Evaluation of point-of-care maternal glucose measurements for the diagnosis of gestational diabetes mellitus

被引:18
作者
Daly, N. [1 ]
Carroll, C. [1 ]
Flynn, I. [1 ]
Harley, R. [1 ]
Maguire, P. J. [1 ]
Turner, M. J. [1 ]
机构
[1] Coombe Women & Infants Univ Hosp, UCD Ctr Human Reprod, Dublin, Ireland
关键词
Diagnostic accuracy; gestational diabetes mellitus; glycolysis; maternal glycaemia; point-of-care testing; PREGNANCY OUTCOMES; NATIONAL-SURVEY; BLOOD-GLUCOSE; CRITERIA; HYPERGLYCEMIA; MULTICENTER; MANAGEMENT;
D O I
10.1111/1471-0528.14255
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Using updated laboratory standards as the reference, we aimed to compare point-of-care ( POC) maternal capillary glucose testing with the diagnostic accuracy of reference and customary venous samples. Design, setting, population Women screened selectively with a onestep 75-g oral glucose tolerance test ( OGTT) at 24-28 weeks' gestation were conveniently recruited to this prospective observational study. Methods Two venous samples and one capillary sample were taken at each OGTT time point. Venous sample one was a fluoride-EDTA ( FE) tube placed on an ice-slurry until cell separation and analysis within 30 minutes ( reference standard). Venous sample two was transported in a tube containing FE ( without ice) ( customary practice). A capillary sample was used for POC testing. Various cut-off points for the POC sample were examined to evaluate diagnostic accuracy. Main outcome measures The sensitivity, specificity, positive and negative predictive values and accuracy of POC capillary glucose for the diagnosis of GDM. Results Of 108 women, GDM was detected in 47.2% (n = 51), 17.6% (n = 19) and 24.1% (n = 26) using the reference standard, customary practices and POC, respectively (P < 0.001). However, based on adjustment of the POC fasting diagnostic threshold from = 5.1 to = 4.8 mol/ l (aPOC), sensitivity, specificity, PPV, NPV and accuracy improved to 92.5, 76.5, 69.8, 94.5 and 94.5%, respectively. Conclusions POC capillary maternal glucose tests were superior to customary laboratory practices for diagnosing GDM. This has considerable potential, particularly in healthcare settings where facilities for phlebotomy are distant from the laboratory or preanalytical sample handling is substandard.
引用
收藏
页码:1746 / 1752
页数:7
相关论文
共 30 条
[21]   New Consensus Criteria for GDM Problem solved or a Pandora's box? [J].
Moses, Robert G. .
DIABETES CARE, 2010, 33 (03) :690-691
[22]   Integration of local and central laboratory functions in a worldwide multicentre study: Experience from the Hyperglycemia and Adverse Pregnancy Outcome (HAPO) Study [J].
Nesbitt, G. Selby ;
Smye, Michael ;
Sheridan, Brian ;
Lappin, Terence R. J. ;
Trimble, Elisabeth R. .
CLINICAL TRIALS, 2006, 3 (04) :397-407
[23]   Atlantic Diabetes in Pregnancy (DIP): the prevalence and outcomes of gestational diabetes mellitus using new diagnostic criteria [J].
O'Sullivan, E. P. ;
Avalos, G. ;
O'Reilly, M. ;
Dennedy, M. C. ;
Gaffney, G. ;
Dunne, F. .
DIABETOLOGIA, 2011, 54 (07) :1670-1675
[24]  
Rebel Annette, 2012, J Diabetes Sci Technol, V6, P396
[25]   Diagnosing gestational diabetes [J].
Ryan, E. A. .
DIABETOLOGIA, 2011, 54 (03) :480-486
[26]  
Sacks DB, 2002, CLIN CHEM, V48, P436, DOI 10.2337/dc11-9998
[27]  
Sacks DB, GUID REC LAB AN DIAG
[28]   Can capillary whole blood glucose and venous plasma glucose measurements be used interchangeably in diagnosis of diabetes mellitus? [J].
Stahl, M ;
Brandslund, I ;
Jorgensen, LGM ;
Petersen, PH ;
Borch-Johnsen, K ;
Olivarius, ND .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2002, 62 (02) :159-166
[29]  
Tonyushkina Ksenia, 2009, J Diabetes Sci Technol, V3, P971
[30]  
van den Berg S., 2015, Ned Tijdschr Klin Chem Labgeneesk, V40, P68