The effects of ventilation and building characteristics on indoor air quality in waterpipe cafes

被引:10
|
作者
Rostami, Roohollah [1 ]
Naddafi, Kazem [2 ]
Arfaeinia, Hossein [3 ,4 ]
Nazmara, Shahrokh [2 ]
Fazlzadeh, Mehdi [2 ,5 ]
Saranjam, Behzad [6 ,7 ]
机构
[1] Semnan Univ Med Sci, Res Ctr Hlth Sci & Technol, Semnan, Iran
[2] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[3] Bushehr Univ Med Sci, Persian Gulf Biomed Sci Res Inst, Syst Environm Hlth & Energy Res Ctr, Bushehr, Iran
[4] Bushehr Univ Med Sci, Sch Hlth & Nutr, Dept Environm Hlth Engn, Bushehr, Iran
[5] Ardabil Univ Med Sci, Social Determinants Hlth Res Ctr, Ardebil, Iran
[6] Ardabil Univ Med Sci, Sch Publ Hlth, Dept Occupat Hlth Engn, Ardebil, Iran
[7] Ardabil Univ Med Sci, Hlth Sci Res Ctr, Ardebil, Iran
关键词
Particulate matter; CO; Smoking; Ventilation; Indoor air quality; CARBON-MONOXIDE; PARTICULATE MATTER; EXPOSURE; SMOKING; NICOTINE; SHISHA; BTEX; RISK; CO;
D O I
10.1038/s41370-020-0240-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the concentration of carbon monoxide (CO) and particulate matter (PMs), indoor air samples were collected from 60 waterpipe cafes in Ardabil city of Iran. Moreover, the influence of several structural, operational, and ventilation system were evaluated on the concentration of the selected pollutants. The results showed that the mean concentration of CO (12.0 +/- 7.2 mg/m(3)) and PMs (PM1 = 171.5 +/- 119.6 mu g/m(3), PM2.5 = 303.3 +/- 201.9 mu g/m(3), PM10 = 440.3 +/- 272.2 mu g/m(3)) were notably higher than the guideline levels. According to the results, open face/cafe area was influenced by the natural ventilation rate and the mean air exchange rate was 3.1 +/- 1.1 min(-1). The natural ventilation has a functional role on air quality of the cafes, and fan-type mechanical ventilation was influencing factor on CO concentration when the natural ventilation was restricted. "Type of used charcoal" had the highest influence on the releasing of pollutants inside the cafes as the pollutant concentrations were lower for simple (raw) charcoal compared with the favored (aromatic) one. The results indicated that the building characteristics and natural ventilation considerably affect air quality of the cafes.
引用
收藏
页码:805 / 813
页数:9
相关论文
共 50 条
  • [1] The effects of ventilation and building characteristics on indoor air quality in waterpipe cafés
    Roohollah Rostami
    Kazem Naddafi
    Hossein Arfaeinia
    Shahrokh Nazmara
    Mehdi Fazlzadeh
    Behzad Saranjam
    Journal of Exposure Science & Environmental Epidemiology, 2020, 30 : 805 - 813
  • [2] Indoor air quality in Virginia waterpipe cafes
    Cobb, Caroline Oates
    Vansickel, Andrea Rae
    Blank, Melissa D.
    Jentink, Kade
    Travers, Mark J.
    Eissenberg, Thomas
    TOBACCO CONTROL, 2013, 22 (05) : 338 - 343
  • [3] Indoor air quality in waterpipe cafes: exposure level to particulate matter
    Naddafi, Kazem
    Nabizadeh, Ramin
    Rostamy, Roohollah
    Kalan, Mohammad Ebrahimi
    Hassanvand, Mohammad Sadegh
    Fazlzadeh, Mehdi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (26) : 26605 - 26616
  • [4] Air quality and presence of air ventilation systems inside waterpipe cafes in North Carolina
    Seidenberg, Andrew B.
    Orlan, Elizabeth N.
    Travers, Mark J.
    Sutfin, Erin L.
    TOBACCO CONTROL, 2019, 28 (03) : 356 - 358
  • [5] Formaldehyde and acetaldehyde in the indoor air of waterpipe cafes: Measuring exposures and assessing health effects
    Naddafi, Kazem
    Nabizadeh, Ramin
    Rostami, Roohollah
    Ghaffari, Hamid Reza
    Fazlzadeh, Mehdi
    BUILDING AND ENVIRONMENT, 2019, 165
  • [6] BTEX in indoor air of waterpipe cafes: Levels and factors influencing their concentrations
    Hazrati, Sadegh
    Rostami, Roohollah
    Fazlzadeh, Mehdi
    SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 524 : 347 - 353
  • [7] BUILDING VENTILATION AND INDOOR AIR-QUALITY
    BERK, JV
    AMERICAN CERAMIC SOCIETY BULLETIN, 1980, 59 (03): : 327 - 327
  • [8] THE EFFECTS OF REDUCED VENTILATION ON INDOOR AIR-QUALITY IN AN OFFICE BUILDING
    TURIEL, I
    HOLLOWELL, CD
    MIKSCH, RR
    RUDY, JV
    YOUNG, RA
    COYE, MJ
    ATMOSPHERIC ENVIRONMENT, 1983, 17 (01) : 51 - 64
  • [9] Exposure and risk assessment of PAHs in indoor air of waterpipe cafes in Ardebil, Iran
    Rostami, Roohollah
    Zarei, Ahmad
    Saranjam, Behzad
    Ghaffari, Hamid Reza
    Hazrati, Sadegh
    Poureshg, Yusef
    Fazlzadeh, Mehdi
    BUILDING AND ENVIRONMENT, 2019, 155 : 47 - 57
  • [10] EFFECTIVENESS OF INDOOR AIR QUALITY IMPROVEMENT WITH OUTDOOR AIR FOR BUILDING VENTILATION
    Wang, J.
    Zhang, X.
    Zhou, X.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 417 - 421