Considerations in Selecting a Fitting a Function for Film Dosimetry in Radiation Therapy

被引:0
|
作者
Hwang, Ui-Jung [1 ]
Kim, Ki Hwan [1 ]
Lim, Young Kyung [2 ]
Kim, Haksoo [2 ]
Choi, Sang Hyoun [3 ]
Min, Byung Jun [4 ]
Jeong, Hojin [5 ]
Rah, Jeong Eun [6 ]
机构
[1] Chungnam Natl Univ Hosp, Dept Radiat Oncol, Daejeon 35015, South Korea
[2] Natl Canc Ctr, Proton Therapy Ctr, Goyang 10408, South Korea
[3] Korea Inst Radiol & Med Sci, Res Ctr Radiotherapy, Seoul 01812, South Korea
[4] Chungbuk Natl Univ Hosp, Dept Radiat Oncol, Cheongju 28644, South Korea
[5] Gyeongsang Natl Univ, Inst Hlth Sci, Dept Radiat Oncol, Jinju 52727, South Korea
[6] Myongji Hosp, Dept Radiat Oncol, Goyang 10475, South Korea
基金
新加坡国家研究基金会;
关键词
Radiation therapy; Quality assurance; EBT3; film; OD to dose calibration; Curve fitting; PORTAL IMAGING DEVICE; FLAT-BED SCANNER; RADIOCHROMIC FILM; EBT FILM; SENSITOMETRIC CURVES; PHOTON; MODEL; CALIBRATION; ELECTRON; PROTOCOL;
D O I
10.3938/jkps.77.94
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Although many technologies, such as an electronic portal imaging device, a software-based quality assurance system, an ion chamber array,etc., have been developed for the purpose of quality assurance of radiotherapy planning, radiochromic film is still one of the most reliable technologies and is being widely used. In particular, compared with other technologies, EBT3 film has unique advantages, including its unlimited spatial resolution, relatively small volume and waterproof quality, which means it can be used inside the patient's body. The main obstacle to using EBT3 film is that various equations have to be used in the calibration process, which makes it very sensitive to the results. The manufacturer provides a fitting function, but many software programs and researchers use their own functions. In this study, some functions normally used for calibrating EBT3 films are compared by analyzing a couple of characteristics in the course of fitting the function to the measured values. Although our study shows the lack of a suitable fitting function that works well in every situation, it can provide valuable insight into selecting suitable functions for fitting in a clinical setting.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 50 条
  • [1] Considerations in Selecting a Fitting a Function for Film Dosimetry in Radiation Therapy
    Ui-Jung Hwang
    Ki Hwan Kim
    Young Kyung Lim
    Haksoo Kim
    Sang Hyoun Choi
    Byung Jun Min
    Hojin Jeong
    Jeong Eun Rah
    Journal of the Korean Physical Society, 2020, 77 : 94 - 101
  • [2] FILM DOSIMETRY IN RADIATION THERAPY
    FEHRENTZ, D
    ZUNTER, F
    STRAHLENTHERAPIE, 1968, 135 (03) : 301 - &
  • [3] Film dosimetry for intensity modulated radiation therapy
    Benites-Rengifo, J
    Martínez-Dávalos, A
    Celis, M
    Lárraga, J
    MEDICAL PHYSICS, 2004, 724 : 244 - 248
  • [4] A filtration method for improving film dosimetry in photon radiation therapy
    Yeo, IJ
    Wang, CKC
    Burch, SE
    MEDICAL PHYSICS, 1997, 24 (12) : 1943 - 1953
  • [5] Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation
    Ju, SG
    Ahn, YC
    Huh, SJ
    Yeo, IJ
    MEDICAL PHYSICS, 2002, 29 (03) : 351 - 355
  • [6] Absolute film dosimetry for verification in intensity modulated radiation therapy
    Mercay, A
    Moeckli, R
    Pache, G
    Bulling, S
    Do, HP
    Bressan, S
    Valley, JF
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 108 - 108
  • [7] Stereotactic Body Radiation Therapy (SBRT) II: Physics and Dosimetry Considerations
    Benedict, S.
    Yenice, K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2858 - +
  • [8] SELECTING RADIOGRAPHIC FILM - CONSIDERATIONS FOR THE SHOP
    BOWLES, W
    MAYBERRY, G
    MATERIALS EVALUATION, 1988, 46 (04) : 426 - 429
  • [9] Selecting for radiation therapy
    Poortmans, Philip
    FUTURE ONCOLOGY, 2017, 13 (08) : 9 - 9
  • [10] Challenges in Radiochromic Film Dosimetry Applied to Microbeam Radiation Therapy (MRT)
    Anderson, D.
    Warkentin, B.
    Siegbahn, E. A.
    Fallone, B. G.
    MEDICAL PHYSICS, 2011, 38 (06)