Retinal Toxicity of Medical Devices Used during Vitreoretinal Surgery: A Critical Overview

被引:34
|
作者
Januschowski, Kai [1 ,2 ]
Irigoyen, Cristina [3 ]
Pastor, J. Carlos [4 ,5 ,6 ,7 ]
Srivastava, Girish K. [4 ,7 ]
Romano, Mario R. [8 ,9 ]
Heimann, Heinrich [10 ]
Stalmans, Peter [11 ]
Van Keer, Karel [11 ]
Boden, Karl [1 ]
Szurman, Peter [1 ,2 ]
Spitzer, Martin S. [12 ]
机构
[1] Knappschaftshops Sulzbach Saar, Eye Clin Sulzbach, Sulzbach, Germany
[2] Univ Eye Hosp Tubingen, Ctr Ophthalmol, Tubingen, Germany
[3] Donostia Univ Hosp, Ophthalmol Dept, Donostia San Sebastian, Spain
[4] Univ Valladolid, Eye Inst, IOBA, Campus Miguel Delibes, Valladolid, Spain
[5] Hosp Clin Univ, Dept Ophthalmol, Valladolid, Spain
[6] Minist Econ & Competitividad, Oftared Red Temat Invest Oftalmol Inst Salud Carl, Madrid, Spain
[7] Junta Castilla & Leon, Ctr Red Terapia Celular & Med Regenerat Castilla, Valladolid, Spain
[8] Humanitas Univ, Dept Biomed Sci, Rozzano Milan, Italy
[9] Humanitas Clin Gavazzeni, Humanitas Gavazzeni, Eye Ctr, Bergamo, Italy
[10] Royal Liverpool Univ Hosp, Ctr Ophthalmol, Liverpool, Merseyside, England
[11] Univ Hosp Leuven, Dept Ophthalmol, Leuven, Belgium
[12] Univ Med Ctr Hamburg Eppendorf UKE, Dept Ophthalmol, Hamburg, Germany
关键词
Retinal toxicity; Toxicity testing; Vitrectomy; Silicone oil toxicity; Heavy liquid toxicity; Vital dye toxicity; Intraocular surgery medical devices; ISO; 10993; norm; SILICONE OIL; PERFLUOROCARBON LIQUIDS; INDOCYANINE GREEN; VITREOUS SURGERY; RISK-FACTOR; IN-VITRO; VITRECTOMY; DAMAGE; ACID; EMULSIFICATION;
D O I
10.1159/000488504
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Retinal toxicity/biocompatibility of medical devices in direct contact with the retina is an important subject for clinicians and scientists. As these effects are not very frequent, there is also a relative lack of information for many clinicians. The past has taught us multiple times that there is a significant safety problem associated with severe loss of vision in affected patients. In this review, we want to classify medical products that are used in the back of the eye, describe recent examples of toxicity, critically reflect on the regulations that exist and suggest improvements that can be done to ensure patient safety without hindering innovation. Methods: Critical review of the recent papers and personal experience of the authors in this issue. Medical devices used in the back of the eye and recent examples of toxicity are described, regulations that exist are critically reflected and improvements suggested that can ensure patient safety without hindering innovation. Results: There is clear evidence of toxicity after intraocular surgery in any category. Some cytotoxic indirect methods have failed in detecting this toxicity. Some ISO rules do not seem appropriate. Postmarketing safety is missing. There is little data on this issue. Conclusions: The absence of a clear regulation of the production, purification and evaluation of the toxic effects of the medical devices supposes the possibility that products are not sufficiently safe to obtain the CE mark.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 29 条
  • [21] Comparison of five different thermometry devices used during laparoscopic surgery and intensive care treatment: An observational study
    Lindholm, E.
    Bjorlin, C.
    Thorsen, K.
    Ringdal, K. G.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2023, 67 (04) : 552 - 553
  • [22] TOXICITY OF PLASTICS USED IN MEDICAL PRACTICE .1. INVESTIGATION OF TISSUE RESPONSE IN ANIMALS BY CERTAIN UNIT PACKAGED POLYVINYL CHLORIDE ADMINISTRATION DEVICES
    LAWRENCE, WH
    GUESS, WL
    MITCHELL, JL
    AUTIAN, J
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1963, 52 (10) : 958 - &
  • [23] Novel antimicrobial materials designed for the 3D printing of medical devices used during the COVID-19 crisis
    Furka, Samuel
    Furka, Daniel
    Dadi, Nitin Chandra Teja Chandra Teja
    Palacka, Patrik
    Hromnikova, Dominika
    Duenas Santana, Julio Ariel
    Pineda, Javier Diaz
    Casas, Saul Duenas
    Bujdak, Juraj
    RAPID PROTOTYPING JOURNAL, 2021, 27 (05) : 890 - 904
  • [24] Reprocessing and reuse of single-use medical devices used during hemodynamic procedures in Brazil: A widespread and largely overlooked problem
    Buchdid Amarante, Jorge M.
    Toscano, Cristiana M.
    Pearson, Michele L.
    Roth, Virginia
    Jarvis, William R.
    Levin, Anna S.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2008, 29 (09): : 854 - 858
  • [25] Regulatory Considerations for Physiological Closed-Loop Controlled Medical Devices Used for Automated Critical Care: Food and Drug Administration Workshop Discussion Topics
    Parvinian, Bahram
    Scully, Christopher
    Wiyor, Hanniebey
    Kumar, Allison
    Weininger, Sandy
    ANESTHESIA AND ANALGESIA, 2018, 126 (06): : 1916 - 1925
  • [26] Recovery From a Myocardial Infarction Is Impaired in Male C57bl/6N Mice Acutely Exposed to the Bisphenols and Phthalates That Escape From Medical Devices Used in Cardiac Surgery
    Shang, Jijun
    Corriveau, Jeanne
    Champoux-Jenane, Alexandre
    Gagnon, Julie
    Moss, Emmanuel
    Dumas, Pierre
    Gaudreau, Eric
    Chevrier, Jonathan
    Chalifour, Lorraine E.
    TOXICOLOGICAL SCIENCES, 2019, 168 (01) : 78 - 94
  • [27] Health care professionals most relevant phrases used in a digital medical translation tool in 24-7 communication with minority speaking heart surgery patients during hospitalization
    Lie, I.
    Rokeness, S.
    Hasle, C. H.
    Johannsen, N.
    Skredsvik, K.
    Nes, L. S.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [28] IS PARTICIPATION IN INSURANCE-MANDATED MEDICAL WEIGHT MANAGEMENT PROGRAM ASSOCIATED REDUCED INPATIENT RESOURCE UTILIZATION DURING THE FIRST POSTOPERATIVE YEAR FOLLOWING BARIATRIC SURGERY A critical review of the need, or lack thereof, of preoperative weight loss
    Gasoyan, H.
    Sarwer, D.
    Soans, R.
    Ibrahim, J.
    Aaronson, W.
    OBESITY SURGERY, 2022, 32 (SUPPL 2) : 314 - 314