Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacement

被引:130
作者
Markl, M
Draney, MT
Miller, DC
Levin, JM
Williamson, EE
Pelc, NJ
Liang, DH
Herfkens, RJ
机构
[1] Stanford Univ, Dept Radiol, Lucas MRI S Ctr, Palo Alto, CA 94304 USA
[2] Stanford Univ, Dept Mech Engn, Palo Alto, CA 94304 USA
[3] Stanford Univ, Dept Cardiothorac Surg, Palo Alto, CA 94304 USA
[4] Stanford Univ, Div Cardiovasc Med, Palo Alto, CA 94304 USA
关键词
D O I
10.1016/j.jtcvs.2004.08.056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To provide more complete characterization of ascending aortic blood flow, including vortex formation behind the valve cusps, in healthy subjects and patients after valve-sparing aortic root replacement (David reimplantation). Methods: Time-resolved 3-dimensional magnetic resonance imaging velocity mapping was performed to analyze pulsatile blood flow by using encoded 3-directional vector fields in the thoracic aortas of 10 volunteers and 12 patients after David reimplantation using a cylindrical tube graft (T. David 1) and two versions of neosinus recreation (T. David-V and T. David-V-S-mod). Aortic flow was evaluated by using 3-dimensional time-resolved particle traces and velocity vector fields reformatted onto 2-dimensional planes. Semiquantitative data were derived by using a blinded grading system (0-3: 0, none; 1, minimal; 2, medium; 3, prominent) to analyze the systolic vortex formation behind the cusps, as well as retrograde and helical flow in the ascending aorta. Results: Systolic vortices were seen in both coronary sinuses of all volunteers (greater in the left sinus [2.5 +/- 0.5] than the right [1.8 +/- 0.8]) but in only 4 of 10 noncoronary sinuses (0.7 +/- 0.9). Comparable coronary vortices were detected in all operated patients. Vorticity was minimal in the noncoronary cusp in T. David-I repairs (0.7 +/- 0.7) but was prominent in T. David-V noncoronary graft pseudosinuses (1.5 +/- 0.6; P = .035). Retrograde flow (P = .001) and helicity (P = .028) were found in all patients but were not distinguishable from normal values in the T. David-V-Smod patients. Conclusions: Coronary cusp vorticity was preserved after David reimplantation, regardless of neosinus creation. Increased retrograde flow and helicity were more prominent in T. David-V patients. These novel magnetic resonance imaging methods can assess the clinical implications of altered aortic flow dynamics in patients undergoing various types of valve-sparing aortic root replacement.
引用
收藏
页码:456 / 463
页数:8
相关论文
共 29 条
[1]   MECHANISM OF CLOSURE OF AORTIC VALVE [J].
BELLHOUSE, BJ ;
BELLHOUSE, FH .
NATURE, 1968, 217 (5123) :86-+
[2]  
Bogren HG, 1999, J MAGN RESON IMAGING, V10, P861, DOI 10.1002/(SICI)1522-2586(199911)10:5<861::AID-JMRI35>3.0.CO
[3]  
2-E
[4]   Visualizing blood flow patterns using streamlines, arrows, and particle paths [J].
Buonocore, MH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) :210-226
[5]   Results of aortic valve-sparing operations [J].
David, TE ;
Armstrong, S ;
Ivanov, J ;
Feindel, CM ;
Omran, A ;
Webb, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (01) :39-46
[6]  
DAVID TE, 1992, J THORAC CARDIOV SUR, V103, P617
[7]   Results of surgery for aortic root aneurysm in patients with Marfan syndrome [J].
de Oliveira, NC ;
David, TE ;
Ivanov, J ;
Armstrong, S ;
Eriksson, MJ ;
Rakowski, H ;
Webb, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (04) :789-796
[8]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241
[9]   Three dimensional flow in the human left atrium [J].
Fyrenius, A ;
Wigström, L ;
Ebbers, T ;
Karlsson, M ;
Engvall, J ;
Bolger, AF .
HEART, 2001, 86 (04) :448-455
[10]   Contemporary cardiac imaging - An overview [J].
Goldin, JG ;
Ratib, O ;
Aberle, DR .
JOURNAL OF THORACIC IMAGING, 2000, 15 (04) :218-229