Transient Synchronization Stability Analysis and Enhancement of Paralleled Converters Considering Different Current Injection Strategies

被引:28
作者
Yi, Xiangtong [1 ]
Peng, Yelun [1 ]
Zhou, Quan [1 ]
Huang, Wen [1 ]
Xu, Lijia [1 ]
Shen, Z. John [2 ]
Shuai, Zhikang [1 ]
机构
[1] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
[2] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
基金
中国国家自然科学基金;
关键词
Transient analysis; Phase locked loops; Voltage; Power system stability; Synchronization; Power conversion; Renewable energy sources; grid-connected converters; phase-locked loop (PLL); low voltage ride-through (LVRT); transient synchronization stability; INSTABILITY;
D O I
10.1109/TSTE.2022.3176919
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Renewable energy sources (RESs) are highly penetrated in power systems through phase-locked loop (PLL) synchronized converters. Under severe grid voltage sags, PLL-synchronized RES system is susceptive to transient instability and tripping from the grid due to inappropriate current injection. The existing literatures mainly focus on synchronization instability issues of a single grid-connected RES system, and the effect of the interaction between them is rarely studied. To fill this gap, this paper aims to clarify the interaction mechanism and characterize stability boundary of paralleled PLL-synchronized RES system with different converter parameters. More specifically, the effect of current injection angle and magnitude on transient synchronization stability is investigated for guiding current injection reference design during low voltage ride-through (LVRT) and rated capacity option of RESs. First, the transient interaction model of the paralleled converter system is developed, and interaction mechanism under different current injection angles is revealed. Next, stability region analysis is performed to evaluate the impact of current injection magnitude, wherein current injection boundary is obtained. Then, a current injection design method is proposed for improving both transient stability and voltage support. The theoretical analysis and the proposed method are validated by simulation results.
引用
收藏
页码:1957 / 1968
页数:12
相关论文
共 26 条
[1]   Reconfigurable Control for Fault-Tolerant of Parallel Converters in PMSG Wind Energy Conversion System [J].
Chen, Gen ;
Cai, Xu .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2019, 10 (02) :604-614
[2]   Coupling Mechanism Analysis and Transient Stability Assessment for Multiparalleled Wind Farms During LVRT [J].
Chen, Shiyue ;
Yao, Jun ;
Liu, Yuan ;
Pei, Jinxin ;
Huang, Sen ;
Chen, Zhaoyang .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2021, 12 (04) :2132-2145
[3]   A phase tracking system for three phase utility interface inverters [J].
Chung, SK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :431-438
[4]   Analysis of Phase-Locked Loop Low-Frequency Stability in Three-Phase Grid-Connected Power Converters Considering Impedance Interactions [J].
Dong, Dong ;
Wen, Bo ;
Boroyevich, Dushan ;
Mattavelli, Paolo ;
Xue, Yaosuo .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (01) :310-321
[5]  
E. O. N. Netz, 2006, Grid Code-High and Extra High Voltage
[6]   Instability of Wind Turbine Converters During Current Injection to Low Voltage Grid Faults and PLL Frequency Based Stability Solution [J].
Goksu, Omer ;
Teodorescu, Remus ;
Bak, Claus Leth ;
Iov, Florin ;
Kjaer, Philip Carne .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (04) :1683-1691
[7]   Reduced-Order Models for Representing Converters in Power System Studies [J].
Gu, Yunjie ;
Bottrell, Nathaniel ;
Green, Timothy C. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (04) :3644-3654
[8]   PLL Synchronization Stability of Grid-Connected Multiconverter Systems [J].
He, Xiuqiang ;
Geng, Hua .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (01) :830-842
[9]   Transient Stability Analysis and Enhancement of Renewable Energy Conversion System During LVRT [J].
He, Xiuqiang ;
Geng, Hua ;
Li, Ruiqi ;
Pal, Bikash Chandra .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2020, 11 (03) :1612-1623
[10]   Small Signal Instability of PLL-Synchronized Type-4 Wind Turbines Connected to High-Impedance AC Grid During LVRT [J].
Hu, Jiabing ;
Hu, Qi ;
Wang, Bo ;
Tang, Haiyan ;
Chi, Yongning .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) :1676-1687