Biomechanical analysis of dual versus lateral locked plating in elderly bicondylar tibial plateau fractures: Does medial comminution matter?

被引:2
作者
Velez, Dencel A. Garcia [1 ]
Headford, Mikel [1 ]
Suresh, Krishna Vangipuram [1 ]
Liberatos, Paraskevi Marousa [1 ]
Bledsoe, Gary [2 ]
Revak, Thomas [1 ]
机构
[1] St Louis Univ Hosp, St Louis, MO 63104 USA
[2] Dept Biomech Engn, St Louis, MO USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2022年 / 53卷 / 10期
关键词
Bicondylar tibial plateau fracture; Elderly; Osteoporosis; Dual versus lateral plating; Biomechanics; Medial comminution; LESS INVASIVE STABILIZATION; INTERNAL-FIXATION; OPEN REDUCTION; POSTEROMEDIAL FRAGMENT; OPERATIVE TREATMENT; PATIENTS OLDER; LOCKING PLATE; OUTCOMES; SINGLE; COMPLICATIONS;
D O I
10.1016/j.injury.2022.08.039
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To assess dual plating versus lateral locked plate fixation of bicondylar tibial plateau fractures in an elderly cadaveric model with and without medial bone loss Participants: 10 pairs of elderly (range 78-93 years of age) fresh frozen tibias. Intervention: Bicondylar tibial plateau fractures were created reproducing AO/OTA 41 C1 (without medial bone loss) and C2 fractures (with medial bone loss). Cadavers were randomized to 4 different groups. Groups 1 and 2 were 41 C1 fractures and fixated with either dual or lateral plating, respectively. Groups 3 and 4 were fixated in a similar fashion with medial metaphyseal bone loss (41 C2 fracture) with dual plating Group 3 and lateral plating group 4. Lateral plating consisted of a 3.5 mm 5-hole lateral plate (ALPS, ZimmerBiomet) with 6 bicortical locking screws proximally and two diaphyseal screws. Dual plat-ing groups underwent lateral plating and additional 3.5 mm 5-hole posteromedial 1/3 tubular plate (Zim-merBiomet) placed at the apex of the fracture with two shaft screws and one unicortical screw proxi-mally. Specimens were tested in a Mechanical Testing System (MTS) machine loading both condyles. Outcome measurements: Specimens were loaded to 300 N and coronal alignment obtained. Specimens were then cycled from 100 N to 700 N for 5000 cycles at 2 Hz. Average axial displacement, maximal displacement, average force and coronal alignment after 50 0 0 cycles were recorded. Lastly, force to failure was recorded at 100 N/sec. Results: Mean axial displacement was 4.21 mm ranging from 3.12 mm in group 1 to 5.92 mm in group 4 ( P = 0.51). Failure force averaged 3340 N ranging from 4342 N in group 1 to 2433 N in group 4 ( P = 0.36). Maximal displacement ranged from 3.69 mm in group 1 to 7.37 mm in group 4 ( P = 0.21). Change in coronal alignment ranged from 0.98 degrees in group 1 to 1.97 degrees in group 4 ( P = 0.45). No statistically significant difference was noted between all four groups for all data points. Conclusion: The results of this study demonstrate that a lateral locked plate may offer an alternative means of fixation in AO/OTA 41 C1 and C2 fractures. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3109 / 3114
页数:6
相关论文
共 43 条
[1]   Treatment of displaced bicondylar tibial plateau fractures (OTA-41C2&3) in patients older than 60 years of age [J].
Ali, AM ;
Burton, T ;
Hashmi, T ;
Saleh, T .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (05) :346-352
[2]   Failure of fixation of tibial plateau fractures [J].
Ali, AM ;
El-Shafie, M ;
Willett, KM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) :323-329
[3]   Frequency and fracture morphology of the posteromedial fragment in bicondylar tibial plateau fracture patterns [J].
Barei, David P. ;
O'Mara, Timothy J. ;
Taitsman, Lisa A. ;
Dunbar, Robert P. ;
Nork, Sean E. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (03) :176-182
[4]   Functional outcomes of severe bicondylar plateau fractures treated with dual incisions and medial and lateral plates [J].
Barei, David P. ;
Nork, Sean E. ;
Mills, William J. ;
Coles, Chad P. ;
Henley, M. Bradford ;
Benirschke, Stephen K. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (08) :1713-1721
[5]   Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique [J].
Barei, DP ;
Nork, SE ;
Mills, WJ ;
Henley, MB ;
Benirschke, SK .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (10) :649-657
[6]   THE RESULTS OF SURGICAL-MANAGEMENT OF DISPLACED TIBIAL PLATEAU FRACTURES IN THE ELDERLY [J].
BIYANI, A ;
REDDY, NS ;
CHAUDHURY, J ;
SIMISON, AJM ;
KLENERMAN, L .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (05) :291-297
[7]  
Chang HR, 2016, INT ORTHOP, V40, P2129, DOI 10.1007/s00264-016-3157-8
[8]   Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: A cadaveric model [J].
Dougherty, Paul J. ;
Kim, Do-Gyoon ;
Meisterling, Steve ;
Wybo, Christopher ;
Yeni, Yener .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (06) :399-403
[9]   Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: Clinical experience and a laboratory comparison with double plating [J].
Egol, KA ;
Su, E ;
Tejwani, NC ;
Sims, SH ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 57 (02) :340-346
[10]   Staged management of high-energy proximal tibia fractures (OTA types 41) - The results of a prospective, standardized protocol [J].
Egol, KA ;
Tejwani, NC ;
Capla, EL ;
Wolinsky, PL ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (07) :448-455