Analysis of tooth movement in extraction cases using three-dimensional reverse engineering technology

被引:74
作者
Cha, Bong Kuen
Lee, Jae Yong
Jost-Brinkmann, Paul-Georg
Yoshida, Noriaki
机构
[1] Kangnung Natl Univ, Coll Dent, Dept Orthodont, Gangneung City 210702, Gangwon Prov, South Korea
[2] Charite Univ Med Berlin, Ctr Dent & Craniofacial Sci, Dept Orthodont & Dentofacial Orthoped, Berlin, Germany
[3] Nagasaki Natl Univ, Coll Dent, Dept Orthodont, Nagasaki, Japan
关键词
PALATAL RUGAE; DENTAL CASTS; CLASS-II; SURGERY; SYSTEM; FACE; POSITION; SKULL;
D O I
10.1093/ejo/cjm019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Despite inherent errors, cephalometric superimpositions are currently the most widely used means for assessing sagittal and vertical tooth movements. The purpose of this study was to compare three-dimensional (3D) digital model superimposition with cephalometric superimposition. The material was collected from initial and final maxillary casts and lateral cephalometric radiographs of 30 patients (6 males, 24 females, mean age 17.7 years) who underwent orthodontic treatment with extraction of permanent teeth. Each pair of cephalograms was traced and superimposed according to Ricketts' four-step method. 3D scanning of the maxillary dental casts was performed using INUS dental scanning solution (R), which consists of a 3D scanner, an autoscan system, and 3D reverse modelling software. The 3D superimposition was carried out using the surface-to-surface matching (best-fit method) function of the autoscan system. The antero-posterior movement of the maxillary first molar and central incisor was evaluated cephalometrically and on 3D digital models. To determine whether any difference existed between the two measuring techniques, paired t-tests and correlation analysis were undertaken. The results revealed no statistical differences between the mean incisor and molar movements as assessed cephalometrically or by 3D model superimposition. These findings suggest that the 3D digital orthodontic model superimposition technique used in this study is clinically as reliable as cephalometric superimposition for assessing orthodontic tooth movements.
引用
收藏
页码:325 / 331
页数:7
相关论文
共 34 条
  • [1] ALMEIDA MA, 1995, ANGLE ORTHOD, V65, P43
  • [2] 3 DIMENSIONAL DIGITIZATION OF THE FACE AND SKULL
    ARRIDGE, S
    MOSS, JP
    LINNEY, AD
    JAMES, DR
    [J]. JOURNAL OF MAXILLOFACIAL SURGERY, 1985, 13 (03): : 136 - 143
  • [3] A 3-dimensional analysis of molar movement during headgear treatment
    Ashmore, JL
    Kurland, BF
    King, GJ
    Wheeler, TT
    Ghafari, J
    Ramsay, DS
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 121 (01) : 18 - 29
  • [4] A vision-based three-dimensional capture system for maxillofacial assessment and surgical planning
    Ayoub, AF
    Siebert, P
    Moos, KF
    Wray, D
    Urquhart, C
    Niblett, TB
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1998, 36 (05) : 353 - 357
  • [5] CHA BK, 2002, J KOREAN DENTAL ASS, V40, P107
  • [6] Construction and testing of a computer-based intraoral laser scanner for determining tooth positions
    Commer, P
    Bourauel, C
    Maier, K
    Jäger, A
    [J]. MEDICAL ENGINEERING & PHYSICS, 2000, 22 (09) : 625 - 635
  • [7] Dahlberg G., 1940, STAT METHOD MEDICAL
  • [8] Vollbogentechnik mit dem “bending art system”Continuous arch wire technique using the bending art system
    H. Fischer-Brandies
    W. Orthuber
    J. Laibe
    E. Menzel
    [J]. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 1997, 58 (4): : 198 - 205
  • [9] FRIEL S, 1949, Dent Rec (London), V69, P74
  • [10] Ghafari J, 1998, Clin Orthod Res, V1, P102