OPTIMAL ULTRASOUND CRITERIA FOR DEFINING THE SEVERITY OF VERTEBRAL ARTERY IN-STENT RESTENOSIS

被引:17
|
作者
Jia, Lingyun [1 ]
Hua, Yang [1 ]
Li, Jingzhi [1 ]
Duan, Chun [1 ]
Zhou, Yinghua [1 ]
Jiao, Liqun [2 ]
机构
[1] Capital Med Univ, Xuanwu Hosp, Dept Vasc Ultrasonog, Beijing, Peoples R China
[2] Capital Med Univ, Xuanwu Hosp, Dept Neurosurg, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Vertebral artery; Stenting; In-stent restenosis; Color Doppler ultrasonography; Diagnostic criteria; CAROTID-ARTERY; VELOCITY CRITERIA; DUPLEX ULTRASONOGRAPHY; STENOSIS; ANGIOPLASTY;
D O I
10.1016/j.ultrasmedbio.2014.10.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of the study described here was to establish ultrasound criteria for defining the severity of vertebral artery in-stent restenosis. A total of 197 patients with vertebral artery stents were enrolled in this study. Color Doppler ultrasonography was performed after stenting. Peak systolic velocity and end-diastolic velocity within the stent (PSVstent, EDVstent) and at the intervertebral segments were recorded. The ratio of the PSV at the origin to that at the intervertebral segment was calculated. With digital subtraction angiography as the reference standard, the optimal cutoff values of hemodynamic parameters identifying 50%-69% and 70%-99% restenosis were determined by receiver operating characteristic analysis. The optimal cutoff values of hemodynamic parameters identifying 50%-69% restenosis were PSVstent >= 170 cm/s, EDVstent >= 45 cm/s and PSV ratio >= 2.7, and those for 70%-99% restenosis were PSVstent >= 220 cm/s, EDVstent >= 55 cm/s and PSV ratio >= 4.2. In conclusion, color Doppler ultrasonography is a reliable method for monitoring patients with avertebral artery stents. (E-mail: dryanghua99@163.com) (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:775 / 780
页数:6
相关论文
共 50 条
  • [41] Evaluation of In-Stent Restenosis After Stent Implantation in the Vertebral Artery Ostium by Multislice Computed Tomography Angiography: Factors Affecting Accurate Diagnosis
    Y. J. Lee
    Y. S. Lim
    H. W. Lim
    I. K. Yu
    Y. J. Kim
    W. J. Yoo
    Clinical Neuroradiology, 2015, 25 : 379 - 386
  • [42] Coronary artery stent fracture with aneurysm formation and in-stent restenosis
    Manola, Sime
    Pintaric, Hrvoje
    Pavlovic, Nikola
    Stambuk, Kresimir
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 (02) : E36 - E39
  • [43] Relationship between serum endothelin-1 and in-stent restenosis following vertebral artery stenting
    Fang He
    Changyang Zhong
    Chunli Wu
    Yuan Liu
    Shufeng Yu
    Neurological Sciences, 2024, 45 : 2711 - 2717
  • [44] Restenosis after stent placement for ostial stenosis of vertebral artery
    Kogure, S
    Sakai, N
    Iihara, K
    Sakai, H
    Higashi, HST
    Takahashi, JC
    Ohta, H
    Nagamine, T
    Anei, R
    Soeda, A
    Taniguchi, A
    Nagata, I
    INTERVENTIONAL NEURORADIOLOGY, 2001, 7 : 167 - 169
  • [45] Relationship between serum endothelin-1 and in-stent restenosis following vertebral artery stenting
    He, Fang
    Zhong, Changyang
    Wu, Chunli
    Liu, Yuan
    Yu, Shufeng
    NEUROLOGICAL SCIENCES, 2024, 45 (06) : 2711 - 2717
  • [46] Cerebral collateral circulation as an independent predictor for in-stent restenosis after carotid artery stenting
    Liu, Luji
    Su, Xudong
    Zhang, Lihong
    Li, Zhongzhong
    Bu, Kailin
    Yuan, Si
    Wang, Qisong
    Wang, Ye
    Aime, Ndoumou Justin
    Liu, Zengpin
    Zhou, Cunhe
    Yu, Jianghua
    Tan, Guojun
    Guo, Li
    Liu, Xiaoyun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (05) : 2941 - 2952
  • [47] The challenge of in-stent restenosis: insights from intravascular ultrasound
    Spanos, V
    Stankovic, G
    Tobis, J
    Colombo, A
    EUROPEAN HEART JOURNAL, 2003, 24 (02) : 138 - 150
  • [48] Diagnostic accuracy of 64-slice multidetector CT angiography for detection of in-stent restenosis of vertebral artery ostium stents: comparison with conventional angiography
    Lee, Youn Joo
    Lim, Yeon Soo
    Lim, Hyun Wook
    Yoo, Won Jong
    Choi, Byung Gil
    Kim, Bum Soo
    ACTA RADIOLOGICA, 2014, 55 (08) : 1000 - 1007
  • [49] Endovascular treatment of in-stent restenosis after carotid artery stenting:: Immediate and midterm results
    Reimers, Bernhard
    Tuebler, Thilo
    De Donato, Giammarco
    Della Barbera, Mila
    Cernetti, Carlo
    Schlueter, Michael
    Mistrorigo, Flavio
    Sacca, Salvatore
    Favero, Luca
    Setacci, Francesco
    Setacci, Carlo
    Thiene, Gaetano
    Schofer, Joachim
    Angelini, Annalisa
    JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (04) : 429 - 435
  • [50] Recurrent in-stent thrombosis following V4 segment of vertebral artery stenting: A case report
    Zhang, Huijun
    Yan, Qian Feng
    Shen, Hua
    Jin, Wei
    Zhang, Zhichen
    Miao, Zhongrong
    Zhang, Yun
    Sun, Xuan
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2021, 85