摘要
Objective: Valvuloplasty of the aortic valve is currently used in selected patients for severe calcified aortic valve disease, but clinical effectiveness is low and complication rate remains high. In this study, the total particle load after valvuloplasty and the embolization risk of calcific debris into the coronary arteries was analyzed in an in vitro model. Methods: Three highly calcified human aortic leaflets have been sutured into a porcine annulus (N = 9). Both coronary arteries were separated and each was anastomized to a silicon line, which was drained off into a measuring beaker. Then valvuloplasty was performed (Thyshak II, 20 mm, 1.5 atm). After removal of the balloon, 100 ml of sodium chloride solution irrigated the ascending aorta. After passing through the separated coronary arteries, the solution was filtered (filter size 0.45 mu m), dried, and the total amount of particles was analyzed microscopically. Results: Nine experiments were analyzed. After valvuloplasty, all hearts showed a median of 18 particles larger than 1 mm in the coronary arteries (range 0-307). The amount of particles smaller than 1 mm was 6574 (median, range 2207-14200). In five cases, coronary arteries were completely occluded by bulky particles. Conclusion: This study demonstrated a large amount of calcific particles after valvuloplasty with a consequently high risk for coronary embolic events in case of highly calcified aortic valves. In times of valvuloplasty rediscovering as part of transcatheter valve implantation, the risk of embolization should be taken into consideration and filtering techniques have to be developed. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.
引用
收藏
页码:631 / 634
页数:4
相关论文
共 17 条
[1]   Unexpected Complications of Transapical Aortic Valve Implantation [J].
Al-Attar, Nawwar ;
Ghodbane, Walid ;
Himbert, Dominique ;
Rau, Cederic ;
Raffoul, Richard ;
Messika-Zeitoun, David ;
Brochet, Eric ;
Vahanian, Alec ;
Nataf, Patrick .
ANNALS OF THORACIC SURGERY, 2009, 88 (01) :90-94
[2]   Results of percutaneous and transapical transcatheter aortic valve implantation performed by a surgical team [J].
Bleiziffer, Sabine ;
Ruge, Hendrik ;
Mazzitelli, Domenico ;
Schreiber, Christian ;
Hutter, Andrea ;
Laborde, Jean-Claude ;
Bauernschmitt, Robert ;
Lange, Ruediger .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (04) :615-621
[3]   Intraluminal aortic manipulation by means of intra-aortic filter, cannulation, and external clamp maneuvers evaluated versus dislodged embolic material [J].
Boivie, P ;
Hansson, M ;
Engström, KG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (02) :283-289
[4]   Percutaneous aortic valve replacement: computed tomography scan after valved stent implantation in human cadaver hearts [J].
Bombien, Rene ;
Huemme, Tim ;
Schuenke, Michael ;
Lutter, Georg .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 36 (03) :592-594
[5]   Percutaneous aortic valve replacement: gross anatomy and histological findings after transapical and endoluminal resection of human aortic valves in situ [J].
Bombien, Rene Hubert ;
Appel, Marie ;
Attmann, Tim ;
Klaws, Guenter-Rudolf ;
Schuenke, Michael ;
Hass, Christine ;
Cremer, Jochen ;
Lutter, Georg .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 36 (01) :112-117
[6]  
Christenson JT, 2005, TEX HEART I J, V32, P515
[7]   Review on balloon aortic valvuloplasty: a surgeon's perspective in 2008 [J].
Conradi, Lenard ;
Reichenspurner, Hermann .
CLINICAL RESEARCH IN CARDIOLOGY, 2008, 97 (05) :285-287
[8]  
DREWS T, 2009, THORAC CARDIOVASC S1, V56, pS34
[9]   Particulate emboli capture by an intra-aortic filter device during aortic valve replacement [J].
Leite Filho, Osanan Amorim ;
de Almeida Brandao, Carlos Manuel ;
Alberto Pomerantzeff, Pablo Maria ;
Vieira Guedes, Marco Antonio ;
Higuchi, Maria de Lourdes ;
Groppo Stolf, Noedir Antonio .
REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2008, 23 (03) :431-435
[10]   Percutaneous valve replacement: Current state and future prospects [J].
Lutter, G ;
Ardehali, R ;
Cremer, J ;
Bonhoeffer, P .
ANNALS OF THORACIC SURGERY, 2004, 78 (06) :2199-2206