Delayed left atrial appendage contrast filling in computed tomograms after percutaneous left atrial appendage occlusion

被引:10
作者
Lim, Yeong-Min [1 ]
Kim, Jung-Sun [1 ]
Kim, Tae-Hoon [1 ]
Uhm, Jae-Sun [1 ]
Shim, Chi Young [1 ]
Joung, Boyoung [1 ]
Hong, Geu-Ru [1 ]
Lee, Moon-Hyoung [1 ]
Jang, Yang-Soo [1 ]
Pak, Hui-Nam [1 ]
机构
[1] Yonsei Univ Hlth Syst, Seoul, South Korea
关键词
Left atrial appendage; Contrast-filling; Computed tomogram; Stroke; AMPLATZER CARDIAC PLUG; STROKE PREVENTION; CLOSURE DEVICE; FIBRILLATION; WARFARIN; WATCHMAN; IMPACT; CT; RECURRENCE; THERAPY;
D O I
10.1016/j.jjcc.2017.04.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The gold standard for the follow-up of left atrial appendage occlusion (LAAO) is performing transesophageal echocardiogram (TEE) at 45 days after LAAO; however, the duration for complete LAA seal-off after percutaneous LAAO is unknown in humans. We retrospectively evaluated the LAA contrast filling (CF) rate in follow-up cardiac computed tomography (CT) scans after LAAO. Methods: We included 35 patients (age 67.5 +/- 10.9 years, CHA(2)DS(2)VASc 4.2 +/- 1.6, HAS-BLED 3.7 +/- 1.5) who underwent LAAO [16 WATCHMAN, 19 Amplatzer cardiac plug (ACP)] and follow-up cardiac CT within 6 months after LAAO, and evaluated the LAA-CF rates. Eighteen patients (51.4%) underwent multiple episodes of CT follow-up. Results: 1. The proportions of patients with LAA-CF were 54.2% (19/35) at 6 months, 55.5% (5/9) at 6-18 months, and 33.3% (3/9) at > 18 months after LAAO. 2. Among 23 patients with no peridevice leak at the 2 months TEE, LAA-CFs were found in 12 patients at 2.8 +/- 1.5 months (66.6% in WATCHMAN and 36.3% in ACP; p = 0.158). 3. Among eight patients with consecutive follow-up CT (>= 3 times), LAA-CFs were partially reduced in three; however, there was no complete LAA seal-off at 19.0 +/- 11.3 months. 4. A larger LAA landing zone diameter was independently associated with LAA-CF in follow-up CT [OR 1.45 (1.08-1.96), p = 0.013, adjusted for age, sex, and device type]. Conclusions: Delayed LAA-CF is common after LAAO, with considerable discrepancies between cardiac CT and TEE findings. Although the clinical significance of LAA-CF is unclear, 45 days seem to be insufficient for complete LAA seal-off after LAAO. (C) 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:571 / 577
页数:7
相关论文
共 27 条
[1]   Intraprocedural and Long-Term Incomplete Occlusion of the Left Atrial Appendage Following Placement of the WATCHMAN Device: A Single Center Experience [J].
Bai, Rong ;
Horton, Rodney P. ;
Di Biase, Luigi ;
Mohanty, Prasant ;
Pump, Agnes ;
Cardinal, Deb ;
Scallon, Chantel ;
Mohanty, Sanghamitra ;
Santangeli, Pasquale ;
Brantes, Mauricio C. ;
Sanchez, Javier ;
Burkhardt, J. David ;
Zagrodzky, Jason D. ;
Gallinghouse, G. Joseph ;
Natale, Andrea .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (05) :455-461
[2]   LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography [J].
