Direct determination of cadmium in calcium drug samples using electrothermal atomic absorption spectrometry with a metal tube atomizer and thiourea as a matrix modifier

被引:17
作者
Ahsan, S [1 ]
Kaneco, S
Ohta, K
Mizuno, T
Taniguchi, Y
机构
[1] Mie Univ, Fac Engn, Dept Chem Mat, Tsu, Mie 51485, Japan
[2] Mie Ind Res Inst, Tsu, Mie 5140008, Japan
关键词
cadmium; direct atomization; drug sample; electrothermal atomization; molybdenum tube atomizer;
D O I
10.1016/S0039-9140(98)00226-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A laboratory constructed molybdenum tube atomizer was used for direct determination of trace cadmium in drug samples by the electrothermal atomic absorption spectrometric (ETAAS) method. An ultrasonic agitation method for a solution including the sample powder was used. A calibration curve was constructed with a cadmium standard solution including matrix. To eliminate interference from other matrix elements, a chemical modifier thiourea, was used. The detection limit were 17 pg ml(-1) (3 S/N), and the RSD of the direct analysis was 5-17%. The results for cadmium in the four drug samples analysed by the direct ETAAS method matched well with those obtained with nitric acid digested samples. The recovery of added cadmium was 103-106%. An accurate method is elaborated for the determination of cadmium in drug samples by direct ETAAS techniques. The merits of this method are rapid calibration, simplicity, fast analysis, and low cost. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [31] Rapid determination of selenium, lead and cadmium in baby food samples using electrothermal atomic absorption spectrometry and slurry atomization
    Viñas, P
    Pardo-Martínez, M
    Hernández-Córdoba, M
    ANALYTICA CHIMICA ACTA, 2000, 412 (1-2) : 121 - 130
  • [32] Rapid determination of lead and cadmium in sewage sludge samples using electrothermal atomic absorption spectrometry with slurry sample introduction
    I. López-García
    P. Viñas
    J. Arroyo-Cortéz
    M. Hernández-Córdoba
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 727 - 732
  • [33] Determination of cadmium in slurries of marine sediment samples by electrothermal atomic absorption spectrometry using palladium and phosphate as chemical modifiers
    BermejoBarrera, P
    BarcielaAlonso, C
    BermejoBarrera, A
    MIKROCHIMICA ACTA, 1996, 124 (3-4) : 251 - 261
  • [34] Rapid determination of lead and cadmium in biological fluids by electrothermal atomic absorption spectrometry using Zeeman correction
    Campillo, N
    Viñas, P
    López-García, I
    Hernández-Córdoba, M
    ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) : 207 - 215
  • [35] The determination of the contamination level with lead and cadmium in sweet food samples by atomic absorption spectrometry with electrothermal atomization
    Alexiu, V
    Vladescu, L
    REVISTA DE CHIMIE, 2003, 54 (07): : 557 - 560
  • [36] Determination of Trace Cadmium in Food Samples by Electrothermal Atomic Absorption Spectrometry After Cloud Point Extraction
    Xiang, G. Q.
    Wen, S. P.
    Wu, X. Y.
    Liu, Y. L.
    Jiang, X. M.
    He, L. J.
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (04) : 1548 - 1552
  • [37] Determination of lead and cadmium in urine by electrothermal atomization atomic absorption spectrometry
    L. A. Vasil’eva
    I. L. Grinshtein
    S. Gucer
    B. Izgi
    Journal of Analytical Chemistry, 2008, 63 : 649 - 654
  • [38] Simultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometry
    Freschi, GPG
    Dakuzaku, CS
    de Moraes, M
    Nóbrega, JA
    Neto, JAG
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) : 1987 - 1993
  • [39] Aluminium as chemical modifier for the determination of lead in sugar cane spirits using electrothermal atomic absorption spectrometry
    Ferreira, Sergio Luis Costa
    Portugal, Lindomar Andrade
    Matos, Geraldo Domingues
    da Silva, Douglas Goncalves
    de Jesus, Robson Mota
    Brito, Geysa Barreto
    ANALYTICAL METHODS, 2011, 3 (05) : 1168 - 1171
  • [40] Determination of Metal Impurities in Carbon Nanotubes by Direct Solid Sampling Electrothermal Atomic Absorption Spectrometry
    Mello, Paola A.
    Rodrigues, Luiz Frederico
    Nunes, Matheus A. G.
    Mattos, Julio Cezar P.
    Mueller, Edson I.
    Dressler, Valderi L.
    Flores, Erico M. M.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (06) : 1040 - U62