Passive-bending, short-type single-balloon enteroscope for endoscopic retrograde cholangiopancreatography in Roux-en-Y anastomosis patients

被引:23
作者
Yamauchi, Hiroshi [1 ]
Kida, Mitsuhiro [1 ]
Okuwaki, Kosuke [1 ]
Miyazawa, Shiro [1 ]
Iwai, Tomohisa [1 ]
Tokunaga, Shuko [1 ]
Takezawa, Miyoko [1 ]
Imaizumi, Hiroshi [1 ]
Koizumi, Wasaburo [1 ]
机构
[1] Kitasato Univ East Hosp, Dept Gastroenterol, Sagamihara, Kanagawa 2520380, Japan
关键词
Passive bending; Roux-en-Y anastomosis; Endoscopic retrograde cholangiopancreatography; Short type; Single-balloon enteroscope; COLONOSCOPE; ANATOMY; CHOLANGIOGRAPHY; ERCP;
D O I
10.3748/wjg.v21.i5.1546
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To evaluate short-type-single-balloon enteroscope (SBE) with passive-bending, high-force trans-mission functions for endoscopic retrograde cholangiopancreatography (ERCP) in patients with Roux-en-Y anastomosis. METHODS: Short-type SBE with this technology (SIF-Y0004-V01; working length, 1520 mm; channel diameter, 3.2 mm) was used to perform 50 ERCP procedures in 37 patients with Roux-en-Y anastomosis. The rate of reaching the blind end, time required to reach the blind end, diagnostic and therapeutic success rates, and procedure time and complications were studied retrospectively and compared with the results of 34 sessions of ERCP performed using a short-type SBE without this technology (SIF-Y0004; working length, 1520 mm; channel diameter, 3.2 mm) in 25 patients. RESULTS: The rate of reaching the blind end was 90% with SIF-Y0004-V01 and 91% with SIF-Y0004 (P = 0.59). The median time required to reach the papilla was significantly shorter with SIF-Y0004-V01 than with SIF-Y0004 (16 min vs 24 min, P = 0.04). The diagnostic success rate was 93% with SIF-Y0004-V01 and 84% with SIF-Y0004 (P = 0.17). The therapeutic success rate was 95% with SIF-Y0004-V01 and 96% with SIF-Y0004 (P = 0.68). The median procedure time was 40 min with SIF-Y0004-V01 and 36 min with SIF-Y0004 (P = 0.50). The incidence of hyperamylasemia was 6.0% in the SIF-Y0004-V01 group and 14.7% in the SIF-Y0004 group (P = 0.723). The incidence of pancreatitis was 0% in the SIF-Y0004-V01 group and 5.9% in the SIF-Y0004 group (P > 0.999). The incidence of gastrointestinal perforation was 2.0% (1/50) in the SIF-Y0004-V01 group and 2.9% (1/34) in the SIF-Y0004 group (P > 0.999). CONCLUSION: SIF-Y0004-V01 is useful for ERCP in patients with Roux-en-Y anastomosis and may reduce the time required to reach the blind end.
引用
收藏
页码:1546 / 1553
页数:8
相关论文
共 23 条
[1]   Double-balloon enteroscopy for endoscopic retrograde cholangiography in patients with a Roux-en-Y anastomosis [J].
Aabakken, L. ;
Bretthauer, M. ;
Line, P. D. .
ENDOSCOPY, 2007, 39 (12) :1068-1071
[2]   ENDOSCOPIC SPHINCTEROTOMY COMPLICATIONS AND THEIR MANAGEMENT - AN ATTEMPT AT CONSENSUS [J].
COTTON, PB ;
LEHMAN, G ;
VENNES, J ;
GEENEN, JE ;
RUSSELL, RCG ;
MEYERS, WC ;
LIGUORY, C ;
NICKL, N .
GASTROINTESTINAL ENDOSCOPY, 1991, 37 (03) :383-393
[3]   Reduced pain during screening colonoscopy with an ultrathin colonoscope: a randomized controlled trial [J].
Garborg, K. K. ;
Loberg, M. ;
Matre, J. ;
Holme, O. ;
Kalager, M. ;
Hoff, G. ;
Bretthauer, M. .
ENDOSCOPY, 2012, 44 (08) :740-745
[4]   A case of successful enteroscopic balloon dilation for late anastomotic stricture of choledochojejunostomy after living donor liver transplantation [J].
Haruta, H ;
Yamamoto, H ;
Mizuta, K ;
Kita, Y ;
Uno, T ;
Egami, S ;
Hishikawa, S ;
Sugano, K ;
Kawarasaki, H .
LIVER TRANSPLANTATION, 2005, 11 (12) :1608-1610
[5]   Evaluation of a novel colonoscope designed for easier passage through flexures: A randomized study [J].
Hoff, G ;
Bretthauer, M ;
Huppertz-Hauss, G ;
Sauar, J ;
Paulsen, J ;
Dahler, S ;
Kjellevold, O .
ENDOSCOPY, 2005, 37 (11) :1123-1126
[6]   Long- and short-type double-balloon enteroscopy-assisted therapeutic ERCP for intact papilla in patients with a Roux-en-Y anastomosis [J].
Itoi, Takao ;
Ishii, Kentaro ;
Sofuni, Atsushi ;
Itokawa, Fumihide ;
Tsuchiya, Takayoshi ;
Kurihara, Toshio ;
Tsuji, Shujiro ;
Ikeuchi, Nobuhito ;
Fukuzawa, Katsumasa ;
Moriyasu, Fuminori ;
Tsuchida, Akihiko .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (03) :713-721
[7]   Single-Balloon Enteroscopy-Assisted ERCP in Patients With Billroth II Gastrectomy or Roux-en-Y Anastomosis [J].
Itoi, Takao ;
Ishii, Kentaro ;
Sofuni, Atsushi ;
Itokawa, Fumihide ;
Tsuchiya, Takayoshi ;
Kurihara, Toshio ;
Tsuji, Shujiro ;
Ikeuchi, Nobuhito ;
Umeda, Junko ;
Moriyasu, Fuminori .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (01) :93-99
[8]   DOUBLE BALLOON ENDOSCOPE FACILITATES ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY IN ROUX-EN-Y ANASTOMOSIS PATIENTS [J].
Iwamoto, Sayaka ;
Ryozawa, Shomei ;
Yamamoto, Hironori ;
Taba, Kumiko ;
Ishigaki, Noriko ;
Harano, Megumi ;
Iwano, Hirotoshi ;
Sakaida, Isao .
DIGESTIVE ENDOSCOPY, 2010, 22 (01) :64-68
[9]   Hyperamylasemia of uncertain significance associated with oral double-balloon enteroscopy [J].
Kopacova, Marcela ;
Rejchrt, Stanislav ;
Tacheci, Ilja ;
Bures, Jan .
GASTROINTESTINAL ENDOSCOPY, 2007, 66 (06) :1133-1138
[10]   "Passive-bending colonoscope" significantly improves cecal intubation in difficult cases [J].
Mizukami, Takeshi ;
Ogata, Haruhiko ;
Hibi, Toshihumi .
WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (32) :4454-4456