Comparison of the clinical application value of mo-targeted X-ray, color doppler ultrasound and MRI in preoperative comprehensive evaluation of breast cancer

被引:8
作者
Zhang, Hui [1 ]
Guo, Li-li [1 ]
Tao, Wei-jing [1 ]
Zhang, Jian-dong [1 ]
Bai, Gen-ji [1 ]
机构
[1] Nanjing Med Univ, Affiliated Huaian Peoples Hosp 1, Dept Med Imaging, Huaian 223300, Peoples R China
关键词
Breast cancer; Mo-targeted X-ray examination; Color doppler ultrasound; MRI; DIGITAL MAMMOGRAPHY; TOMOSYNTHESIS; METAANALYSIS; ACCURACY;
D O I
10.1016/j.sjbs.2019.09.009
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: To investigate the clinical application value of the Mo-targeted X-ray examination, color Doppler ultrasound and magnetic resonance imaging (MRI) in the diagnosis and preoperative comprehensive evaluation of breast cancer. Methods: Among 170 breast cancer patients, they underwent Mo-targeted X-ray examination, color Doppler ultrasound and MRI before surgery to evaluate the lesions in breast, axillary lymph nodes and the availability of breast-conserving surgery. Results: The detection rates using color Doppler ultrasound examination and MRI were higher than that in the Mo-targeted X-ray examination, which were 90%, 94% and 82%, respectively (P < 0.01 or 0.05). With the result of pathological examination as the golden criteria, we found that specificities of Mo-targeted Xray examination, color Doppler ultrasound examination and MRI in evaluating the metastasis in axillary lymph nodes were similar (85.11%, 77.66% and 79.79%; P > 0.05). Before surgery, the sensitivities and accuracies of the color Doppler ultrasound examination and MRI were higher than those using the Motargeted X-ray examination, which were 73.21%, 82.14%, and 28.57%, 76.00%, 80.67% and 64.00% (P < 0.01 or 0.05). Before surgery, the accuracy rate of MRI in evaluating the breast-conserving surgery was higher than those of Mo-targeted X-ray examination and color Doppler ultrasound (92.00%, 83.33% and 84.67%; P < 0.05). Conclusion: Combined application of Mo-targeted X-ray examination, color Doppler ultrasound and MRI shows a higher accuracy in diagnosis of breast cancer and evaluation of axillary lymph node metastasis, which is conducive to the selection of surgical methods. (C) 2019 Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:1973 / 1977
页数:5
相关论文
共 19 条
[1]   Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study [J].
Ciatto, Stefano ;
Houssami, Nehmat ;
Bernardi, Daniela ;
Caumo, Francesca ;
Pellegrini, Marco ;
Brunelli, Silvia ;
Tuttobene, Paola ;
Bricolo, Paola ;
Fanto, Carmine ;
Valentini, Marvi ;
Montemezzi, Stefania ;
Macaskill, Petra .
LANCET ONCOLOGY, 2013, 14 (07) :583-589
[2]   Breast MRI in clinically and mammographically occult breast cancer presenting with an axillary metastasis: A systematic review [J].
de Bresser, J. ;
de Vos, B. ;
van der Ent, F. ;
Hulsewe, K. .
EJSO, 2010, 36 (02) :114-119
[3]   The Role of Magnetic Resonance Imaging in the Investigation and Management of Invasive Lobular CarcinomaA 3-Year Retrospective Study in Two District General Hospitals [J].
Derias, Mina ;
Subramanian, Ashok ;
Allan, Simon ;
Shah, Elizabeth ;
El Teraifi, Hassan ;
Howlett, David .
BREAST JOURNAL, 2016, 22 (04) :384-389
[4]   Early Clinical Experience with Digital Breast Tomosynthesis for Screening Mammography [J].
Durand, Melissa A. ;
Haas, Brian M. ;
Yao, Xiaopan ;
Geisel, Jaime L. ;
Raghu, Madhavi ;
Hooley, Regina J. ;
Horvath, Laura J. ;
Philpotts, Liane E. .
RADIOLOGY, 2015, 274 (01) :85-92
[5]   Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography [J].
Friedewald, Sarah M. ;
Rafferty, Elizabeth A. ;
Rose, Stephen L. ;
Durand, Melissa A. ;
Plecha, Donna M. ;
Greenberg, Julianne S. ;
Hayes, Mary K. ;
Copit, Debra S. ;
Carlson, Kara L. ;
Cink, Thomas M. ;
Barke, Lora D. ;
Greer, Linda N. ;
Miller, Dave P. ;
Conant, Emily F. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (24) :2499-2507
[6]   Comparison of Tomosynthesis Plus Digital Mammography and Digital Mammography Alone for Breast Cancer Screening [J].
Haas, Brian M. ;
Kalra, Vivek ;
Geisel, Jaime ;
Raghu, Madhavi ;
Durand, Melissa ;
Philpotts, Liane E. .
RADIOLOGY, 2013, 269 (03) :694-700
[7]   Accuracy and surgical impact of magnetic resonance imaging in breast cancer staging: Systematic review and meta-analysis in detection of multifocal and multicentric cancer [J].
Houssami, Nehmat ;
Ciatto, Stefano ;
Macaskill, Petra ;
Lord, Sarah J. ;
Warren, Ruth M. ;
Dixon, J. Michael ;
Irwig, Les .
JOURNAL OF CLINICAL ONCOLOGY, 2008, 26 (19) :3248-3258
[8]   An Individual Person Data Meta-Analysis of Preoperative Magnetic Resonance Imaging and Breast Cancer Recurrence [J].
Houssami, Nehmat ;
Turner, Robin ;
Macaskill, Petra ;
Turnbull, Lindsay W. ;
McCready, David R. ;
Tuttle, Todd M. ;
Vapiwala, Neha ;
Solin, Lawrence J. .
JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (05) :392-U33
[9]   Bilateral Contrast-enhanced Dual-Energy Digital Mammography: Feasibility and Comparison with Conventional Digital Mammography and MR Imaging in Women with Known Breast Carcinoma [J].
Jochelson, Maxine S. ;
Dershaw, D. David ;
Sung, Janice S. ;
Heerdt, Alexandra S. ;
Thornton, Cynthia ;
Moskowitz, Chaya S. ;
Ferrara, Jessica ;
Morris, Elizabeth A. .
RADIOLOGY, 2013, 266 (03) :743-751
[10]   Association of MMP9-1562C/T and MMP13-77A/G Polymorphisms with Non-Small Cell Lung Cancer in Southern Chinese Population [J].
Li, Wen ;
Jia, Ming Xi ;
Wang, Jian Hui ;
Lu, Jie Li ;
Deng, Jing ;
Tang, Jian Xin ;
Liu, Cun .
BIOMOLECULES, 2019, 9 (03)