Evaluation of redox mediators for amperometric biosensors: Ru-complex modified carbon-paste/enzyme electrodes

被引:46
作者
Ivanova, EV
Sergeeva, VS
Oni, J
Kurzawa, C
Ryabov, AD
Schuhmann, W [1 ]
机构
[1] Ruhr Univ Bochum, D-44780 Bochum, Germany
[2] Moscow MV Lomonosov State Univ, Dept Chem Chem Enzymol, R-119899 Moscow, Russia
关键词
Ru-complex; biosensor; electron transfer; carbon-paste electrode; redox mediator;
D O I
10.1016/S1567-5394(03)00046-X
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The properties of reagentless amperometric biosensors are mainly governed by the interaction of the used redox enzyme and the redox mediators used to facilitate the electron-transfer reaction. Both the used redox mediators and the redox enzymes differ concerning their hydrophilicity and their properties within the matrix of a carbon-paste electrode. Since there is no general procedure which is applicable for any enzyme in combination with any redox mediator, optimisation is necessary for each possible combination. Three approaches for the development of biosensors were investigated using carbon-paste electrodes enriched with redox mediator as a base in all sensor architectures. A class of redox mediators with the common formula Ru(LL)(2)(X)(2) (where LL are 1,10-phenantroline or 2,2'bipyridine type ligands, and X is an acido ligand) was investigated. In the first approach, enzymes were integrated into the carbon paste; in the second, the enzymes were adsorbed on the surface of the mediator-containing carbon-paste electrode and held in place by a Nafion film; and in the third approach, enzymes were entrapped in polymer films, which were electrochemically deposited onto the electrode's surface. The properties of the obtained biosensors strongly depend on the sensor architecture and the specific features of the used enzyme. Thus, our investigation using three different sensor architectures can provide valuable information about the possible interaction between a specific enzyme and a redox mediators with specific properties. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 25 条
[1]  
BASF, Patent No. 0256521
[2]  
BOURDILLON C, 1993, J AM CHEM SOC, V115, P2
[3]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[4]   Enzyme-catalyzed direct electron transfer: Fundamentals and analytical applications [J].
Ghindilis, AL ;
Atanasov, P ;
Wilkins, E .
ELECTROANALYSIS, 1997, 9 (09) :661-674
[5]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[6]  
Habermüller K, 1998, ELECTROANAL, V10, P1281, DOI 10.1002/(SICI)1521-4109(199812)10:18<1281::AID-ELAN1281>3.0.CO
[7]  
2-I
[8]  
Habermüller L, 2000, FRESEN J ANAL CHEM, V366, P560
[9]   SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993 [J].
KALCHER, K ;
KAUFFMANN, JM ;
WANG, J ;
SVANCARA, I ;
VYTRAS, K ;
NEUHOLD, C ;
YANG, Z .
ELECTROANALYSIS, 1995, 7 (01) :5-22
[10]   Immobilization method for the preparation of biosensors based on pH shift-induced deposition of biomolecule-containing polymer films [J].
Kurzawa, C ;
Hengstenberg, A ;
Schuhmann, W .
ANALYTICAL CHEMISTRY, 2002, 74 (02) :355-361