Carbon nanotube-coated surface acoustic wave sensor for carbon dioxide sensing

被引:69
作者
Sivaramakrishnana, S. [1 ]
Rajamani, R. [1 ]
Smith, C. S. [2 ]
McGee, K. A. [2 ]
Mann, K. R. [2 ]
Yamashita, N. [3 ]
机构
[1] Univ Minnesota, Dept Mech Engn, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
[3] Univ Arizona, Dept Aerosp & Mech Engn, Tucson, AZ 85721 USA
基金
美国国家科学基金会;
关键词
carbon nanotubes; gas sensing; surface acoustic wave sensors; carbon dioxide;
D O I
10.1016/j.snb.2008.01.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon dioxide gas sensors have been fabricated by self-assembling single-wall nanotube films on a surface acoustic wave delay line operating at 286 MHz. Polymer functionalization was used to enhance the sensitivity of the carbon nanotubes to carbon dioxide. A pulse radar-type interrogation system was used to monitor the conductivity of the nanotube film by measuring the attenuation of the surface acoustic wave due to film-conductivity changes. The conductivity of the film was found to decrease with carbon dioxide concentration. The effect of varying the sheet conductivity of the nanotube film was examined. Both analytical and experimental results show that controlling the conductivity of the CNT film within a specific range highly enhances the sensitivity to carbon dioxide. Experimental results show that the sensor tracks carbon dioxide concentration changes between 0% and 10%. The final sensor is sensitive, small and wirelessly interrogable, thus making it potentially useful for respiratory monitoring. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:296 / 304
页数:9
相关论文
共 33 条
[1]  
[Anonymous], 1990, ACOUSTIC FIELDS WAVE
[2]   Carbon nanotube electronics [J].
Avouris, P ;
Appenzeller, J ;
Martel, R ;
Wind, SJ .
PROCEEDINGS OF THE IEEE, 2003, 91 (11) :1772-1784
[3]  
BurdettSmith P, 1997, BRIT MED J, V314, P1549
[4]   Breath analysis: Potential for clinical diagnosis and exposure assessment [J].
Cao, WQ ;
Duan, YX .
CLINICAL CHEMISTRY, 2006, 52 (05) :800-811
[5]   Properties of a polyethyleneimine-based sensor for measuring medium and high relative humidity [J].
Chachulski, B ;
Gebicki, J ;
Jasinski, G ;
Jasinski, P ;
Nowakowski, A .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (01) :12-16
[6]   Telemetric surface acoustic wave chemical sensors [J].
Fischerauer, G ;
Dickert, FL ;
Sikorski, R .
PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1998, :608-614
[7]   Critical review of non-invasive respiratory monitoring in medical care [J].
Folke, M ;
Cernerud, L ;
Ekström, M ;
Hök, B .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (04) :377-383
[8]   The integration of a chemiresistive film overlay with a surface acoustic wave microsensor [J].
Galipeau, JD ;
LeGore, LJ ;
Snow, K ;
Caron, JJ ;
Vetelino, JF ;
Andle, JC .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) :158-163
[9]   SAW sensors for the room-temperature measurement of CO2 and relative humidity [J].
Hoyt, AE ;
Ricco, AJ ;
Bartholomew, JW ;
Osbourn, GC .
ANALYTICAL CHEMISTRY, 1998, 70 (10) :2137-2145
[10]   Palladium and metal-free phthalocyanine bilayer structures for hydrogen detection in the SAW sensor system based on interaction speed [J].
Jakubik, Wieslaw P. ;
Urbanczyk, Marian W. ;
Maciak, Erwin .
IEEE SENSORS JOURNAL, 2006, 6 (05) :1178-1185