A generalized model for the conversion from CT numbers to linear attenuation coefficients

被引:92
作者
Bai, CY [1 ]
Shao, L [1 ]
Da Silva, AJ [1 ]
Zhao, Z [1 ]
机构
[1] Philips Med Syst, Milpitas, CA 95035 USA
关键词
conversion factor; CT number; CT/PET imaging; CT/SPECT imaging; linear attenuation coefficient; piecewise linear conversion; water-A assumption;
D O I
10.1109/TNS.2003.817281
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a generalized model for accurate conversion from CT numbers to linear attenuation coefficients (LACs) by introducing a material-dependent conversion factor (CF). Using this model and assuming that a material x is a uniform mixture of water and another material A (denoted as "water-A assumption" in this paper), we show that the conversion from CT number of x (HUx) to LAC is linear. The slope of the linear function is determined by the attenuation property of material A. This generalized model can be applied to the conversion from CT images to attenuation maps for combined CT/PET and CT/SPECT imaging. When HUx is less than zero, we use "water-air assumption," otherwise, we us "water-cortical-bone assumption." This leads to different slopes for the linear conversion for CT numbers below and above zero. In practice, for each CT system, a cylindrical phantom with a small cortical bone cylinder in the center is filled with water and scanned once for each operational kVp. The CT number of the cortical bone (HUCB) at each kVp is then measured and used for the conversion. Experiments show that the conversion using this technique is accurate. In addition, the proposed technique can be used to characterize CT systems by obtaining the effective CT energy at each kVp. This allows for absolute attenuation measurement using CT systems instead of the relative measurement given by CT-numbers.
引用
收藏
页码:1510 / 1515
页数:6
相关论文
共 13 条
  • [1] ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY
    ALVAREZ, RE
    MACOVSKI, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) : 733 - 744
  • [2] Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: Myocardial perfusion assessment
    Blankespoor, SC
    Wu, X
    Kalki, K
    Brown, JK
    Tang, HR
    Cann, CE
    Hasegawa, BH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) : 2263 - 2274
  • [3] Burger C, 2001, J NUCL MED, V42, p57P
  • [5] An iterative maximum-likelihood polychromatic algorithm for CT
    De Man, B
    Nuyts, J
    Dupont, P
    Marchal, G
    Suetens, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (10) : 999 - 1008
  • [6] A PROTON PROFILE MONITOR USING AN AMORPHOUS-SILICON PHOTODIODE-ARRAY
    HASEGAWA, K
    SUGIURA, H
    MOCHIKI, K
    TAKAHASHI, H
    HAYAKAWA, Y
    INADA, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 569 - 572
  • [7] Attenuation correction for a combined 3D PET/CT scanner
    Kinahan, PE
    Townsend, DW
    Beyer, T
    Sashin, D
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 2046 - 2053
  • [8] LACROIX KJ, 1994, IEEE T NUCL SCI, V41, P2799
  • [9] GENERALIZED IMAGE COMBINATIONS IN DUAL KVP DIGITAL RADIOGRAPHY
    LEHMANN, LA
    ALVAREZ, RE
    MACOVSKI, A
    BRODY, WR
    PELC, NJ
    RIEDERER, SJ
    HALL, AL
    [J]. MEDICAL PHYSICS, 1981, 8 (05) : 659 - 667
  • [10] A FRAMEWORK FOR SPECTRAL ARTIFACT CORRECTIONS IN X-RAY CT
    STONESTROM, JP
    ALVAREZ, RE
    MACOVSKI, A
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (02) : 128 - 141