An investigation of optimum PV and wind energy system capacities for alternate short and long-term energy storage sizing methodologies

被引:34
作者
Al-Ghussain, Loiy [1 ]
Taylan, Onur [2 ]
Baker, Derek K. [3 ]
机构
[1] Middle East Tech Univ, Sustainable Environm & Energy Syst, Northern Cyprus Campus,Guzelyurt Via Mersin 10, TR-99738 Kalkanli, Turkey
[2] Middle East Tech Univ, Mech Engn Program, Northern Cyprus Campus,Guzelyurt Via Mersin 10, TR-99738 Kalkanli, Turkey
[3] Middle East Tech Univ, Dept Mech Engn, TR-06800 Ankara, Turkey
基金
欧盟地平线“2020”;
关键词
battery; energy storage system; hybrid energy systems; pumped hydro storage; PV systems; wind systems; HYBRID; BATTERY; OPTIMIZATION; ISLAND; ELECTRIFICATION; CONFIGURATIONS; SIMULATION; MODEL;
D O I
10.1002/er.4251
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The goal of this study is to find the optimal sizes of renewable energy systems (RES) based on photovoltaic (PV) and/or wind systems for three energy storage system (ESS) scenarios in a micro-grid; (1) with pumped hydro storage (PHS) as a long-term ESS, (2) with batteries as a short-term ESS, and (3) without ESS. The PV and wind sizes are optimally determined to accomplish the maximum annual RES fraction (F-RES) with electricity cost lower than or equal to the utility tariff. Furthermore, the effect of the use of battery and PHS on the electricity cost and F-RES are studied. A university campus on a Mediterranean island is selected as a case study. The results show that PV-wind hybrid system of 8 MW wind and 4.2 MW PV with 89.5 MWh PHS has the highest F-RES of 88.0%, and the highest demand supply fraction as 42.6%. Moreover, the results indicate that the economic and technical parameters of RESs are affected significantly by the use of ESSs depending on the type and the capacity of both the RES and the ESS.
引用
收藏
页码:204 / 218
页数:15
相关论文
共 50 条
[1]   Techno-economic optimization of hybrid power system using genetic algorithm [J].
Al-Shamma'a, Abdullrahman A. ;
Addoweesh, Khaled E. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2014, 38 (12) :1608-1623
[2]  
Alsaidan I, NAPS 2016 48 N AM PO, DOI [10. 1109/NAPS. 2016. 7747845 ., DOI 10.1109/NAPS.2016.7747845]
[3]  
[Anonymous], WIND
[4]   Optimised model for community-based hybrid energy system [J].
Ashok, S. .
RENEWABLE ENERGY, 2007, 32 (07) :1155-1164
[5]  
Atkins P., 2005, SAFEGUARDING OZONE L
[6]  
AXITEC Solar, 2015, AXIPLUS SE 60
[7]   Reliability-Constrained Optimal Sizing of Energy Storage System in a Microgrid [J].
Bahramirad, Shaghayegh ;
Reder, Wanda ;
Khodaei, Amin .
IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (04) :2056-2062
[8]   An overview of the environmental, economic, and material developments of the solar and wind sources coupled with the energy storage systems [J].
Balali, Mohammad Hasan ;
Nouri, Narjes ;
Omrani, Emad ;
Nasiri, Adel ;
Otieno, Wilkistar .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2017, 41 (14) :1948-1962
[9]   Simulation and optimization of stand-alone hybrid renewable energy systems [J].
Bernal-Agustin, Jose L. ;
Dufo-Lopez, Rodolfo .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (08) :2111-2118
[10]   A novel off-grid hybrid power system comprised of solar photovoltaic, wind, and hydro energy sources [J].
Bhandari, Binayak ;
Lee, Kyung-Tae ;
Lee, Caroline Sunyong ;
Song, Chul-Ki ;
Maskey, Ramesh K. ;
Ahn, Sung-Hoon .
APPLIED ENERGY, 2014, 133 :236-242