Investigation of chemical composition of belemnite rostra by synchrotron-based X-ray microfluorescence and diffraction and electron microprobe

被引:9
|
作者
Florek, M
Youn, HS
Ro, CU
Wierzbowski, H
Osán, J
Kazimierczak, W
Kuczumow, A [1 ]
机构
[1] Catholic Univ, Dept Chem, PL-20718 Lublin, Poland
[2] Catholic Univ, Electron Microscopy Lab, PL-20718 Lublin, Poland
[3] KFKI Atom Energy Res Inst, H-1525 Budapest, Hungary
[4] Polish Acad Sci, Inst Geol, Warsaw, Poland
[5] Hallym Univ, Dept Chem, Chunchon 200702, South Korea
[6] Pohang Accelerator Lab, Pohang 790784, South Korea
关键词
belemnites; crystal growth; scanning electron microscopy; X-ray spectroscopies; synchrotron radiation; biomineralization;
D O I
10.1016/S0925-8388(03)00569-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Rostra (bullet-shaped internal shells) of two species of belemnites: Belemnopsis sp. (from Bathonian Stage sediments similar to161-166 Ma ago) and Hibolites sp. (from Middle Oxfordian sediments similar to154-157 Ma) were investigated by the use of 1132 microfluorescence beamline in Pohang Light Source in Korea. The cross-sections of the rostra showed an ordered structure of concentric growth laminae cut across by radial calcite crystals. The inner and outer parts of the cross-section differ in the size of calcite crystals, building the block. Very fine crystals existing in the inner parts of rostra are replaced by monocrystals in their external parts. Some compounds of metallic elements such as iron and zinc are present in the calcite matrices of belemnites. Their presence is especially pronounced in the zones separating particular growth rings. The concentrations of elements in calcite matrix were calibrated by atomic absorption method and the results for alkaline elements are: for Sr similar to1000 ppm for Oxfordian specimen and similar to3000 ppm for Bathonian; for Na, similar to2000 and similar to1400 ppm; for K, similar to160 and similar to100 ppm, respectively. The synchrotron-based investigations were complemented with the electron microprobe search for low-Z elements; using this method sodium, potassium, aluminum, silicon, chlorine and sulfur were detected in the matrix. The variability of molar Mg/Ca ratio follows the optical variability of the annual growth zones of the samples, suggesting that this ratio could be used as a palaeothermometer. Possibilities of both application of the elemental data for the estimation of palaeotemperatures, and cross-checking with the isotopic data are discussed. The substantial amounts of the excess carbon were detected in the samples. They are concluded to be potentially useful for the analysis of remnants of original biological matter. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [31] Investigation of Microfibril Angle of Flax Fibers Using X-Ray Diffraction and Scanning Electron Microscopy
    Wang, Chunhong
    Wang, Ni
    Liu, Shuhan
    Choo-Simth, Lin-P'ing
    Zhang, Hongxia
    Zhi, Zhongxiang
    JOURNAL OF NATURAL FIBERS, 2020, 17 (07) : 1001 - 1010
  • [32] X-Ray Diffraction Studies of Metallic Palladium-Based Foil Filters Using Synchrotron Radiation
    Akimova, O. V.
    Veligzhanin, A. A.
    PHYSICS OF METALS AND METALLOGRAPHY, 2018, 119 (09) : 837 - 841
  • [33] Molecular and crystal structure of poly(tetramethylene adipate) α form based on synchrotron X-ray fiber diffraction
    Noguchi, K
    Kondo, H
    Ichikawa, Y
    Okuyama, K
    Washiyama, J
    POLYMER, 2005, 46 (24) : 10823 - 10830
  • [34] Phase transformations in Ni/Ti multilayers investigated by synchrotron radiation-based x-ray diffraction
    Cavaleiro, A. J.
    Ramos, A. S.
    Martins, R. M. S.
    Fernandes, F. M. Braz
    Morgiel, J.
    Baehtz, C.
    Vieira, M. T.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2015, 646 : 1165 - 1171
  • [35] X-Ray Diffraction Studies of Metallic Palladium-Based Foil Filters Using Synchrotron Radiation
    O. V. Akimova
    A. A. Veligzhanin
    Physics of Metals and Metallography, 2018, 119 : 837 - 841
  • [36] Annealing effect on the chemical composition of a synchrotron radiation irradiated polytetrafluoroethylene (PTFE) surface by the X-ray photoelectron spectroscopy
    Haruyama Y.
    Matsui S.
    Ideta T.
    Ishigaki H.
    IEEJ Transactions on Electronics, Information and Systems, 2010, 130 (10) : 1741 - 1745+5
  • [37] Comparative analysis of sample preparation protocols of soft biological tissues for morphometric studies using synchrotron-based X-ray microtomography
    Dias, Carlos Sato Baraldi
    Amorim Neto, Dionisio Pedro
    Baraldi, Giovanni Lenzi
    Fonseca, Matheus de Castro
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 2013 - 2023
  • [38] Investigation of the microstructure and mineralogical composition of urinary calculi fragments by synchrotron radiation X-ray microtomography: a feasibility study
    Kaiser, Jozef
    Hola, Marketa
    Galiova, Michaela
    Novotny, Karel
    Kanicky, Viktor
    Martinec, Petr
    Scucka, Jiri
    Brun, Francesco
    Sodini, Nicola
    Tromba, Giuliana
    Mancini, Lucia
    Koristkova, Tamara
    UROLOGICAL RESEARCH, 2011, 39 (04): : 259 - 267
  • [39] Investigation of the microstructure and mineralogical composition of urinary calculi fragments by synchrotron radiation X-ray microtomography: a feasibility study
    Jozef Kaiser
    Markéta Holá
    Michaela Galiová
    Karel Novotný
    Viktor Kanický
    Petr Martinec
    Jiří Ščučka
    Francesco Brun
    Nicola Sodini
    Giuliana Tromba
    Lucia Mancini
    Tamara Kořistková
    Urological Research, 2011, 39 : 259 - 267
  • [40] CHARACTERIZATION OF ELECTRONIC STRUCTURES AT ORGANIC-2D MATERIALS INTERFACES WITH ADVANCED SYNCHROTRON-BASED SOFT X-RAY SPECTROSCOPY
    Cao, Liang
    Qi, Dong-Chen
    SURFACE REVIEW AND LETTERS, 2021, 28 (08)