Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID: Simulations and experiments

被引:9
作者
Li, Bo [1 ,2 ,3 ]
Dong, Hui [2 ,3 ]
Huang, Xiao-Lei [2 ,3 ,4 ]
Qiu, Yang [1 ,2 ,3 ]
Tao, Quan [2 ,3 ]
Zhu, Jian-Ming [1 ]
机构
[1] China Jiliang Univ, Hangzhou 310018, Zhejiang, Peoples R China
[2] Chinese Acad Sci, SIMIT, State Key Lab Funct Mat Informat, Shanghai 200050, Peoples R China
[3] CAS Ctr ExcelleNce Superconducting Elect CENSE, Shanghai 200050, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
shielding effectiveness; aluminum shielded room; eddy current cancellation technique; superconducting quantum interference device; ultra-low-field magnetic resonance imaging; MICROTESLA MRI; MU-T;
D O I
10.1088/1674-1056/27/2/020701
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The aluminum shielded room has been an important part of ultra-low-field magnetic resonance imaging (ULF MRI) based on the superconducting quantum interference device (SQUID). The shielded room is effective to attenuate the external radio-frequency field and keep the extremely sensitive detector, SQUID, working properly. A high-performance shielded room can increase the signal-to-noise ratio (SNR) and improve image quality. In this study, a circular coil with a diameter of 50 cm and a square coil with a side length of 2.0 m was used to simulate the magnetic fields from the nearby electric apparatuses and the distant environmental noise sources. The shielding effectivenesses (SE) of the shielded room with different thicknesses of aluminum sheets were calculated and simulated. A room using 6-mm-thick aluminum plates with a dimension of 1.5 m x 1.5 m x 2.0 m was then constructed. The SE was experimentally measured by using three-axis SQUID magnetometers, with tranisent magnetic field induced in the aluminum plates by the strong pre-polarization pulses. The results of the measured SE agreed with that from the simulation. In addition, the introduction of a 0.5-mm gap caused the obvious reduction of SE indicating the importance of door design. The nuclear magnetic resonance (NMR) signals of water at 5.9 kHz were measured in free space and in a shielded room, and the SNR was improved from 3 to 15. The simulation and experimental results will help us design an aluminum shielded room which satisfies the requirements for future ULF human brain imaging. Finally, the cancellation technique of the transient eddy current was tried, the simulation of the cancellation technique will lead us to finding an appropriate way to suppress the eddy current fields.
引用
收藏
页数:7
相关论文
共 22 条
[1]   SCATTERING OF ELECTROMAGNETIC WAVES FROM 2 CONCENTRIC SPHERES [J].
ADEN, AL ;
KERKER, M .
JOURNAL OF APPLIED PHYSICS, 1951, 22 (10) :1242-1246
[2]   Ultra-low field magnetic resonance imaging detection with gradient tensor compensation in urban unshielded environment [J].
Dong, Hui ;
Qiu, Longqing ;
Shi, Wen ;
Chang, Baolin ;
Qiu, Yang ;
Xu, Lu ;
Liu, Chao ;
Zhang, Yi ;
Krause, Hans-Joachim ;
Offenhaeusser, Andreas ;
Xie, Xiaoming .
APPLIED PHYSICS LETTERS, 2013, 102 (10)
[3]  
Hatridge MJ, 2010, THESIS
[4]   Study on signal intensity of low field nuclear magnetic resonance via an indirect coupling measurement [J].
Jiang Feng-Ying ;
Wang Ning ;
Jin Yi-Rong ;
Deng Hui ;
Tian Ye ;
Lang Pei-Lin ;
Li Jie ;
Chen Ying-Fei ;
Zheng Dong-Ning .
CHINESE PHYSICS B, 2013, 22 (04)
[5]   The Effect of Low Frequency External Field Disturbance on the SQUID Based Ultra-Low Field NMR Measurements [J].
Jin, Y. R. ;
Wang, N. ;
Li, S. ;
Tian, Y. ;
Ren, Y. F. ;
Wu, Y. L. ;
Deng, H. ;
Chen, Y. F. ;
Li, J. ;
Tian, H. Y. ;
Chen, G. H. ;
Zheng, D. N. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) :518-521
[6]   SQUID-detected MRI at 132 μT with T1-weighted contrast established at 10 μT-300 mT [J].
Lee, SK ;
Mössle, M ;
Myers, W ;
Kelso, N ;
Trabesinger, AH ;
Pines, A ;
Clarke, J .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) :9-14
[7]   MAGNETIC-SHIELD FOR WIDE-BANDWIDTH MAGNETIC MEASUREMENTS FOR NONDESTRUCTIVE TESTING AND BIOMAGNETISM [J].
MA, YP ;
WIKSWO, JP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (11) :2654-2661
[8]   NOVEL APPROACHES TO LOW-COST MRI [J].
MACOVSKI, A ;
CONOLLY, S .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :221-230
[9]   SQUID-detected microtesla MRI in the presence of metal [J].
Mössle, M ;
Han, SI ;
Myers, WR ;
Lee, SK ;
Kelso, N ;
Hatridge, M ;
Pines, A ;
Clarke, J .
JOURNAL OF MAGNETIC RESONANCE, 2006, 179 (01) :146-151
[10]   Calculated signal-to-noise ratio of MRI detected with SQUIDs and Faraday detectors in fields from 10 μT to 1.5 T [J].
Myers, Whittier ;
Slichter, Daniel ;
Hatridge, Michael ;
Busch, Sarah ;
Moessle, Michael ;
McDermott, Robert ;
Trabesinger, Andreas ;
Clarke, John .
JOURNAL OF MAGNETIC RESONANCE, 2007, 186 (02) :182-192