Prospective Motion Correction and Selective Reacquisition Using Volumetric Navigators for Vessel-Encoded Arterial Spin Labeling Dynamic Angiography

被引:12
|
作者
Frost, Robert [1 ]
Hess, Aaron T. [2 ]
Okell, Thomas W. [1 ]
Chappell, Michael A. [1 ,3 ]
Tisdall, M. Dylan [4 ,5 ]
van der Kouwe, Andre J. W. [4 ,5 ]
Jezzard, Peter [1 ]
机构
[1] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB Ctr, Oxford, England
[2] Univ Oxford, Div Cardiovasc Med, Radcliffe Dept Med, Oxford Ctr Clin Magnet Resonance Res, Oxford, England
[3] Univ Oxford, Inst Biomed Engn, Oxford, England
[4] Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Charlestown, MA USA
[5] Harvard Med Sch, Dept Radiol, Boston, MA USA
关键词
prospective motion correction; volumetric navigator; pseudo-continuous arterial spin labeling; magnetic resonance angiography; vessel-encoded angiography; reacquisition; HEAD MOTION; MR-ANGIOGRAPHY; BLOOD-FLOW; TRACKING; ARTIFACTS; ECHOES;
D O I
10.1002/mrm.26040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to improve robustness to motion in a vessel-encoded angiography sequence used for patient scans. The sequence is particularly sensitive to motion between imaging segments, which causes ghosting and blurring that propagates to the final angiogram. Methods: Volumetric echo planar imaging (EPI) navigators acquired in 275 ms were inserted after the imaging readout in a vessel-encoded pseudo-continuous arterial spin labeling (VEPCASL) sequence. The effects of movement between segments on the images were tested with phantom experiments. Deliberate motion experiments with healthy volunteers were performed to compare prospective motion correction (PMC) with reacquisition versus no correction. Results: In scans without motion, the addition of the EPI navigator to the sequence did not affect the quality of the angiograms in comparison with the original sequence. PMC and reacquisition improved the visibility of vessels in the angiograms compared with the scans without correction. The reacquisition strategy was shown to be important for complete correction of imaging artifacts. Conclusion: We have demonstrated an effective method to correct motion in vessel-encoded angiography. For reacquisition of 15 segments, the technique requires approximately 30 s of additional scanning (similar to 25%). (C) 2015 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1420 / 1430
页数:11
相关论文
共 50 条
  • [1] A kinetic model for vessel-encoded dynamic angiography with arterial spin labeling
    Okell, Thomas W.
    Chappell, Michael A.
    Schulz, Ursula G.
    Jezzard, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 969 - 979
  • [2] Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI
    Tisdall, M. Dylan
    Hess, Aaron T.
    Reuter, Martin
    Meintjes, Ernesta M.
    Fischl, Bruce
    van der Kouwe, Andre J. W.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) : 389 - 399
  • [3] RETRACTED: Vessel-Encoded Dynamic Magnetic Resonance Angiography Using Arterial Spin Labeling (Retracted Article)
    Okell, Thomas W.
    Chappell, Michael A.
    Woolrich, Mark W.
    Guenther, Matthias
    Feinberg, David A.
    Jezzard, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 430 - 438
  • [4] Vessel-encoded arterial spin-labeling using pseudocontinuous tagging
    Wong, Eric C.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1086 - 1091
  • [5] Vessel-encoded dynamic magnetic resonance angiography using arterial spin labeling (Retraction of vol 64, pg 698, 2010)
    Okell, Thomas W.
    Chappell, Michael A.
    Woolrich, Mark W.
    Guenther, Matthias
    Feinberg, David A.
    Jezzard, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (03) : 900 - 900
  • [6] Cerebral blood flow quantification using vessel-encoded arterial spin labeling
    Okell, Thomas W.
    Chappell, Michael A.
    Kelly, Michael E.
    Jezzard, Peter
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2013, 33 (11): : 1716 - 1724
  • [7] Optimization of the spatial modulation function of vessel-encoded pseudo-continuous arterial spin labeling and its application to dynamic angiography
    Suzuki, Yuriko
    van Osch, Matthias J. P.
    Fujima, Noriyuki
    Okell, Thomas W.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 410 - 423
  • [8] An Optimized Encoding Scheme for Planning Vessel-Encoded Pseudocontinuous Arterial Spin Labeling
    Berry, Eleanor S. K.
    Jezzard, Peter
    Okell, Thomas W.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) : 1248 - 1256
  • [9] Measurement of collateral perfusion in acute stroke: a vessel-encoded arterial spin labeling study
    Okell, Thomas W.
    Harston, George W. J.
    Chappell, Michael A.
    Sheerin, Fintan
    Kennedy, James
    Jezzard, Peter
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] Measurement of collateral perfusion in acute stroke: a vessel-encoded arterial spin labeling study
    Thomas W. Okell
    George W. J. Harston
    Michael A. Chappell
    Fintan Sheerin
    James Kennedy
    Peter Jezzard
    Scientific Reports, 9