence of time resolution in the estimation of self-consumption and self-sufficiency of photovoltaic facilities

被引:16
作者
Ayala-Gilardon, A. [1 ]
Sidrach-de-Cardona, M. [1 ]
Mora-Lopez, L. [2 ]
机构
[1] Univ Malaga, Escuela Ingn Ind, Dept Fis Aplicada 2, Campus Teatinos, E-29071 Malaga, Spain
[2] Univ Malaga, ETSI Informat, Dept Lenguajes & Ciencias Computat, Campus Teatinos, E-29071 Malaga, Spain
关键词
Self-sufficiency; Self-consumption; Grid-connected photovoltaic system; Time resolution; Evaluation of a PV facility; BATTERY SYSTEMS; STATISTICAL-ANALYSIS; PV; SIMULATION; BUILDINGS;
D O I
10.1016/j.apenergy.2018.08.072
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The main objective of this paper is to analyze and evaluate the impact of time resolution when estimating self consumption and self-sufficiency in grid-connected photovoltaic facilities. The consumption data were obtained from a photovoltaic facility installed in Malaga (Spain). They were extrapolated to analyze other PV facility sizes for the same location. The size of the PV installation that generates an annual energy equal to the annual consumption has been estimated. This size has been used as benchmark size in order to generalize the results. The different time resolutions analyzed to estimate self-sufficiency and self-consumption parameters range from 10 s to one year. These different time aggregation levels are related to the different net-metering regulations. The results show that using hourly data overestimates these parameters compared to the results at smaller time resolutions; when hourly data are used instead of 10 s data, the differences between these parameters are around 9%. This may be due to the fact that this, and higher, time resolution does not take steady state voltages and power flows into account. Thus, increasing the time resolution can cause relevant information loss. Moreover, the results are also useful for analyzing different net metering systems by means of the self-consumption and self-sufficiency metrics. Self-consumption and self-sufficiency for the facility benchmark size range from 48% to 98% depending on the time resolution.
引用
收藏
页码:990 / 997
页数:8
相关论文
共 36 条
  • [1] Abdulla K., 2017, IEEE POW ENER SOC GE, P1, DOI 10.1109/PESGM.2017.8274019.
  • [2] Energy self-sufficiency, grid demand variability and consumer costs: Integrating solar PV, Stirling engine CHP and battery storage
    Balcombe, Paul
    Rigby, Dan
    Azapagic, Adisa
    [J]. APPLIED ENERGY, 2015, 155 : 393 - 408
  • [3] Data acquisition system for photovoltaic systems performance monitoring
    Benghanem, M
    Maafi, A
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (01) : 30 - 33
  • [4] Benitez Javier, 2014, TECHNICAL REPORT
  • [5] Bucher C., 2013, PowerTech (POWERTECH), P1
  • [6] Monitoring, modelling and simulation of PV systems using LabVIEW
    Chouder, Aissa
    Silvestre, Santiago
    Taghezouit, Bilal
    Karatepe, Engin
    [J]. SOLAR ENERGY, 2013, 91 : 337 - 349
  • [7] Chowdhury S.P., 2008, POWER ENERGY SOC GEN, P1, DOI DOI 10.1109/PES.2008.4596787
  • [8] A Demand Response Energy Management Scheme for Industrial Facilities in Smart Grid
    Ding, Yue Min
    Hong, Seung Ho
    Li, Xiao Hui
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2014, 10 (04) : 2257 - 2269
  • [9] Figueiredo Joao M., 2008, 2008 5th International Conference on the European Electricity Market (EEM 2008), P1, DOI 10.1109/EEM.2008.4579001
  • [10] Opportunities and Challenges of Wireless Sensor Networks in Smart Grid
    Gungor, Vehbi C.
    Lu, Bin
    Hancke, Gerhard P.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (10) : 3557 - 3564