The effects of ventilation and building characteristics on indoor air quality in waterpipe cafes

被引:10
|
作者
Rostami, Roohollah [1 ]
Naddafi, Kazem [2 ]
Arfaeinia, Hossein [3 ,4 ]
Nazmara, Shahrokh [2 ]
Fazlzadeh, Mehdi [2 ,5 ]
Saranjam, Behzad [6 ,7 ]
机构
[1] Semnan Univ Med Sci, Res Ctr Hlth Sci & Technol, Semnan, Iran
[2] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[3] Bushehr Univ Med Sci, Persian Gulf Biomed Sci Res Inst, Syst Environm Hlth & Energy Res Ctr, Bushehr, Iran
[4] Bushehr Univ Med Sci, Sch Hlth & Nutr, Dept Environm Hlth Engn, Bushehr, Iran
[5] Ardabil Univ Med Sci, Social Determinants Hlth Res Ctr, Ardebil, Iran
[6] Ardabil Univ Med Sci, Sch Publ Hlth, Dept Occupat Hlth Engn, Ardebil, Iran
[7] Ardabil Univ Med Sci, Hlth Sci Res Ctr, Ardebil, Iran
关键词
Particulate matter; CO; Smoking; Ventilation; Indoor air quality; CARBON-MONOXIDE; PARTICULATE MATTER; EXPOSURE; SMOKING; NICOTINE; SHISHA; BTEX; RISK; CO;
D O I
10.1038/s41370-020-0240-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the concentration of carbon monoxide (CO) and particulate matter (PMs), indoor air samples were collected from 60 waterpipe cafes in Ardabil city of Iran. Moreover, the influence of several structural, operational, and ventilation system were evaluated on the concentration of the selected pollutants. The results showed that the mean concentration of CO (12.0 +/- 7.2 mg/m(3)) and PMs (PM1 = 171.5 +/- 119.6 mu g/m(3), PM2.5 = 303.3 +/- 201.9 mu g/m(3), PM10 = 440.3 +/- 272.2 mu g/m(3)) were notably higher than the guideline levels. According to the results, open face/cafe area was influenced by the natural ventilation rate and the mean air exchange rate was 3.1 +/- 1.1 min(-1). The natural ventilation has a functional role on air quality of the cafes, and fan-type mechanical ventilation was influencing factor on CO concentration when the natural ventilation was restricted. "Type of used charcoal" had the highest influence on the releasing of pollutants inside the cafes as the pollutant concentrations were lower for simple (raw) charcoal compared with the favored (aromatic) one. The results indicated that the building characteristics and natural ventilation considerably affect air quality of the cafes.
引用
收藏
页码:805 / 813
页数:9
相关论文
共 50 条
  • [41] Cooling Performance and Indoor Air Quality Characteristics of an Earth Air Tunnel Cooled Building
    Samuel, D. G. Leo
    Nagendra, S. M. Shiva
    Maiya, M. P.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2018, 33 (02): : 147 - 158
  • [42] Indoor air quality of a hospital building
    Myojo, Toshihiko
    Oyabu, Takako
    Lee, Byeong Woo
    Okada, Takami
    Ishimatsu, Sumiyo
    Matsuu, Satomi
    29TH SYMPOSIUM ON AEROSOL SCIENCE AND TECHNOLOGY, 2012, 2012, : 219 - 220
  • [43] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [44] Ventilation and Indoor Air Quality in Residential Bedrooms
    Fritz, Hagen
    Kinney, Kerry
    Schnyer, David
    Nagy, Zoltan
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 500 - 508
  • [45] Ventilation strategies to improve indoor air quality
    Luo, Q
    Tang, G
    Huang, W
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3313 - 3317
  • [46] VENTILATION FOR ACCEPTABLE INDOOR AIR-QUALITY
    JANSSEN, JE
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1989, 31 (10): : 40 - &
  • [47] EFFECTS OF POULTRY BUILDING DESIGN ON INDOOR AIR QUALITY IN HUMID CLIMATES
    Polat, H. E.
    JOURNAL OF ANIMAL AND PLANT SCIENCES, 2015, 25 (05): : 1264 - 1272
  • [48] Air pollutants associated with smoking in indoor/outdoor of waterpipe cafes in Tehran, Iran: Concentrations, affecting factors and health risk assessment
    Masjedi, Mohammad Reza
    Taghizadeh, Farhad
    Hamzehali, Sanaz
    Ghaffari, Sonia
    Fazlzadeh, Mehdi
    Jafari, Ahmad Jonidi
    Niazi, Sadegh
    Mehrizi, Ehsan Abouee
    Moradi, Masoud
    Pasalari, Hasan
    Arfaeinia, Hossein
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [49] The Effects of an Adaptive Ventilation Control System on Indoor Air Quality and Energy Consumption
    Vasile, Vasilica
    Iordache, Vlad
    Radu, Valentin Mihai
    Petcu, Cristian
    Dragomir, Claudiu-Sorin
    SUSTAINABILITY, 2024, 16 (22)
  • [50] Indoor air quality in the Swedish housing stock and its dependence on building characteristics
    Langer, Sarka
    Beko, Gabriel
    BUILDING AND ENVIRONMENT, 2013, 69 : 44 - 54