Life Cycle Assessment of Dispersed Phase Change Material Heat Accumulators for Cooperation with Buildings in the District Heating System

被引:8
作者
Turski, Michal [1 ]
Jachura, Agnieszka [1 ]
机构
[1] Czestochowa Tech Univ, Fac Infrastruct & Environm, 73 J H Dabrowskiego St, PL-42200 Czestochowa, Poland
关键词
district heating system; hybrid substations; PCM; district heating storage; life cycle assessment; THERMAL-ENERGY STORAGE; SAVINGS; DEMAND; WATER; PCM;
D O I
10.3390/en15165771
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The wide use of energy-efficient district heating systems allows for decreased atmospheric pollution resulting from lower emissions. One of the ways to increase the efficiency of existing district heating systems, and a key element of new systems using renewable energy sources, is modern heat storage technology-the utilization of dispersed PCM heat accumulators. However, the use of different solutions and the inconsistency of selection methods make it difficult to compare the obtained results. Therefore, in this paper, using TRNSYS software, a standardization of the selection of dispersed PCM heat accumulators for cooperation with buildings in the DHS was proposed along with a Life Cycle Assessment. Life Cycle Assessment could be a good, versatile indicator for new developments in district heating systems. A new contribution to the research topic was the Life Cycle Assessment itself as well as the range of heat output of the substations up to 2000 kW and the development of nomograms and unitary values for the selection of individual parameters based on the relative amount of heat uncollected by buildings. The technical potential of heat storage value, %Delta Q(i)(,st), was from 49.4% to 59.6% of the theoretical potential of heat storage. The increases in the active volume of the PCM heat accumulator, dV(PCM), and the mass of the required amount of PCM, dm(st), were, respectively, 0.8 x 10(-2)-4.0 m(3)/kW and 1.3-6.7 x 10(-2) kg/kW. Due to dispersed heat storage, an increase in system efficiency of 41% was achieved. LCA analysis showed that a positive impact on the environment was achieved, expressed as negative values of the Eco-indicator from -0.504 x 10(-2) to -6.44 x 10(-2) kPt/kW.
引用
收藏
页数:24
相关论文
共 45 条
[1]   SHORT-TERM THERMAL-ENERGY STORAGE [J].
ABHAT, A .
REVUE DE PHYSIQUE APPLIQUEE, 1980, 15 (03) :477-501
[2]   LOW-TEMPERATURE LATENT-HEAT THERMAL-ENERGY STORAGE - HEAT-STORAGE MATERIALS [J].
ABHAT, A .
SOLAR ENERGY, 1983, 30 (04) :313-332
[3]  
[Anonymous], 2018, ENERGY EFFICIENCY AC
[4]  
[Anonymous], 2009, 14040 PNEN
[5]  
[Anonymous], 2009, PN-EN ISO 14044
[6]  
[Anonymous], 2016, SimaPro Database - Manual Methods Library. Amersfoort
[7]  
Basakayi J.K., 2014, INT J ADV ENG TECHNO, V7, P692
[8]   A comparative study of district and individual energy systems providing electrical-based heating, cooling, and domestic hot water to a low-energy use residential community [J].
Brum, Magdalena ;
Erickson, Paul ;
Jenkins, Bryan ;
Kornbluth, Kurt .
ENERGY AND BUILDINGS, 2015, 92 :306-312
[9]  
Bruno F., 2015, Advances in Thermal Energy Storage Systems, P201, DOI DOI 10.1533/9781782420965.2.201
[10]  
Castell A., 2014, ADV THERMAL ENERGY S, P285, DOI DOI 10.1533/9781782420965.2.285