Development of a multiplex nested consensus PCR for detection and identification of major human herpesviruses in CNS infections

被引:37
作者
Tafreshi, NK
Sadeghizadeh, M
Amini-Bavil-Olyaee, S
Ahadi, AM
Jahanzad, I
Roostaee, MH
机构
[1] Tarbiat Modares Univ, Dept Genet, Fac Bas Sci, Tehran, Iran
[2] Pasteur Inst Iran, Dept Biotechnol, Tehran, Iran
[3] Pouya Zistech Ltd, Tehran, Iran
[4] Tarbiat Modares Univ, Dept Virol, Fac Med Sci, Tehran, Iran
关键词
human herpesviruses; CNS infection; multiplex nested consensus-PCR assay (MNC-PCR);
D O I
10.1016/j.jcv.2004.05.018
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Rapid, sensitive and economical detection and identification of human herpesviruses as causative agents of central nervous system (CNS) infections are of clinical importance. The traditional methods for the detection of herpesviruses in CNS infections all suffer from limitations. PCR has a potential to overcome each of them. Objectives: The aims of this study were reducing the number of primers in multiplex PCR and increasing the sensitivity of the assay by nested PCR. Study design: A multiplex nested consensus PCR (MNC-PCR) was developed for the simultaneous detection of major human herpesviruses. A pair of conserved primers was designed for detection of HSV-1, HSV-2, CMV and EBV and another pair of conserved primers for nested PCR. For VZV, a different pair of primers was designed and another pair of primers for nested PCR. A reduction in the number of designed primer pairs (from five pairs to two in both stages of PCR) is an advantage in this assay. One hundred forty-seven cerebral spinal fluid (CSF) samples from patients that showed clinical manifestation of CNS infections were tested. Results of MNC-PCR in CSF samples were compared with those of single PCR assay for each individual DNA virus. Sensitivity of the assay was determined with a plasmid containing VZV DNA binding protein gene and another plasmid for HSV-1 DNA polyrnerase gene. False negative results (due to the presence of inhibitor of DNA amplification in CSF samples) were avoided by the inclusion of beta 2-microalobulin primers in the MNC-PCR assay as an internal control. Results: Positive results were obtained in 20 CSF samples (8 HSV-1, 2 HSV-2, 4 CMV, 3 VZV, 3 HSV-1/CMV, CMVNZV and HSV-1/EBV coinfections). The comparison between single PCR and MNC-PCR showed a marked increase in sensitivity of MNC-PCR test, since six negative samples in single PCR proved positive in MNC-PCR (P < 0.005). Sensitivity was determined 1-5 plasmid copies for VZV and 50-100 plasmid copies for HSV-1. Conclusions: The MNC-PCR assay presented in this study can provide a rapid, sensitive and economical method for detection of viral infections and is applicable to small volumes of CSF samples. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:318 / 324
页数:7
相关论文
共 15 条
[1]   Memory cytotoxic T cell responses to viral tegument and regulatory proteins encoded by open reading frames 4, 10, 29, and 62 of varicella-zoster virus [J].
Arvin, AM ;
Sharp, M ;
Moir, M ;
Kinchington, PR ;
Sadeghi-Zadeh, M ;
Ruyechan, WT ;
Hay, J .
VIRAL IMMUNOLOGY, 2002, 15 (03) :507-516
[2]  
BAVILOLYAEE SA, 2003, IRANIAN J BIOTECHNOL, V4, P59
[4]  
DeBiasi RL, 2002, J CLIN VIROL, V25, pS5, DOI 10.1016/S1386-6532(02)00028-8
[5]   Detection and species identification of four human herpesviruses using polymerase chain reaction coupled with restriction endonuclease analysis [J].
Demkin, VV ;
Kruglova, AI ;
Nikolaeva, NP ;
Yurchenko, JV .
JOURNAL OF VIROLOGICAL METHODS, 2002, 103 (02) :121-128
[6]   Multiplex PCR: Optimization and application in diagnostic virology [J].
Elnifro, EM ;
Ashshi, AM ;
Cooper, RJ ;
Klapper, PE .
CLINICAL MICROBIOLOGY REVIEWS, 2000, 13 (04) :559-+
[7]   Comprehensive PCR-based assay for detection and species identification of human herpesviruses [J].
Johnson, G ;
Nelson, S ;
Petric, M ;
Tellier, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (09) :3274-3279
[8]   TRANSCRIPTION FROM VARICELLA-ZOSTER VIRUS GENE-67 (GLYCOPROTEIN-IV) [J].
LING, P ;
KINCHINGTON, PR ;
SADEGHIZADEH, M ;
RUYECHAN, WT ;
HAY, J .
JOURNAL OF VIROLOGY, 1992, 66 (06) :3690-3698
[9]   Multiplex PCR: Rapid DNA cycling in a conventional thermal cycler [J].
Markoulatos, P ;
Siafakas, N ;
Katsorchis, T ;
Moncany, M .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2003, 17 (04) :108-112
[10]   Laboratory diagnosis of common herpesvirus infections of the central nervous system by a multiplex PCR assay [J].
Markoulatos, P ;
Georgopoulou, A ;
Siafakas, N ;
Plakokefalos, E ;
Tzanakaki, G ;
Kourea-Kremastinou, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (12) :4426-4432