Bioactive glass and hydroxyapatite thin films obtained by pulsed laser deposition

被引:63
作者
Gyorgy, E.
Grigorescu, S.
Socoi, G.
Mifilailescu, I. N.
Janackovic, D.
Dindune, A.
Kanepe, Z.
PalcevskiSe, E.
Zdrentu, E. L.
Petrescu, S. M.
机构
[1] Inst Ciencia Mat Barcelona, Consejo Super Invest Cientificas, Bellaterra 08193, Spain
[2] Natl Inst Lasers Plasma & Radiat Phys, Bucharest 77125, Romania
[3] Univ Belgrade, Fac Technol & Met, Belgrade 11000, Serbia
[4] Riga Tech Univ, Inst Inorgan Chem, Riga, Latvia
[5] Inst Biochem, Bucharest, Romania
关键词
bioactive glass; calcium hydroxyapatite; pulsed laser deposition;
D O I
10.1016/j.apsusc.2007.02.146
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Bioactive glass (BG), calcium hydroxyapatite (HA), and ZrO2 doped HA thin films were grown by pulsed laser deposition on Ti substrates. An UV KrF* (lambda = 248 nm, tau >= 7 ns) excimer laser was used for the multi-pulse irradiation of the targets. The substrates were kept at room temperature or heated during the film deposition at values within the (400-550 degrees C) range. The depositions were performed in oxygen and water vapor atmospheres, at pressure values in the range (5-40 Pa). The HA coatings were heat post-treated for 6 h in a flux of hot water vapors at the same temperature as applied during deposition. The surface morphology, chemical composition, and crystalline quality of the obtained thin films were studied by scanning electron microscopy, atomic force microscopy, and X-ray diffractometry. The films were seeded for in vitro tests with Hek293 (human embryonic kidney) cells that revealed a good adherence on the deposited layers. Biocompatibility tests showed that cell growth was better on HA than on BG thin films. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:7981 / 7986
页数:6
相关论文
共 36 条
[1]  
[Anonymous], TRENDS BIOMATER ARTI
[2]   Effects of Nb doping on the TiO2 anatase-to-rutile phase transition [J].
Arbiol, J ;
Cerdà, J ;
Dezanneau, G ;
Cirera, A ;
Peiró, F ;
Cornet, A ;
Morante, JR .
JOURNAL OF APPLIED PHYSICS, 2002, 92 (02) :853-861
[3]   ABLATION OF HYDROXYAPATITE BY PULSED LASER IRRADIATION [J].
BAERI, P ;
TORRISI, L ;
MARINO, N ;
FOTI, G .
APPLIED SURFACE SCIENCE, 1992, 54 :210-214
[4]   Osteoblast growth on titanium foils coated with hydroxyapatite by pulsed laser ablation [J].
Ball, MD ;
Downes, S ;
Scotchford, CA ;
Antonov, EN ;
Bagratashvili, VN ;
Popov, VK ;
Lo, WJ ;
Grant, DM ;
Howdle, SM .
BIOMATERIALS, 2001, 22 (04) :337-347
[5]  
Bauerle D., 2011, LASER PROCESSING CHE, V4
[6]  
Brunette D. M., 2001, TITANIUM MED
[7]   Plasma spraying of zirconia-reinforced hydroxyapatite composite coatings on titanium .1. Phase, microstructure and bonding strength [J].
Chang, E ;
Chang, WJ ;
Wang, BC ;
Yang, CY .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (04) :193-200
[8]  
Chrisey D. B., 1994, PULSED LASER DEPOSIT
[9]   Processing and properties of a bioactive glass-ceramic reinforced with ductile silver particles [J].
Claxton, E ;
Taylor, BA ;
Rawlings, RD .
JOURNAL OF MATERIALS SCIENCE, 2002, 37 (17) :3725-3732
[10]   Dissolution behaviour of calcium phosphate coatings obtained by laser ablation [J].
Clèries, L ;
Fernández-Pradas, JM ;
Sardin, G ;
Morenza, JL .
BIOMATERIALS, 1998, 19 (16) :1483-1487