Numerical investigation of the flow behavior of an isothermal corner impinging jet for building ventilation

被引:13
|
作者
Ameen, Arman [1 ]
Cehlin, Mathias [1 ]
Larsson, Ulf [1 ]
Yamasawa, Haruna [2 ]
Kobayashi, Tomohiro [3 ]
机构
[1] Univ Gavle, SE-80176 Gavle, Sweden
[2] Kyushu Univ, 6-1 Kasuga Koen, Kasuga, Fukuoka 8168580, Japan
[3] Osaka Univ, 2-1 Yamadaoka, Suita, Osaka 5650871, Japan
关键词
Impinging jet ventilation; CFD analysis; Parametric study; Regression analysis; INDOOR AIR-QUALITY; MIXING VENTILATION; ENERGY-CONSUMPTION; THERMAL COMFORT; PERFORMANCE; ROOM; ACCURACY; SYSTEMS; OFFICE;
D O I
10.1016/j.buildenv.2022.109486
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The corner impinging jet concept has been proposed as a new air distribution system for use in office environments. The present paper reports the mean flow field behavior of an isothermal corner-based turbulent impinging jet in a room. A detailed experimental study is carried out to validate the numerical simulations, and the predictions are performed using three turbulence models. RNG k - epsilon model was chosen for this study. This study investigates the influence different configuration parameters such as jet discharge height, diffuser geometry (shape and size) and supply airflow rate have on the flow field. The results show that the diffuser geometries used in this study had in general a minor effect on the velocity developments along the centerline of the floor, maximum velocity decay and jet spreading rate except for some specific cases. When evaluating the triangle geometry cases, the results show that all the cases with volume flow <20 L/s are able to meet Boverket's building regulations velocity requirement both for summer and winter. The applicability evaluation show that the results can be considered for room sizes between approximate to 25 and 100 m(2). In addition, the wall confinement effect (90 degrees vs. 180 degrees) is having a significant impact on the maximum velocity decay for corner impinging jet ventilation. In the regression analysis the results shows that the distance along the diagonal centerline of the room has the most impact on the evaluation of maximum velocity decay and jet spreading rate.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Numerical Evaluation of the Flow Field of an Isothermal Dual-Corner Impinging Jet for Building Ventilation
    Ameen, Arman
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    BUILDINGS, 2022, 12 (10)
  • [2] Numerical investigation of the flow behavior of an isothermal impinging jet in a room
    Chen, H. J.
    Moshfegh, B.
    Cehlin, M.
    BUILDING AND ENVIRONMENT, 2012, 49 : 154 - 166
  • [3] Experimental investigation of the flow behavior of an isothermal impinging jet in a closed cabin
    Yao, Shiyong
    Guo, Yong
    Jiang, Nan
    Liu, Junjie
    BUILDING AND ENVIRONMENT, 2015, 84 : 238 - 250
  • [4] Numerical investigation of indoor thermal comfort and air quality for an office equipped with corner impinging jet ventilation
    Ameen, Arman
    Cehlin, Mathias
    Karimipanah, Taghi
    ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (05) : 578 - 604
  • [5] Numerical investigation of the flow and heat behaviours of an impinging jet
    Wang, Peng
    Lv, Jizu
    Bai, Minli
    Wang, Yuyan
    Hu, Chengzhi
    INTERNATIONAL JOURNAL OF COMPUTATIONAL FLUID DYNAMICS, 2014, 28 (6-10) : 301 - 315
  • [6] Investigation on the flow and thermal behavior of impinging jet ventilation systems in an office with different heat loads
    Chen, H. J.
    Moshfegh, B.
    Cehlin, M.
    BUILDING AND ENVIRONMENT, 2013, 59 : 127 - 144
  • [7] Numerical investigation of impinging jet ventilation in ICUs: Is thermal stratification a problem?
    Wang, Lei
    Wang, Zhiqiang
    Zhu, Sirui
    Zhu, Zhe
    Jin, Tao
    Wei, Jianjian
    BUILDING SIMULATION, 2023, 16 (07) : 1173 - 1185
  • [8] Numerical investigation of impinging jet ventilation in ICUs: Is thermal stratification a problem?
    Lei Wang
    Zhiqiang Wang
    Sirui Zhu
    Zhe Zhu
    Tao Jin
    Jianjian Wei
    Building Simulation, 2023, 16 : 1173 - 1185
  • [9] Numerical simulation of flow and thermal oscillations in a non-isothermal laminar impinging jet
    Department of Mechanical Engineering, Srinivasa Institute of Engineering and Technology, Chennai-56, India
    不详
    Int. J. Heat Technol., 2007, 2 (65-73):
  • [10] Numerical investigation of the thermal and ventilation performance of a combined impinging jet ventilation and passive chilled beam system
    Hu, Jun
    Kang, Yanming
    Lu, Yihang
    Yu, Jia
    Li, He
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2022, 226