Effect of confounding variables on hemodynamic response function estimation using averaging and deconvolution analysis: An event-related NIRS study

被引:23
作者
Aarabi, Ardalan [1 ,2 ]
Osharina, Victoria [2 ]
Wallois, Fabrice [2 ,3 ]
机构
[1] Univ Picardie Jules Verne, Fac Med, F-80036 Amiens, France
[2] Univ Hosp, Univ Res Ctr CURS, INSERM, GRAMFC,U1105, F-80054 Amiens, France
[3] CHU AMIENS SITE SUD, EFSN Pediat Pediat Nervous Syst Funct Invest Unit, Amiens, France
关键词
Averaging; Deconvolution method; Finite impulse response; Gamma basis set; Confounding variables; Hemodynamic response function; Near-infrared spectroscopy; Event-related design; NEAR-INFRARED SPECTROSCOPY; TIME-SERIES ANALYSIS; GENERAL LINEAR-MODEL; PHYSIOLOGICAL NOISE; BRAIN ACTIVATION; CEREBRAL HEMODYNAMICS; EXPERIMENTAL-DESIGNS; STATISTICAL-METHODS; OPTICAL TOPOGRAPHY; RESAMPLING METHODS;
D O I
10.1016/j.neuroimage.2017.04.048
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Slow and rapid event-related designs are used in fMRI and functional near-infrared spectroscopy (fNIRS) experiments to temporally characterize the brain hemodynamic response to discrete events. Conventional averaging (CA) and the deconvolution method (DM) are the two techniques commonly used to estimate the Hemodynamic Response Function (HRF) profile in event-related designs. In this study, we conducted a series of simulations using synthetic and real NIRS data to examine the effect of the main confounding factors, including event sequence timing parameters, different types of noise, signal-to-noise ratio (SNR), temporal autocorrelation and temporal filtering on the performance of these techniques in slow and rapid event-related designs. We also compared systematic errors in the estimates of the fitted HRF amplitude, latency and duration for both techniques. We further compared the performance of deconvolution methods based on Finite Impulse Response (FIR) basis functions and gamma basis sets. Our results demonstrate that DM was much less sensitive to confounding factors than CA. Event timing was the main parameter largely affecting the accuracy of CA. In slow event-related designs, deconvolution methods provided similar results to those obtained by CA. In rapid event-related designs, our results showed that DM outperformed CA for all SNR, especially above -5 dB regardless of the event sequence timing and the dynamics of background NIRS activity. Our results also show that periodic low-frequency systemic hemodynamic fluctuations as well as phase-locked noise can markedly obscure hemodynamic evoked responses. Temporal autocorrelation also affected the performance of both techniques by inducing distortions in the time profile of the estimated hemodynamic response with inflated t-statistics, especially at low SNRs. We also found that high-pass temporal filtering could substantially affect the performance of both techniques by removing the low-frequency components of HRF profiles. Our results emphasize the importance of characterization of event timing, background noise and SNR when estimating HRF profiles using CA and DM in event-related designs.
引用
收藏
页码:25 / 49
页数:25
相关论文
共 139 条
  • [81] NONINVASIVE CEREBRAL OPTICAL SPECTROSCOPY FOR MONITORING CEREBRAL OXYGEN DELIVERY AND HEMODYNAMICS
    MCCORMICK, PW
    STEWART, M
    GOETTING, MG
    DUJOVNY, M
    LEWIS, G
    AUSMAN, JI
    [J]. CRITICAL CARE MEDICINE, 1991, 19 (01) : 89 - 97
  • [82] ICA denoising for event-related fMRI studies
    McKeown, Martin J.
    Hu, Yong-jie
    Wang, Z. Jane
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 157 - 161
  • [83] Dynamical model for generating synthetic electrocardiogram signals
    McSharry, PE
    Clifford, GD
    Tarassenko, L
    Smith, LA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (03) : 289 - 294
  • [84] Characterizing the hemodynamic response: Effects of presentation rate, sampling procedure, and the possibility of ordering brain activity based on relative timing
    Miezin, FM
    Maccotta, L
    Ollinger, JM
    Petersen, SE
    Buckner, RL
    [J]. NEUROIMAGE, 2000, 11 (06) : 735 - 759
  • [85] Cerebral and systemic hemodynamic changes during cognitive and motor activation paradigms
    Moody, M
    Panerai, RB
    Eames, PJ
    Potter, JF
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2005, 288 (06) : R1581 - R1588
  • [86] Mulert Christoph., 2014, MRI in Psychiatry
  • [87] Orthogonalization of Regressors in fMRI Models
    Mumford, Jeanette A.
    Poline, Jean-Baptiste
    Poldrack, Russell A.
    [J]. PLOS ONE, 2015, 10 (04):
  • [88] Deconvolving BOLD activation in event-related designs for multivoxel pattern classification analyses
    Mumford, Jeanette A.
    Turner, Benjamin O.
    Ashby, F. Gregory
    Poldrack, Russell A.
    [J]. NEUROIMAGE, 2012, 59 (03) : 2636 - 2643
  • [89] Correlation of visual-evoked hemodynamic responses and potentials in human brain
    Nasi, Tiina
    Kotilahti, Kalle
    Noponen, Tommi
    Nissila, Ilkka
    Lipiainen, Lauri
    Merilainen, Pekka
    [J]. EXPERIMENTAL BRAIN RESEARCH, 2010, 202 (03) : 561 - 570
  • [90] Spontaneous low frequency oscillations of cerebral hemodynamics and metabolism in human adults
    Obrig, H
    Neufang, M
    Wenzel, R
    Kohl, M
    Steinbrink, J
    Einhäupl, K
    Villringer, A
    [J]. NEUROIMAGE, 2000, 12 (06) : 623 - 639