Effect of confounding variables on hemodynamic response function estimation using averaging and deconvolution analysis: An event-related NIRS study

被引:23
作者
Aarabi, Ardalan [1 ,2 ]
Osharina, Victoria [2 ]
Wallois, Fabrice [2 ,3 ]
机构
[1] Univ Picardie Jules Verne, Fac Med, F-80036 Amiens, France
[2] Univ Hosp, Univ Res Ctr CURS, INSERM, GRAMFC,U1105, F-80054 Amiens, France
[3] CHU AMIENS SITE SUD, EFSN Pediat Pediat Nervous Syst Funct Invest Unit, Amiens, France
关键词
Averaging; Deconvolution method; Finite impulse response; Gamma basis set; Confounding variables; Hemodynamic response function; Near-infrared spectroscopy; Event-related design; NEAR-INFRARED SPECTROSCOPY; TIME-SERIES ANALYSIS; GENERAL LINEAR-MODEL; PHYSIOLOGICAL NOISE; BRAIN ACTIVATION; CEREBRAL HEMODYNAMICS; EXPERIMENTAL-DESIGNS; STATISTICAL-METHODS; OPTICAL TOPOGRAPHY; RESAMPLING METHODS;
D O I
10.1016/j.neuroimage.2017.04.048
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Slow and rapid event-related designs are used in fMRI and functional near-infrared spectroscopy (fNIRS) experiments to temporally characterize the brain hemodynamic response to discrete events. Conventional averaging (CA) and the deconvolution method (DM) are the two techniques commonly used to estimate the Hemodynamic Response Function (HRF) profile in event-related designs. In this study, we conducted a series of simulations using synthetic and real NIRS data to examine the effect of the main confounding factors, including event sequence timing parameters, different types of noise, signal-to-noise ratio (SNR), temporal autocorrelation and temporal filtering on the performance of these techniques in slow and rapid event-related designs. We also compared systematic errors in the estimates of the fitted HRF amplitude, latency and duration for both techniques. We further compared the performance of deconvolution methods based on Finite Impulse Response (FIR) basis functions and gamma basis sets. Our results demonstrate that DM was much less sensitive to confounding factors than CA. Event timing was the main parameter largely affecting the accuracy of CA. In slow event-related designs, deconvolution methods provided similar results to those obtained by CA. In rapid event-related designs, our results showed that DM outperformed CA for all SNR, especially above -5 dB regardless of the event sequence timing and the dynamics of background NIRS activity. Our results also show that periodic low-frequency systemic hemodynamic fluctuations as well as phase-locked noise can markedly obscure hemodynamic evoked responses. Temporal autocorrelation also affected the performance of both techniques by inducing distortions in the time profile of the estimated hemodynamic response with inflated t-statistics, especially at low SNRs. We also found that high-pass temporal filtering could substantially affect the performance of both techniques by removing the low-frequency components of HRF profiles. Our results emphasize the importance of characterization of event timing, background noise and SNR when estimating HRF profiles using CA and DM in event-related designs.
引用
收藏
页码:25 / 49
页数:25
相关论文
共 139 条
  • [1] Characterization of the relative contributions from systemic physiological noise to whole-brain resting-state functional near-infrared spectroscopy data using single-channel independent component analysis
    Aarabi, Ardalan
    Huppert, Theodore J.
    [J]. NEUROPHOTONICS, 2016, 3 (02)
  • [2] Detection of EEG transients in neonates and older children using a system based on dynamic time-warping template matching and spatial dipole clustering
    Aarabi, Ardalan
    Kazemi, Kamran
    Grebe, Reinhard
    Moghaddam, Hamid Abrishami
    Wallois, Fabrice
    [J]. NEUROIMAGE, 2009, 48 (01) : 50 - 62
  • [3] Real-time imaging of human brain function by near-infrared spectroscopy using an adaptive general linear model
    Abdelnour, A. Farras
    Huppert, Theodore
    [J]. NEUROIMAGE, 2009, 46 (01) : 133 - 143
  • [4] The variability of human, BOLD hemodynamic responses
    Aguirre, GK
    Zarahn, E
    D'Esposito, M
    [J]. NEUROIMAGE, 1998, 8 (04) : 360 - 369
  • [5] [Anonymous], 2006, STAT PARAMETRIC MAPP
  • [6] Autoregressive model based algorithm for correcting motion and serially correlated errors in fNIRS
    Barker, Jeffrey W.
    Aarabi, Ardalan
    Huppert, Theodore J.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2013, 4 (08): : 1366 - 1379
  • [7] Detection versus estimation in event-related fMRI: Choosing the optimal stimulus timing
    Birn, RM
    Cox, RW
    Bandettini, PA
    [J]. NEUROIMAGE, 2002, 15 (01) : 252 - 264
  • [8] Separating respiratory-variation-related neuronal-activity-related fluctuations in fluctuations from fMRI
    Birn, RM
    Diamond, JB
    Smith, MA
    Bandettini, PA
    [J]. NEUROIMAGE, 2006, 31 (04) : 1536 - 1548
  • [9] FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI
    BISWAL, B
    YETKIN, FZ
    HAUGHTON, VM
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 537 - 541
  • [10] Diffuse optical imaging of brain activation: approaches to optimizing image sensitivity, resolution, and accuracy
    Boas, DA
    Dale, AM
    Franceschini, MA
    [J]. NEUROIMAGE, 2004, 23 : S275 - S288