A Real-Time Energy Management System Design for a Developed PV-Based Distributed Generator Considering the Grid Code Requirements in Turkey

被引:3
作者
Bayrak, Gokay [1 ]
Ertekin, Davut [1 ]
Haes Alhelou, Hassan [2 ,3 ]
Siano, Pierluigi [4 ,5 ]
机构
[1] Bursa Tech Univ, Elect & Elect Engn Dept, TR-16310 Bursa, Turkey
[2] Univ Coll Dublin, Sch Elect & Elect Engn, Dublin D04 V1W8, Ireland
[3] RMIT Univ, Sch Engn, 124 La Trobe St, Melbourne, Vic 3000, Australia
[4] Univ Salerno, Dept Management & Innovat Syst, I-84084 Salerno, Italy
[5] Univ Johannesburg, Dept Elect & Elect Engn Sci, ZA-2028 Johannesburg, South Africa
关键词
grid code; energy management; distributed generation; PV system; islanding detection; ISLANDING DETECTION; INSTALLATION;
D O I
10.3390/en14206684
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Each country must determine the Grid Code conditions and apply these criteria to integrate distributed generation (DG) systems into the existing electricity grid and to ensure a stable power system. Thus, experimental studies are required to provide an effective, national, and specific Grid Code. In this study, the Turkish Grid Code's electrical criteria were examined, and the application of these criteria was carried out on a developed PV-based DG. A real-time energy management system (RTEMS) was proposed in the study. Electrical parameters on the developed DG were monitored in real-time by considering IEEE 1547, IEEE 929-2000, and Turkey's electrical criteria. A practical grid code study was firstly investigated in detail about the Turkish Grid Code by a developed real-time monitoring-control and protection system. The proposed RTEMS method in the study is implemented as an inverter-resident system; thus, it provides advantages over many energy management systems embedded in the inverter. The degradation in power quality and non-detection zone (NDZ) problems encountered in active and passive island mode detection methods developed embedded in the inverter are eliminated in the proposed method. With the RTEMS method, where under and over-voltage, under and over voltage frequency, and unintentional island mode events can be detected in real-time, both the existing grid-code requirements are met, and the existing power quality and NDZ problem is eliminated with the recommended inverter-independent RTEMS method.
引用
收藏
页数:21
相关论文
共 52 条
[1]  
Abobakr H., 2021, J ADV ENG TRENDS, V40, P79, DOI [10.21608/jaet.2021.82233, DOI 10.21608/JAET.2021.82233]
[2]  
Aghdam FH, 2020, POWER SYST, P69, DOI 10.1007/978-3-030-23723-3_4
[3]   Solar radiation over Turkey and its analysis [J].
Aksoy, Bulent .
INTERNATIONAL JOURNAL OF REMOTE SENSING, 2011, 32 (21) :6261-6272
[4]  
[Anonymous], 2014, INT J ENERGY EC POLI
[5]  
[Anonymous], 2009, 15472 IEEE
[6]  
[Anonymous], 2011, 505492 CLCFPRTS
[7]  
[Anonymous], 2007, 50438 BS EN
[8]  
[Anonymous], 2007, ENV IMPACTS WIND ENE, P1
[9]  
[Anonymous], 2013, PRIORITIZATION TECHN
[10]  
[Anonymous], 2011, 4105 VDEARN