Behnes, Michael ;
Akin, Ibrahim ;
Sartorius, Benjamin ;
Fastner, Christian ;
El-Battrawy, Ibrahim ;
Borggrefe, Martin ;
Haubenreisser, Holger ;
Meyer, Mathias ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
BMC MEDICAL IMAGING, 2016, 16
[3]   Left Atrial Appendage Occlusion Device and Novel Oral Anticoagulants Versus Warfarin for Stroke Prevention in Nonvalvular Atrial Fibrillation Systematic Review and Meta-Analysis of Randomized Controlled Trials [J].
Briceno, David F. ;
Villablanca, Pedro ;
Cyrille, Nicole ;
Massera, Daniele ;
Bader, Eric ;
Manheimer, Eric ;
Aagaard, Philip ;
Ferrick, Kevin ;
Gross, Jay ;
Kim, Soo Gyum ;
Krumerman, Andrew ;
Palma, Eugen ;
Guttenplan, Nils ;
Romero, Jorge ;
Fisher, John ;
Garcia, Mario ;
Natale, Andrea ;
Di Biase, Luigi .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (05) :1057-1064
[4]   Analysis of in vivo left atrial appendage morphology in patients with atrial fibrillation: a direct comparison of transesophageal echocardiography, planar cardiac CT, and segmented three-dimensional cardiac CT [J].
Budge, Loren P. ;
Shaffer, Katherine M. ;
Moorman, J. Randall ;
Lake, Douglas E. ;
Ferguson, John D. ;
Mangrum, J. Michael .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 23 (02) :87-93
[5]   Multimodality imaging in preoperative assessment of left atrial appendage transcatheter occlusion with the Amplatzer Cardiac Plug [J].
Clemente, Alberto ;
Avogliero, Francesco ;
Berti, Sergio ;
Paradossi, Umberto ;
Jamagidze, Giuli ;
Rezzaghi, Marco ;
Della Latta, Daniele ;
Chiappino, Dante .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (11) :1276-1287
[6]   Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation: an update [J].
De Backer, O. ;
Arnous, S. ;
Ihlemann, N. ;
Vejlstrup, N. ;
Jorgensen, E. ;
Pehrson, S. ;
Krieger, T. D. W. ;
Meier, P. ;
Sondergaard, L. ;
Franzen, O. W. .
OPEN HEART, 2014, 1 (01)
[7]   Left atrial appendage closure with the Amplatzer™ Cardiac Plug: Impact of shape and device sizing on follow-up leaks [J].
Freixa, Xavier ;
Tzikas, Apostolos ;
Sobrino, Ayax ;
Chan, Jason ;
Basmadjian, Arsene J. ;
Ibrahim, Reda .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) :1023-1027
[8]   Left Atrial Appendage Closure as an Alternative to Warfarin for Stroke Prevention in Atrial Fibrillation A Patient-Level Meta-Analysis [J].
Holmes, David R., Jr. ;
Doshi, Shephal K. ;
Kar, Saibal ;
Price, Matthew J. ;
Sanchez, Jose M. ;
Sievert, Horst ;
Valderrabano, Miguel ;
Reddy, Vivek Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (24) :2614-2623
[9]   Prospective Randomized Evaluation of the Watchman Left Atrial Appendage Closure Device in Patients With Atrial Fibrillation Versus Long-Term Warfarin Therapy [J].
Holmes, David R., Jr. ;
Kar, Saibal ;
Price, Matthew J. ;
Whisenant, Brian ;
Sievert, Horst ;
Doshi, Shephal K. ;
Huber, Kenneth ;
Reddy, Vivek Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (01) :1-12
[10]   Cardiac CT and Echocardiographic Evaluation of Peri-Device Flow After Percutaneous Left Atrial Appendage Closure Using the AMPLATZER Cardiac Plug Device [J].
Jaguszewski, Milosz ;
Manes, Costantina ;
Puippe, Gilbert ;
Salzberg, Sacha ;
Mueller, Maja ;
Falk, Volkmar ;
Luescher, Thomas ;
Luft, Andreas ;
Alkadhi, Hatem ;
Landmesser, Ulf .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (02) :306-312