Surface structure feature matching algorithm for cardiac motion estimation

被引:4
|
作者
Zhang, Zhengrui [1 ]
Yang, Xuan [2 ]
Tang, Cong [2 ]
Guo, Wei [2 ]
Chen, Guoliang [2 ]
机构
[1] Shenzhen Univ, Coll Informat Engn, Shenzhen 518060, Peoples R China
[2] Shenzhen Univ, Coll Comp Sci & Software Engn, Shenzhen 518060, Peoples R China
来源
BMC MEDICAL INFORMATICS AND DECISION MAKING | 2017年 / 17卷
基金
中国国家自然科学基金;
关键词
Gaussian mixture model; Surface structure feature; Point set matching; Stochastic gradient descent; REGISTRATION; SEGMENTATION; DEFORMATION; MRI;
D O I
10.1186/s12911-017-0560-z
中图分类号
R-058 [];
学科分类号
摘要
Background: Cardiac diseases represent the leading cause of sudden death worldwide. During the development of cardiac diseases, the left ventricle (LV) changes obviously in structure and function. LV motion estimation plays an important role for diagnosis and treatment of cardiac diseases. To estimate LV motion accurately for cine magnetic resonance (MR) cardiac images, we develop an algorithm by combining point set matching with surface structure features of myocardium. Methods: The structure features of myocardial wall are described by estimating the normal directions of points locating on the myocardium contours using an approximation approach. The Gaussian mixture model (GMM) of structure features is used to represent LV structure feature distribution. A new cost function is defined to represent the differences between two Gaussian mixture models, which are the GMM of structure features and the GMM of positions of two point sets. To optimize the cost function, its gradient is derived to use the Quasi-Newton (QN). Furthermore, to resolve the dis-convergence issue of Quasi-Newton for high-dimensional parameter space, Stochastic Gradient Descent (SGD) is used and SGD gradient is derived. Finally, the new cost function is solved by optimization combining SGD with QN. With the closed form expression of gradient, this paper provided a computationally efficient registration algorithm. Results: Three public datasets are employed to verify the performance of our algorithm, including cardiac MR image sequences acquired from 33 subjects, 14 inter-subject heart cases, and the data obtained in MICCAI 2009s 3D Segmentation Challenge for Clinical Applications. We compare our results with those of the other point set registration methods for LV motion estimation. The obtained results demonstrate that our algorithm shows inherent statistical robustness, due to the combination of SGD and Quasi-Newton optimization. Furthermore, our method is shown to outperform other point set matching methods in the registration accuracy. Conclusions: We provide a novel effective algorithm for cardiac motion estimation by introducing LV surface structure feature to point set matching. A new cost function is defined to measure the discrepancy between GMMs of two point sets. The GMM of point positions and the GMM of surface structure descriptor are defined at the same time. Optimization by combining SGD and Quasi-Newton is performed to solve the cost function. We experimentally demonstrate that our algorithm shows improved registration accuracy, and is convergent when used in high-dimensional parameter space.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Anisotropic non-rigid Iterative Closest Point Algorithm for respiratory motion abdominal surface matching
    Spinczyk, Dominik
    Bas, Mateusz
    BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (1)
  • [12] Deformable cardiac surface tracking by adaptive estimation algorithms
    Tuna, E. Erdem
    Franson, Dominique
    Seiberlich, Nicole
    Cavusoglu, M. Cenk
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [13] Left Ventricle Motion Estimation in Cine MRI With multilayer Iterative Deformable Graph Matching
    Zhang, Zhengrui
    Yang, Xuan
    Wu, Junhao
    Chen, Guoliang
    IEEE ACCESS, 2019, 7 : 34791 - 34806
  • [14] A Star Image Registration Algorithm based on Joint Feature Matching
    Li, Zhao
    Wen, Yan
    AOPC 2017: OPTICAL SENSING AND IMAGING TECHNOLOGY AND APPLICATIONS, 2017, 10462
  • [15] An Adaptive Clustering Algorithm for Image Matching Based on Corner Feature
    Wang, Zhe
    Dong, Min
    Mu, Xiaomin
    Wang, Song
    NINTH INTERNATIONAL CONFERENCE ON GRAPHIC AND IMAGE PROCESSING (ICGIP 2017), 2018, 10615
  • [16] Anatomy-Aware Cardiac Motion Estimation
    Chen, Pingjun
    Chen, Xiao
    Chen, Eric Z.
    Yu, Hanchao
    Chen, Terrence
    Sun, Shanhui
    MACHINE LEARNING IN MEDICAL IMAGING, MLMI 2020, 2020, 12436 : 150 - 159
  • [17] Joint cardiac and respiratory motion estimation for motion-corrected cardiac PET-MR
    Kolbitsch, Christoph
    Neji, Radhouene
    Fenchel, Matthias
    Schuh, Andreas
    Mallia, Andrew
    Marsden, Paul
    Schaeffter, Tobias
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (01)
  • [18] Revised Motion Estimation Algorithm for PROPELLER MRI
    Pipe, James G.
    Gibbs, Wende N.
    Li, Zhiqiang
    Karis, John P.
    Schar, Michael
    Zwart, Nicholas R.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 430 - 437
  • [19] Remote Sensing Multimodal Image Matching Based on Structure Feature and Learnable Matching Network
    Han, Songlai
    Liu, Xuesong
    Dong, Jing
    Liu, Haiqiao
    APPLIED SCIENCES-BASEL, 2023, 13 (13):
  • [20] A fully convolutional network feature descriptor: Application to left ventricle motion estimation based on graph matching in short-axis MRI
    Wu, Junhao
    Gan, Ziyu
    Guo, Wei
    Yang, Xuan
    Lin, Adan
    NEUROCOMPUTING, 2020, 392 : 196 - 208