Image-scoring system for umbilical and uterine artery pulsed-wave Doppler ultrasound measurement

被引:16
作者
Molloholli, M. [1 ,2 ]
Napolitano, R. [1 ,2 ]
Ohuma, E. O. [1 ,3 ]
Ash, S. [1 ,2 ]
Wanyonyi, S. Z. [1 ,2 ]
Cavallaro, A. [1 ,2 ]
Giudicepietro, A. [1 ,2 ]
Barros, F. [4 ,5 ]
Carvalho, M. [6 ]
Norris, S. [7 ]
Min, A. M. [8 ]
Zainab, G. [9 ]
Papageorghiou, A. T. [1 ,2 ]
机构
[1] Univ Oxford, Nuffield Dept Womens & Reprod Hlth, Oxford, England
[2] Univ Oxford, Green Templeton Coll, Oxford Maternal & Perinatal Hlth Inst, Oxford, England
[3] Univ Oxford, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Ctr Stat Med, Oxford, England
[4] Univ Fed Pelotas, Programa Posgrad Epidemiol, Pelotas, Brazil
[5] Univ Catolica Pelotas, Programa Posgrad Saude & Comportamento, Pelotas, Brazil
[6] Aga Khan Univ, Fac Hlth Sci, Nairobi, Kenya
[7] Univ Witwatersrand, Dept Pediat & Child Hlth, Dev Pathways Hlth Res Unit, Johannesburg, South Africa
[8] Mahidol Univ, Fac Trop Med, Mahidol Oxford Trop Med Res Unit, Shoklo Malaria Res Unit, Mae Sot, Thailand
[9] Aga Khan Univ Hosp, Dept Pediat & Child Hlth, Karachi, Pakistan
基金
比尔及梅琳达.盖茨基金会;
关键词
growth restriction; image scoring; quality control; reproducibility; umbilical artery Doppler; uterine artery Doppler; FETAL-GROWTH STANDARDS; QUALITY-CONTROL; ULTRASONOGRAPHY; CORD;
D O I
10.1002/uog.19101
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To develop an objective image-scoring system for pulsed-wave Doppler measurement of maternal uterine and fetal umbilical arteries, and evaluate how this compares with subjective assessment. Methods As an extension to the INTERGROWTH-21st Project, we developed a scoring system based on six predefined criteria for uterine and umbilical artery pulsed-wave Doppler measurements. Objective evaluation using the scoring system was compared with subjective assessment which consisted of classifying an image as simply acceptable or unacceptable. Based on sample size estimation, a total of 120 umbilical and uterine artery Doppler images were selected randomly from the INTERGROWTH-21st image database. Two independent reviewers evaluated all images in a blinded fashion, both subjectively and using the six-point scoring system. Percentage agreement and kappa statistic were compared between the two methods. Results The overall agreement between reviewers was higher for objective assessment using the scoring system (agreement, 85%; adjusted kappa, 0.70) than for subjective assessment (agreement, 70%; adjusted kappa, 0.47). For the six components of the scoring system, the level of agreement (adjusted kappa) was 0.97 for anatomical site, 0.88 for sweep speed, 0.77 for magnification, 0.68 for velocity scale, 0.68 for image clarity and 0.65 for angle of insonation. Conclusion In quality assessment of umbilical and uterine artery pulsed-wave Doppler measurements, our proposed objective six-point image-scoring system is associated with greater reproducibility than is subjective assessment. We recommend this as the preferred method for quality control, auditing and teaching. Copyright (c) 2018 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 25 条
[1]   The Distribution of Clinical Phenotypes of Preterm Birth Syndrome Implications for Prevention [J].
Barros, Fernando C. ;
Papageorghiou, Aris T. ;
Victora, Cesar G. ;
Noble, Julia A. ;
Pang, Ruyan ;
Lams, Jay ;
Ismail, Leila Cheikh ;
Goldenberg, Robert L. ;
Lambert, Ann ;
Kramer, Michael S. ;
Carvalho, Maria ;
Conde-Agudelo, Agustin ;
Jaffer, Yasmin A. ;
Bertino, Enrico ;
Gravett, Michael G. ;
Altman, Doug G. ;
Ohuma, Eric O. ;
Purwar, Manorama ;
Frederick, Lhunnaya O. ;
Bhutta, Zulfigar A. ;
Kennedy, Stephen H. ;
Villar, Jose .
JAMA PEDIATRICS, 2015, 169 (03) :220-229
[2]   ISUOG Practice Guidelines: use of Doppler ultrasonography in obstetrics [J].
Bhide, A. ;
Acharya, G. ;
Bilardo, C. M. ;
Brezinka, C. ;
Cafici, D. ;
Hernandez-Andrade, E. ;
Kalache, K. ;
Kingdom, J. ;
Kiserud, T. ;
Lee, W. ;
Lees, C. ;
Leung, K. Y. ;
Malinger, G. ;
Mari, G. ;
Prefumo, F. ;
Sepulveda, W. ;
Trudinger, B. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 41 (02) :234-240
[3]   DOPPLER ULTRASONOGRAPHY OF THE UMBILICAL-CORD IN COMPLICATED PREGNANCIES [J].
BRUNER, JB ;
LEVY, DW ;
ARGER, PH .
SOUTHERN MEDICAL JOURNAL, 1993, 86 (04) :418-422
[4]   DOPPLER ULTRASONOGRAPHY OF THE UMBILICAL-CORD IN NORMAL-PREGNANCY [J].
BRUNER, JP ;
GABBE, SG ;
LEVY, DW ;
ARGER, PH .
SOUTHERN MEDICAL JOURNAL, 1993, 86 (01) :52-55
[5]   BIAS, PREVALENCE AND KAPPA [J].
BYRT, T ;
BISHOP, J ;
CARLIN, JB .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1993, 46 (05) :423-429
[6]   Quality control of ultrasound for fetal biometry: results from the INTERGROWTH-21st Project [J].
Cavallaro, A. ;
Ash, S. T. ;
Napolitano, R. ;
Wanyonyi, S. ;
Ohuma, E. O. ;
Molloholli, M. ;
Sande, J. ;
Sarris, I. ;
Ioannou, C. ;
Norris, T. ;
Donadono, V. ;
Carvalho, M. ;
Purwar, M. ;
Barros, F. C. ;
Jaffer, Y. A. ;
Bertino, E. ;
Pang, R. ;
Gravett, M. G. ;
Salomon, L. J. ;
Noble, J. A. ;
Altman, D. G. ;
Papageorghiou, A. T. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2018, 52 (03) :332-339
[7]  
Fetal Medicine Foundation, CERT COMP PREECL SCR
[8]   Restricted fetal growth in sudden intrauterine unexplained death [J].
Froen, JF ;
Gardosi, JO ;
Thurmann, A ;
Francis, A ;
Stray-Pedersen, B .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2004, 83 (09) :801-807
[9]   Utilization of the nuchal translucency image-scoring method during training of new examiners [J].
Herman, A ;
Maymon, R ;
Dreazen, E ;
Zohav, E ;
Segal, O ;
Segal, S ;
Weinraub, Z .
FETAL DIAGNOSIS AND THERAPY, 1999, 14 (04) :234-239
[10]   Nuchal translucency audit: a novel image-scoring method [J].
Herman, A ;
Maymon, R ;
Dreazen, E ;
Caspi, E ;
Bukovsky, I ;
Weinraub, Z .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 12 (06) :398-403