Cadaveric Simulation of Otologic Procedures: An Analysis of Droplet Splatter Patterns During the COVID-19 Pandemic

被引:20
作者
Sharma, Dhruv [1 ]
Rubel, Kolin E. [1 ]
Ye, Michael J. [1 ]
Campiti, Vincent J. [1 ]
Carroll, Aaron E. [2 ]
Ting, Jonathan Y. [1 ]
Illing, Elisa A. [1 ]
Burgin, Sarah J. [1 ]
机构
[1] Indiana Univ, Dept Otolaryngol Head & Neck Surg, Sch Med, 1130 W Michigan St,Suite 400, Indianapolis, IN 46202 USA
[2] Indiana Univ, Dept Pediat, Indianapolis, IN 46204 USA
关键词
COVID-19; droplets; splatter; myringotomy; mastoidectomy; otologic surgery;
D O I
10.1177/0194599820930245
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective The otolaryngology community has significant concerns regarding the spread of SARS-CoV-2 through droplet contamination and viral aerosolization during head and neck examinations and procedures. The objective of this study was to investigate the droplet and splatter contamination from common otologic procedures. Study Design Cadaver simulation series. Setting Dedicated surgical laboratory. Methods Two cadaver heads were prepped via bilateral middle cranial fossa approaches to the tegmen (n = 4). Fluorescein was instilled through a 4-mm burr hole drilled into the middle cranial fossa floor, and presence in the middle ear was confirmed via microscopic ear examination. Myringotomy with ventilation tube placement and mastoidectomy were performed, and the distribution and distance of resulting droplet splatter patterns were systematically evaluated. Results There were no fluorescein droplets or splatter contamination observed in the measured surgical field in any direction after myringotomy and insertion of ventilation tube. Gross contamination from the surgical site to 6 ft was noted after complete mastoidectomy, though, when performed in standard fashion. Conclusion Our results show that there is no droplet generation during myringotomy with ventilation tube placement in an operating room setting. Mastoidectomy, however, showed gross contamination 3 to 6 ft away in all directions measured. Additionally, there was significantly more droplet and splatter generation to the left of the surgeon when measured at 1 and 3 ft as compared with all other measured directions.
引用
收藏
页码:320 / 324
页数:5
相关论文
共 15 条
  • [1] American Academy of Otolaryngology-Head and Neck Surgery, AC SUPP CMS OFF SPEC
  • [2] American Academy of Otolaryngology-Head and Neck Surgery, OT COVID 19 PAND
  • [3] [Anonymous], COR DIS 2019 COVID 1
  • [4] Airborne or Droplet Precautions for Health Workers Treating Coronavirus Disease 2019?
    Bahl, Prateek
    Doolan, Con
    de Silva, Charitha
    Chughtai, Abrar Ahmad
    Bourouiba, Lydia
    MacIntyre, C. Raina
    [J]. JOURNAL OF INFECTIOUS DISEASES, 2022, 225 (09) : 1561 - 1568
  • [5] A Simple Technique for Droplet Control During Mastoid Surgery
    Carron, Jeffrey D.
    Buck, Lauren S.
    Harbarger, Claude F.
    Eby, Thomas L.
    [J]. JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2020, 146 (07) : 671 - +
  • [6] Centers for Disease Control and Prevention, INF HEALTHC PROF COR
  • [7] FEHR AR, 2015, METHOD MOL BIOL, V1282, DOI DOI 10.1007/978-1-4939-2438-7_1
  • [8] JEWETT DL, 1992, AM IND HYG ASSOC J, V53, P228, DOI 10.1202/0002-8894(1992)053<0228:BAGBST>2.0.CO
  • [9] 2
  • [10] Nosocomial Transmission of Emerging Viruses via Aerosol-Generating Medical Procedures
    Judson, Seth D.
    Munster, Vincent J.
    [J]. VIRUSES-BASEL, 2019, 11 (10):